MAURY USCG vessel records Sign in
← All vessels

LEGACY

LEGACY is a 2011 towing vessel. The Coast Guard has recorded 44 inspections since 2011, most recently in May 2026, along with 10 deficiencies, 1 operational control and 5 casualty investigations between 2012 and 2021.

Records from 2011 to 2026. Most recent: inspection, 22 May 2026.

Built
2011
Last inspected
22 May 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9583249 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WDF7311
967865
Flag
UNITED STATES
338504000
Maury page id
psix-967865

Inspections, by type

…with no type recorded8
Years with a record 16 calendar years (2011–2026)
The 44 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Towing Vessel class in Maury's sources begin in 1980.

Documentation record

Registered dimensions (L × B × D)142.1 ft × 60.0 ft × 30.0 ft
Registered tonnagegross 1,567 / net 1,066
ITC dimensions (L × B × D)142.1 ft × 60.0 ft × 30.0 ft
ITC tonnagegross 2,164 / net 649
BuilderDAKOTA CREEK INDUSTRIES · ANACORTES, WA, UNITED STATES · built 2011
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portSAN FRANCISCO, CA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 2 October 2025 · expires 31 October 2026
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it1567 - Regulatory (Subpart C or D), Gross Ton
2164 - Convention (Subpart B), Gross Ton
1066 - Regulatory (Subpart C or D), Net Ton
649 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDF7311MMSI 338504000 · active · compulsorily equipped · granted 5 January 2021, expires 26 March 2031
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 9

Inspection history · 44

22 May 2026 Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8378361
25 September 2025 ACP COI Oversight · Re-Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8241441
10 April 2025 ISM SMC Audit · TPO Audit
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8111179
13 December 2024 Annual Inspection · ACP Annual Oversight
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8046220
22 October 2024 Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8029801
4 September 2024 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7995789
27 November 2023 ACP Periodic Oversight · Periodic Inspection · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7830097
19 July 2023 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7746949
6 May 2023 Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7682148
28 November 2022 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7600634
16 December 2021 ACP Annual Oversight · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7369396
16 February 2021 Administrative Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7141346
16 February 2021 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7142342
28 December 2020 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7117441
6 October 2020 Re-Inspection · MTSA/ISPS Verification · ACP COI Oversight
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7069597
20 March 2020 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6929697
6 February 2020 Annual Inspection · ACP Annual Oversight
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6897263
20 February 2019 ACP Annual Oversight · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6629312
23 August 2018 MTSA/ISPS Verification · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6519962
19 December 2017 Annual Inspection · ACP Annual Oversight
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6324013
17 July 2017 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6213132
6 December 2016 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6050592
20 November 2015 COI Inspection · Drydock Exam · Internal Structural Exam · ACP Handover Survey
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5760223
2 September 2015 Administrative Inspection · Annual Inspection · MTSA/ISPS Verification · Ballast Water Examination · MARPOL Annex V Examination · MARPOL Annex I Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5231179
27 August 2015 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5728053
31 March 2015 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5093798
11 September 2014 MTSA Verification
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4981495
27 June 2014 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4905668
14 May 2014 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4858895
14 May 2014 Examination of Repairs · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4862191
14 May 2014 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4863287
5 May 2014 Internal Structural Exam · Drydock Exam · MARPOL Annex VI Survey · Deficiency Check · MARPOL Annex I Examination · Administrative Inspection · Annual Inspection · Welding Related Inspections Qualification Testing · MTSA/ISPS Verification · Hull Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4847911
7 March 2014 Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 4813180
17 September 2013 COI Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 4730795
30 July 2012 DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4396487
13 July 2012 Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4377314
26 June 2012 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4357387
6 January 2012 Damage Survey
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4222156
9 November 2011 Deficiency Check · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4186127
3 November 2011 Deficiency Check · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4181588
28 September 2011 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4156661
11 August 2011 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4112189
15 July 2011 In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4082800
1 July 2011 MTSA/ISPS Verification · Initial Certification · MARPOL Annex IV Survey · MARPOL Annex I Examination · MARPOL Annex V Examination · Initial Construction-Excluding Oversight
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4060853

