Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Towing Vessel class in Maury's sources begin in 1980.

Inspection record

Last inspected 9 May 2026
…with no type recorded28
Operational controls None recorded without a removal date
Years with a record 23 calendar years (1990–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

8644498
WDB2352
152914
Flag
UNITED STATES
Maury page id
psix-152914

Documentation record

Registered dimensions (L × B × D)65.6 ft × 24.0 ft × 9.4 ft
Registered tonnagegross 147 / net 100
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderRAYCO SHIPBUILDERS & REPAIRS INC · BOURG, LA, UNITED STATES · built 1977
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portNEW ORLEANS, LA
Endorsements, as the file codes themcw_un
DocumentationValid · issued 16 April 2026 · expires 30 April 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it147 - Regulatory (Subpart C or D), Gross Ton
100 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 50 inspections, each with its date, unit and type; 50 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; 24 other vessels inspected with it; 1 other recorded name; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 24

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

TRS 213 B Freight Barge · MISLE 1331013 · 20 January 2026 · activity 8300343MTC 650 Freight Barge · MISLE 801971 · 21 April 2024 · activity 7900835WARRIOR Freight Ship · MISLE 1188136 · 21 April 2024 · activity 7900835MISS CARTER W Towing Vessel · MISLE 1768438 · 1 March 2024 · activity 7913688ART-948 Freight Barge · MISLE 993010 · 12 October 2023 · activity 7813183CCL 409 Tank Barge · MISLE 1225384 · 12 October 2023 · activity 7813183KIRBY 29080 Tank Barge · MISLE 1219807 · 20 September 2023 · activity 7804623FORKED ISLAND Towing Vessel · MISLE 1329302 · 20 September 2023 · activity 7804623BLUE WING Towing Vessel · MISLE 1132175 · 15 March 2022 · activity 7416095ACL 01131 Freight Barge · MISLE 34696 · 9 March 2021 · activity 7155029MTC 226B Freight Barge · MISLE 372217 · 9 March 2021 · activity 7155029MTC 2229 Freight Barge · MISLE 672406 · 9 March 2021 · activity 7155029CCL 16 Tank Barge · MISLE 728378 · 9 March 2021 · activity 7155029M/G 151 * Freight Barge · MISLE 114175 · 14 August 2019 · activity 6783497M/G 165 * Freight Barge · MISLE 114189 · 14 August 2019 · activity 6783497M/G 235 Freight Barge · MISLE 114219 · 14 August 2019 · activity 6783497GBW 97 Freight Barge · MISLE 457170 · 14 August 2019 · activity 6783497M/G 201 Freight Ship · MISLE 831978 · 14 August 2019 · activity 6783497M/G 244 Freight Ship · MISLE 866911 · 14 August 2019 · activity 6783497TTT 330 Tank Barge · MISLE 470204 · 15 January 2007 · activity 2857332TTT 320 Tank Barge · MISLE 470338 · 15 January 2007 · activity 2857332TTT 310 Tank Barge · MISLE 371801 · 31 October 1996 · activity 174015STC 101 Tank Barge · MISLE 51996 · 30 January 1995 · activity 14720STC 101 Tank Barge · MISLE 51996 · 28 December 1993 · activity 167673TTT 310 Tank Barge · MISLE 371801 · 14 March 1993 · activity 156833TTT 310 Tank Barge · MISLE 371801 · 30 October 1992 · activity 53478CHEM 430 Tank Barge · MISLE 50159 · 24 April 1992 · activity 89424

