Records from 1998 to 2025. Most recent: inspection, 27 August 2025.
Documentation record
Registered dimensions (L × B × D)60.3 ft × 26.0 ft × 8.0 ft
Registered tonnagegross 144 / net 97
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
Builderbuilder not recorded · GREENVILLE · built 1969
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portFRIARS POINT, MS
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 4 November 2025 · expires 30 November 2026
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it144 - Regulatory (Subpart C or D), Gross Ton
97 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 18
27 August 2025
TPO Audit
Administrative · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 8230963
1 August 2025
COI Inspection
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 8197463
24 February 2025
Administrative Inspection
Administrative · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 8083859
24 August 2022
Type not recorded
No type recorded · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 7542562
3 June 2020
Initial Certification
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 6973852
26 May 2020
Administrative Inspection
Administrative · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 6960644
25 April 2020
Type not recorded
No type recorded · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 6944689
8 October 2019
TPO Audit
Administrative · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 6886873
10 August 2018
Type not recorded
No type recorded · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 6510575
28 September 2014
Type not recorded
No type recorded · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 5001711
21 February 2012
Deficiency Check · Industry Initiated Exam
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 4248207
27 January 2009
Administration
Administrative · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 3411818
5 September 2007
Deficiency Check
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 3049537
6 February 2005
Type not recorded
No type recorded · Marine Safety Detachment Greenville · USCG Heartland District (CGD-H) · Activity 2300858
29 February 2004
Type not recorded
No type recorded · Marine Safety Detachment Greenville · USCG Heartland District (CGD-H) · Activity 2021907
8 September 2003
Type not recorded
No type recorded · Marine Safety Detachment Greenville · USCG Heartland District (CGD-H) · Activity 1906840
22 August 2001
Type not recorded
No type recorded · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 214335
14 September 1998
Type not recorded
No type recorded · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 420506
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 1 August 2025
Resolved
All bilges and void spaces are kept free from accumulation of combustible and flammable materials and liquids insofar as practicable. MI observed an excess amount of oily water in the bilge.
46 CFR 142.220(a)
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 1 August 2025
Resolved 12 August 2025
Resolution: Pumped out accumlilated water.
08 - Alarms › N/A - No Subsystem › General alarm
Issued 1 August 2025
Resolved
Each towing vessel must be fitted with a general alarm that: Is activated at each operating station and can notify persons onboard in the event of an emergency. MI observed the emergency alarm inoperable during a loss of power event.
46 CFR 143.235(b)(1)
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 1 August 2025
Resolved 12 August 2025
Resolution: Alarm wired to battery back-up
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 1 August 2025
Resolved
All seals and gaskets must be properly maintained to prevent leaks of flammable or combustible liquid into the machinery space. MI observed a hydraulic oil leak on the steering pump service tank.
46 CFR 143.220(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 August 2025
Resolved 12 August 2025
Resolution: See TPO report in docs.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 1 August 2025
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. MI observed an excessive raw water leak on the port main engine.
46 CFR 143.205(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 August 2025
Resolved 12 August 2025
Resolution: See TPO report in docs.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 1 August 2025
Resolved
The following systems must be equipped with gauges at the machinery location: main engine RPM. MI observed the starboard main engine RPM gage inoperable.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 August 2025
Resolved 12 August 2025
Resolution: See TPO report in docs.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 1 August 2025
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. MI observed a persistent exhaust leak from the port main engine turbo seal.
46 CFR 143.205(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 August 2025
Resolved 12 August 2025
Resolution: See TPO report in docs.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 1 August 2025
Resolved
Piping and machinery components that exceed 220 °C (428 °F), including fittings, flanges, valves, exhaust manifolds, and turbochargers, must be insulated. MI observed insufficient exhaust lagging on the starboard generator.
46 CFR 143.220(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 August 2025
Resolved 12 August 2025
Resolution: See TPO report in docs.
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 1 August 2025
Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards. MI observed all spare breakers left in the "on" position.
46 CFR 143.400(a)
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Due 1 August 2025
Resolved 1 August 2025
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 26 May 2020
Resolved
All owners & operators of an existing towing vessel must have a valid COI prior to the specified phase-in period. This vessel is on of the 25% of the vessels that has not obtained a valid COI. the vessel shall be made available for a Coast Guard COI inspection within 90 days*. If an inspection is not completed prior to this date, the action for this deficiency shall be changes to a CODE 60(Rectify deficiencies prior to movement) and the vessel may no longer be permitted to operate.
*Your vessel is utilizing the TPO/TSMS compliance option, therefore your vessel shall meet all the COI requirements of your TPO and submit all required documentation to our office in Memphis, TN.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 August 2020
Resolved 21 July 2020
Resolution: Company provided all documentation to confirm compliance with SUB M TSMS Option. COI for vessel routed for signature.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 14 September 1998
Resolved
LIGHTS ON RING BOUYS NOT WORKING PROPERLY._x001C_
Condition: Unknown
Due 14 October 1998
Resolved 5 September 2007
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 14 September 1998
Resolved
NAVIGATION SIDE LIGHTS SCREENS WERE PAINTED GLOSS BLACK INSTEAD OF MATTE BLACK._x001C_
Condition: Unknown
Due 14 October 1998
Resolved 5 September 2007
Lifesaving › Lifeboat Equipment › Instructions (engine start/operation)
Issued 14 September 1998
Resolved
VESSEL HAD NO GUARDS AROUND ALL MOVING MACHINERY IN ENGINE ROOM.
Condition: Unknown
Due 14 October 1998
Resolved 14 September 1998
Navigation › Piloting/Steering › Local Notices to Mariners
Issued 14 September 1998
Resolved
VESSEL HAD NO COAST GUARD LOCAL NOTICE TO MARINERS ON BOARD._x001C_ _x001C_
Condition: Unknown
Due 14 October 1998
Resolved 5 September 2007
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 14 September 1998
Resolved
VESSEL'S FIRE EXTINGUISHERS WERE NOT PROPERLY MOUNTED._x001C_
Condition: Unknown
Due 14 October 1998
Resolved 5 September 2007