Deficiency record · 10

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 4 September 2024 Resolved
The machinery, boilers and other pressure vessels, associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended. Vessel reported a loss of propulsion of the starboard main engine. Provide class report attesting to satisfactory repairs and operational testing of starboard main engine to the satisfaction of class and CG. - 74 SOLAS (20) II-1/26.1
Action required: 60 - Rectify deficiencies prior to movement
Due 5 September 2024
Resolved 5 September 2024
Resolution: ABS survey report reviewed to be satisfactory to CG.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 19 July 2023 Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons on board under normal and emergency conditions. Vessel reported inoperable starboard engine. Provide transit plan, complete causal analysis and submit technical report attesting to engine repair and full operational test, following transit from current location to Belle Chasse Anchorage. Vessel is authorized to transit only with suitable tug assistance. 46 CFR 143.205(a)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 20 July 2023
Resolution: Recieved tech report attesting to proper repairs and engine function.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 9 December 2022 Resolved
The master must ensure that all lifesaving equipment is properly maintained and ready for use at all times. Vessel could not provide record of servicing for life raft hydrostatic releases. Starboard side life ring was rotting internally. 46 CFR 141.230
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 December 2022
Resolved 6 January 2023
Resolution: Donovan Marine attended on 1/1/2023 inspected and tested Liferaft secondary releases.
Fire Fighting › Emergency Fire Pumps › Pressure
Issued 19 December 2017 Resolved
Emergency Fire Pump was inoperable at time of inspection. SOLAS ('14) V/18.8
Action required: 60 - Rectify deficiencies prior to movement
Resolved 20 December 2017
Resolution: RCVD suffiecient evidence from Owner/tech that emergency fire pump was operational.
Personnel › Training › Safety Orientation
Issued 7 May 2014 Resolved
Provide a SOLAS fire fighting training manual. SOLAS09 II-2/15.2.3
Due 14 May 2014
Resolved 17 May 2014
Resolution: Manual provided. Deficiency cleared.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 7 May 2014 Resolved
Provide the CG approval letter for the fire control plan. 46 CFR 91.55-5(d)
Action required: 705 - Other - as specified
Due 2 November 2015
Resolved 23 September 2015
Resolution: Fire and Safety plan was submitted and reviewed and found to be in compliance with regualtions. An approval letter was signed and sent to the vessel rep, along with a stamped copy of the plan.
Documentation › Safety/Response Plans/Programs › General Arrangement Plans
Issued 1 May 2014 Resolved
Modify the life savings plan to include 22 immersion suits. SOLAS III/32.3.3 Extended requirement date to facilitate the logistical needs of the operator.
Due 7 July 2014
Resolved 17 May 2014
Resolution: Lifesaving plan amended by hand to reflect correct numbers and locations of immersion suits. Printed copies of new revision en route. Deficiency cleared.
Fire Fighting › Means of Escape › Blocked
Issued 1 May 2014 Resolved
Remove all exterior fasteners on the exterior of the vessel's emergency exits.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 May 2014
Resolution: Completed the above details.
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 1 July 2011 Resolved
Obtain CG approval of a FMEA, DVTP, and PSTP for the vessel's propulsion and control systems as set forth in 46CFR Parts 61 and 62.
Action required: 705 - Other - as specified
Due 14 November 2011
Resolved 3 November 2011
Resolution: Recieved MSC approval via ltr E2-1103123 dated Oct 28, 2011.
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 1 July 2011 Resolved
Make vessel available to demonstrate an approved DVTP and PSTP.
Action required: 705 - Other - as specified
Due 14 November 2011
Resolved 9 November 2011
Resolution: Test proceedures approved and verified.

Casualty record · 5

26 June 2012Routine · role: Involved in a Marine Casualty · activity 4357387
14 May 2014Routine · role: Involved in a Marine Casualty · activity 4863287
17 July 2017Routine · role: Involved in a Marine Casualty · activity 6213132
28 December 2020Routine · role: Involved in a Marine Investigation (non-casualty) · activity 7117441
16 February 2021Routine · role: Involved in a Marine Casualty · activity 7142342
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.