Inspection history · 50

9 May 2026 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 8373725
30 January 2026 Deficiency Check
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 8304170
25 January 2026 Damage Survey
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 8301444
20 January 2026 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 8300343
10 November 2025 Annual Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 8266675
19 August 2024 Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 7984944
21 April 2024 Administrative Inspection · Damage Survey
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7899172
21 April 2024 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7900835
1 March 2024 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7913688
12 October 2023 Internal Structural Exam · Administrative Inspection · Damage Survey · Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7807715
12 October 2023 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7813183
6 October 2023 Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 7804633
26 September 2023 Administrative Inspection · Permit to Proceed
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7798746
21 September 2023 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7795694
21 September 2023 Permit to Proceed · Damage Survey · Administrative Inspection · Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7797318
20 September 2023 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7804623
17 September 2023 Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7792916
14 June 2022 Annual Inspection · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7477008
15 March 2022 Type not recorded
No type recorded · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 7416095
13 April 2021 Annual Survey
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7227157
9 March 2021 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7155029
24 February 2021 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7145579
14 August 2019 Damage Survey · Deficiency Check
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 6783385
14 August 2019 Type not recorded
No type recorded · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 6783497
9 July 2019 Initial Certification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6734046
7 May 2016 Damage Survey
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5871315
20 March 2014 MTSA Verification · Industry Initiated Exam · MARPOL
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 4819787
14 February 2013 Type not recorded
No type recorded · Station New Orleans · USCG Heartland District (CGD-H) · Activity 4533603
25 August 2010 MTSA Verification · MARPOL · Industry Initiated Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3834108
30 October 2009 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3678010
7 May 2009 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3469591
5 May 2009 Administration
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3469331
15 January 2007 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2857332
20 April 2006 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2629494
13 December 2004 Deficiency Check · MTSA Verification
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2258433
9 November 2004 MTSA Verification
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2238072
26 March 2003 Type not recorded
No type recorded · Station Dauphin Island · USCG Heartland District (CGD-H) · Activity 1763602
6 March 2003 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1757003
24 January 2001 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 65384
3 October 1997 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 412449
31 October 1996 Type not recorded
No type recorded · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 174015
30 January 1995 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 14720
28 December 1993 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 167673
22 September 1993 Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 31717
22 September 1993 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 37327
14 March 1993 Type not recorded
No type recorded · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 156833
30 October 1992 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 53478
27 October 1992 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 48767
24 April 1992 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 89424
25 October 1990 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 529438

