Records from 2009 to 2025. Most recent: inspection, 3 December 2025.
Documentation record
Registered dimensions (L × B × D)72.5 ft × 31.0 ft × 9.8 ft
Registered tonnagegross 147 / net 118
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderC & C BOATWORKS LLC · BELLE CHASSE, LA, UNITED STATES · built 2008
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 14 August 2026 · expires 31 August 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it147 - Simplified, Gross Ton
118 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 18
3 December 2025
Type not recorded
No type recorded · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 8292215
21 July 2025
COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 8190721
29 March 2025
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 8102697
24 April 2024
Damage Survey
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7900510
7 December 2022
Examination of Repairs · Damage Survey
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 7605904
7 December 2022
Type not recorded
No type recorded · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 7610983
9 October 2022
Administrative Inspection
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7576534
26 May 2022
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7459595
22 June 2020
Initial Certification · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6992348
31 January 2020
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6907595
21 March 2019
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6661269
4 April 2018
Damage Survey
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6386131
20 July 2017
Industry Initiated Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6211811
7 December 2016
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6053902
19 November 2016
Type not recorded
No type recorded · Station New Orleans · USCG Heartland District (CGD-H) · Activity 6044388
8 April 2013
Type not recorded
No type recorded · Station New Orleans · USCG Heartland District (CGD-H) · Activity 4565427
23 April 2010
Industry Initiated Exam · MTSA Verification · DAPI Audit
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3725199
2 October 2009
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3627021
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 24 July 2025
Resolved
All bilges and void spaces must be kept free from accumulation of combustible and flammable materials and liquids insofar as practical. Also, a vessel must be in satisfactory service insofar as structural adequacy is concerned and the structure of the vessel is not questioned by the [name withheld] accumulation was discovered in the forward hold and a potential crack in the starboard fuel tank was identified. Make permanent repairs to prevent fuel from leaking into the forward hold bilge.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 25 July 2025
Resolution: See attached report. Leak repaired.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 24 April 2024
Resolved
An existing vessel may be deemed by the OCMI, or TPO, to be in compliance with this subpart provided that: The vessel has been both in satisfactory service insofar as structural adequacy is concerned and does not cause the structure of the vessel to be questioned by either the OCMI, or TPO engaged to perform an audit or survey. Vessel reported being struck by power line while transiting in vicinity of MM 2.5. After electrical hazard cleared, vessel to conduct damage survey to the satisfaction of attending Marine Inspector following transit to fleeting area in proximity of MM 7.
Condition: Damaged By Earlier Event
Action required: 60 - Rectify deficiencies prior to movement
Due 24 April 2024
Resolved 24 April 2024
Resolution: Conducted damage survey and found no notable damage.
2 October 2009Routine · role: Involved in a Marine Casualty · activity 3627021
21 March 2019Routine · role: Involved in a Marine Casualty · activity 6661269
31 January 2020Routine · role: Involved in a Marine Casualty · activity 6907595
7 December 2022Routine · role: Involved in a Marine Casualty · activity 7610983
29 March 2025Routine · role: Involved in a Marine Casualty · activity 8102697
3 December 2025Routine · role: Involved in a Marine Casualty · activity 8292215
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source:
IIR, through 2026.