Inspection history · 44
22 May 2026
Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8378361
25 September 2025
ACP COI Oversight · Re-Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8241441
10 April 2025
ISM SMC Audit · TPO Audit
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8111179
13 December 2024
Annual Inspection · ACP Annual Oversight
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8046220
22 October 2024
Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8029801
4 September 2024
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7995789
27 November 2023
ACP Periodic Oversight · Periodic Inspection · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7830097
19 July 2023
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7746949
6 May 2023
Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7682148
28 November 2022
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7600634
16 December 2021
ACP Annual Oversight · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7369396
16 February 2021
Administrative Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7141346
16 February 2021
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7142342
28 December 2020
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7117441
6 October 2020
Re-Inspection · MTSA/ISPS Verification · ACP COI Oversight
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7069597
20 March 2020
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6929697
6 February 2020
Annual Inspection · ACP Annual Oversight
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6897263
20 February 2019
ACP Annual Oversight · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6629312
23 August 2018
MTSA/ISPS Verification · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6519962
19 December 2017
Annual Inspection · ACP Annual Oversight
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6324013
17 July 2017
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6213132
6 December 2016
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6050592
20 November 2015
COI Inspection · Internal Structural Exam · ACP Handover Survey · Drydock Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5760223
2 September 2015
MARPOL Annex I Examination · MARPOL Annex V Examination · Annual Inspection · Ballast Water Examination · Administrative Inspection · MTSA/ISPS Verification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5231179
27 August 2015
Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5728053
31 March 2015
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5093798
11 September 2014
MTSA Verification
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4981495
27 June 2014
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4905668
14 May 2014
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4858895
14 May 2014
Examination of Repairs · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4862191
14 May 2014
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4863287
5 May 2014
Annual Inspection · Welding Related Inspections Qualification Testing · MARPOL Annex I Examination · MTSA/ISPS Verification · MARPOL Annex VI Survey · Internal Structural Exam · Administrative Inspection · Hull Examination · Drydock Exam · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4847911
7 March 2014
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 4813180
17 September 2013
COI Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 4730795
30 July 2012
Annual Inspection · Administrative Inspection · DAPI Audit
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4396487
13 July 2012
Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4377314
26 June 2012
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4357387
6 January 2012
Damage Survey
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4222156
9 November 2011
Deficiency Check · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4186127
3 November 2011
Deficiency Check · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4181588
28 September 2011
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4156661
11 August 2011
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4112189
15 July 2011
In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4082800
1 July 2011
MARPOL Annex I Examination · MTSA/ISPS Verification · Initial Construction-Excluding Oversight · MARPOL Annex V Examination · MARPOL Annex IV Survey · Initial Certification
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4060853
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 4 September 2024
Resolved
The machinery, boilers and other pressure vessels, associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended.
Vessel reported a loss of propulsion of the starboard main engine. Provide class report attesting to satisfactory repairs and operational testing of starboard main engine to the satisfaction of class and CG. - 74 SOLAS (20) II-1/26.1
Action required: 60 - Rectify deficiencies prior to movement
Due 5 September 2024
Resolved 5 September 2024
Resolution: ABS survey report reviewed to be satisfactory to CG.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 19 July 2023
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons on board under normal and emergency conditions. Vessel reported inoperable starboard engine. Provide transit plan, complete causal analysis and submit technical report attesting to engine repair and full operational test, following transit from current location to Belle Chasse Anchorage. Vessel is authorized to transit only with suitable tug assistance. 46 CFR 143.205(a)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 20 July 2023
Resolution: Recieved tech report attesting to proper repairs and engine function.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 9 December 2022
Resolved
The master must ensure that all lifesaving equipment is properly maintained and ready for use at all times. Vessel could not provide record of servicing for life raft hydrostatic releases. Starboard side life ring was rotting internally. 46 CFR 141.230
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 December 2022
Resolved 6 January 2023
Resolution: Donovan Marine attended on 1/1/2023 inspected and tested Liferaft secondary releases.
Fire Fighting › Emergency Fire Pumps › Pressure
Issued 19 December 2017
Resolved
Emergency Fire Pump was inoperable at time of inspection. SOLAS ('14) V/18.8
Action required: 60 - Rectify deficiencies prior to movement
Resolved 20 December 2017
Resolution: RCVD suffiecient evidence from Owner/tech that emergency fire pump was operational.
Personnel › Training › Safety Orientation
Issued 7 May 2014
Resolved
Provide a SOLAS fire fighting training manual. SOLAS09 II-2/15.2.3
Due 14 May 2014
Resolved 17 May 2014
Resolution: Manual provided. Deficiency cleared.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 7 May 2014
Resolved
Provide the CG approval letter for the fire control plan. 46 CFR 91.55-5(d)
Action required: 705 - Other - as specified
Due 2 November 2015
Resolved 23 September 2015
Resolution: Fire and Safety plan was submitted and reviewed and found to be in compliance with regualtions. An approval letter was signed and sent to the vessel rep, along with a stamped copy of the plan.
Documentation › Safety/Response Plans/Programs › General Arrangement Plans
Issued 1 May 2014
Resolved
Modify the life savings plan to include 22 immersion suits. SOLAS III/32.3.3
Extended requirement date to facilitate the logistical needs of the operator.
Due 7 July 2014
Resolved 17 May 2014
Resolution: Lifesaving plan amended by hand to reflect correct numbers and locations of immersion suits. Printed copies of new revision en route. Deficiency cleared.
Fire Fighting › Means of Escape › Blocked
Issued 1 May 2014
Resolved
Remove all exterior fasteners on the exterior of the vessel's emergency exits.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 May 2014
Resolution: Completed the above details.
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 1 July 2011
Resolved
Obtain CG approval of a FMEA, DVTP, and PSTP for the vessel's propulsion and control systems as set forth in 46CFR Parts 61 and 62.
Action required: 705 - Other - as specified
Due 14 November 2011
Resolved 3 November 2011
Resolution: Recieved MSC approval via ltr E2-1103123 dated Oct 28, 2011.
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 1 July 2011
Resolved
Make vessel available to demonstrate an approved DVTP and PSTP.
Action required: 705 - Other - as specified
Due 14 November 2011
Resolved 9 November 2011
Resolution: Test proceedures approved and verified.