Deficiency record · 50

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 25 January 2026 Resolved
Propulsion machinery, including shafting, must be maintained to ensure proper operation. The vessel experienced a failure of a flange in the port main propulsion shaft assembly that rendered the port main engine inoperable. Vessel must effect repairs to the satisfaction of a Coast Guard Marine Inspector and conduct satisfactory tests to ensure proper operation of the port shaft assembly. **To facilitate repairs, the vessel has been authorized to transit from the Marine Safety Unit Lake Charles area of responsibility to Verret Shipyard near Baton Rouge, LA. Repairs must be conducted to the satisfaction of a Coast Guard marine inspector prior to returning the vessel to service.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 25 January 2026
Resolved 30 January 2026
Resolution: O/O provided statements that the proper operational tests were completed and that no damage was found to the properller or shaft.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 10 November 2025 Resolved
Machinery and electrical systems must be designed and maintained to provide safe operation of the towing vessel and electric systems must be designed to minimize system failures. The forward bilge alarm was wired using a re-purposed extension cord. Replace wiring with marine type shipboard wiring.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 December 2025
Resolved 25 November 2025
Resolution: Wiring replaced with proper
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 10 November 2025 Resolved
Machinery and electrical systems must be designed and maintained to provide safe operation of the towing vessel. The intake piping for starboard main engine was improperly installed/mounted using lagging wire and duct tape. Repair intake piping.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 December 2025
Resolved 25 November 2025
Resolution: Fixed intake piping
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 10 November 2025 Resolved
Machinery and electrical systems must be designed and maintained to provide safe operation of the towing vessel. Several fuel hoses on both generators were dry-rotted and need replaced. Also, install compression-type fittings and double hose clamps (where applicable) at all hose joints.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 December 2025
Resolved 25 November 2025
Resolution: Repaired fuel hoses
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 6 September 2024 Resolved
A towing vessel with overnight accommodations and alternating watches (shift work), when pulling, pushing or hauling alongside one or more barges, must have a system to detect when its master or mate (pilot) becomes incapacitated. Vessel has an inoperable system installed. Make repairs to system.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 September 2024
Resolved 13 September 2024
Resolution: Objective Evidence provided of repair.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 6 September 2024 Resolved
Pressure vessels over 5 cubic feet in volume and over 15 pounds per square inch maximum allowable working pressure (MAWP) must be equipped with an indicating pressure gauge (in a readily visible location) and with one or more spring-loaded relief valves. The total relieving capacity of such relief valves must prevent pressure from exceeding the MAWP, as established by the manufacturer, by more than 10 percent. Port PV did not have a relief valve installed. Install Pressure relief valve.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 September 2024
Resolved 13 September 2024
Resolution: Objective Evidence provided of relief valve installation.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 6 September 2024 Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards. Switchboard on forward engine room bulkhead was missing knockouts. Repair/replace.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 September 2024
Resolved 13 September 2024
Resolution: Objective Evidence provded of covers installed.
08 - Alarms › N/A - No Subsystem › General alarm
Issued 27 August 2024 Resolved
Each towing vessel must be fitted with a general alarm that is activated at each operating station and can notify persons on board in the event of an emergency. General alarm activation points were not functioning at the time of inspection. Repair general alarm call points.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 27 August 2024
Resolved 6 September 2024
Resolution: General Alarm replaced and tested satisfactory.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 August 2024 Resolved
Main engines and auxiliary generators must have low lubricating oil pressure and high jacket water temperature gauges. Subject alarms were not functioning properly at the time of inspection. Repair subject alarms.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 27 August 2024
Resolved 6 September 2024
Resolution: Alarms tested and witnessed satisfactory.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 27 August 2024 Resolved
All lifesaving equipment must be tested and maintained in accordance with the minimum requirements of 199.190 of this chapter. The hydrostatic release unit for the EPIRB is expired. Replaced hydrostatic release unit.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 27 August 2024
Resolved 6 September 2024
Resolution: Replaced NIK.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 27 August 2024 Resolved
An exposed hazard such as gears and rotating machinery, must be protected by a cover, guard or rail. Replace missing framing that supports guard over the stbd main engine shaft.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 27 August 2024
Resolved 6 September 2024
Resolution: Framing repaired/replaced.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 19 August 2024 Resolved
Regardless of the option chosen to obtain a COI, upon obtaining a COI each towing vessel must then undergo a drydock and internal structural examination at the following intervals: A vessel that is exposed to salt water not more than 6 months in any 12-month period since the last examination or initial certification must undergo a drydock and internal structural examination at least once every 5 years. Complete the attached worklist items, a satisfactory credit drydock and Internal Structural Exam, prior to operations.
Action required: 705 - Other - as specified
Due 20 August 2024
Resolved 6 September 2024
Resolution: Drydock and ISE completed and credited on this date.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 21 April 2024 Resolved
A vessel must be operated in accordance with applicable laws and regulations, and in such a manner as to afford protection against hazards to life, property, and the environment. Vessel reported a collision with unknown extent of damage. Conduct a damage survey to determine extent of damage to the satisfaction of the Coast Guard. Prepare a transit plan to location of repairs and conduct any necessary repairs to the satisfaction of the attending Marine Inspector.
Action required: 60 - Rectify deficiencies prior to movement
Due 1 May 2024
Resolved 22 April 2024
Resolution: Vessel inspected by USCG Duty Team. All sat.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 12 October 2023 Resolved
46 CFR 143.245 (a) Essential systems or equipment must be regularly tested and examined. Tests and examinations must verify that the system or equipment functions as designed. If a component is found unsatisfactory, it must be repaired or replaced. During casualty response, marine inspectors discovered steering gear heavily corroded and structurally compromised. Port and starboard main rudder assemblies appeared inadequately supported and lower to the deck with the starboard actuator head scraping the deck during operational tests. Main rudder follow-up linkage to the bridge was found broken due to corrosion. Flanking rudder follow-up linkage assembly bearing was found corroded and unsecured. Several grease hoses were disconnected without existing alternative procedures for similar maintenance. Vessel must prove satisfactory condition and operability of the steering system including all components and appendages above and below the waterline.
Action required: 30 - Ship detained
Resolved 16 October 2023
Resolution: Linkages/hoses repaired/replaced as necessary. A satisfactory operational test of the steering was observed by attending MIs.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 12 October 2023 Resolved
46 CFR 137.300(b) The cognizant OCMI may require additional examinations of the vessel whenever he or she discovers or suspects damage or deterioration to hull plating or structural members that may affect the seaworthiness or fitness for the route or service of a vessel. These examinations may include a drydock examination, including: (1) An internal structural examination of any affected space of a vessel, including its fuel tanks; (2) A removal of the vessel from service to assess the extent of the damage and to affect permanent repairs; or (3) An adjustment of the drydock examination intervals to monitor the vessel's structural condition. During post-collision repairs, an approximately 5-foot section of major transverse structural member in the aft engine room overhead (below the second deck) was cut and removed without replacement along with corresponding vertical structural members to the bulkhead. Repairs do not feature full-penetration welds or radiused corners. Exhaust stack damage from previous collision has not been repaired. Longitudinal bulkheads within both aft rudder post voids were found buckled and separated from deck plating. Prior to any structural repairs, the vessel shall schedule an internal structural exam with Sector Houston Galveston Domestic Inspections to determine the extent of damage and required repairs.
Action required: 30 - Ship detained
Resolved 16 October 2023
Resolution: Items determined to require immediate repair were repaired and had satisfactory NDT performed by attending MIs.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 12 October 2023 Resolved
46 CFR 142.220 (a) All bilges and void spaces are kept free from accumulation of combustible and flammable materials and liquids insofar as practicable. Marine inspector observed excessive oil and oily water in the engine room bilges. Vessel shall clean all bilges of combustible and flammable liquids.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 16 October 2023
03 - Water/Weathertight Conditions › N/A - No Subsystem › Cargo ports and other similar openings
Issued 12 October 2023 Resolved
46 CFR 143.270 Piping and tanks exposed to the outside of the hull must be made of metal and maintained in a leak free condition. Slop tank located on the aft main deck is unable to be closed due to a damaged hatch. Existing slop tank repair of 1-foot by 1-foot at the main deck has no radii or relief cuts at the corners. Vessel shall repair the tank to its original condition and conduct non-destructive testing prior to use.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 16 October 2023
Resolution: Verfied repairs complete.
09 - Working and Living Conditions › 091 - Living Conditions › Access/structure
Issued 12 October 2023 Resolved
46 CFR 140.510 (a)(2) The owner or managing operator must implement procedures to identify and mitigate health and safety hazards, including but not limited to: Slips, trips, and falls. Marine inspectors identified various structural conditions leading to operational safety hazards including: Improper and incomplete repairs made to the aft second deck following recent collision, deck grating over the steering gear assembly inadequately supported and heavily corroded, and buckled stair supports on the aft main deck. Repair to Coast Guard satisfaction prior to reissuance of the COI.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 16 October 2023
Resolution: Verfied required repairs complete.
09 - Working and Living Conditions › 091 - Living Conditions › Dirty, parasites
Issued 12 October 2023 Resolved
The owner or managing operator must implement procedures to identify and mitigate health and safety hazards, including but not limited to: Blood-borne pathogens and other biological hazards. Marine inspectors witnessed a live rat caught in the steering gear assembly. Provide objective evidence from a licensed party that the vessel is free of pests.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 October 2023
Resolution: Inspectors conducted detailed inspection of the galley and provision areas and noted no signs of biological hazards.
09 - Working and Living Conditions › 092 - Working Conditions › Winches & capstans
Issued 12 October 2023 Resolved
46 CFR 143.460 Each owner or managing operator must develop procedures to routinely examine, maintain, and replace capstans, winches, and other machinery used to connect the towing vessel to the tow. Starboard winch electrical brake assembly casing is heavily corroded exposing electrical components and hazard to personnel. Vessel shall renew winch electrical brake assembly casing prior to operation and develop a maintenance procedure and periodic examination schedule to ensure its mooring equipment is in suitable condition.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 October 2023
Resolution: Verfied cover replaced.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 12 October 2023 Resolved
46 CFR 143.400 Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards. Port engine lube oil pressure switch connections are exposed and spliced open; one cable is disconnected from its sensor. Vessel shall conduct an operational test of all engine alarms in the presence of a marine inspector.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 October 2023
Resolution: Verfied proper operation of lube oil alarm.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 12 October 2023 Resolved
46 CFR 140.910 (b) & (c) A towing vessel subject must maintain a TVR. The TVR must include a chronological record of events as required by this subchapter. Vessel port clutch actuator failed the previous day, 11OCT2023. Electronic logbook and/or "Helms" system used for record-keeping did not have any chronological entry reflecting the partial loss of propulsion.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 October 2023
Resolution: Inspectors reviewed "helm" system for previous voyage plans, maintenance reports, and daily logs.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 12 October 2023 Resolved
46CFR144.330 An OCMI may require a review to ensure that a towing vessel is maintained and operated so that the watertight integrity and stability of the vessel are not compromised. Approximately 3” of water was found in flanking rudder voids. Pump out water and determine cause to the satisfaction of OCMI and make vessel available for an Internal Structural Exam.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 October 2023
Resolution: Vessel pumped out standing water in voids and had the spaces certified safe by a marine chemist. Inspectors entered and examined each void and did not observe any signs of water intrusion.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 12 October 2023 Resolved
46 CFR 143.245 (a) Essential systems or equipment must be regularly tested and examined. Tests and examinations must verify that the system or equipment functions as designed. If a component is found unsatisfactory, it must be repaired or replaced. Vessel’s port clutch actuator was found replaced and operable following previous day failure.
Action required: 10 - Deficiency Rectified
Resolved 16 October 2023
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 6 October 2023 Resolved
Each towing vessel that operates solely on Rivers need not carry a survival craft of it carries a 406 MHz Cat 1 EPIRB. EPIRB was not onboard. Vessel is restricted to not more than one (1) mile from shore until EPIRB is replaced.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 November 2023
Resolved 15 October 2023
Resolution: EPIRB was placed on board vessel with proper registration.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 6 October 2023 Resolved
Towing vessels of more than 65 feet in length must carry one 40-B portable fire extinguisher fitted in the engine room for each 1,000 brake horsepower of the main engines or fraction thereof. Of the 02 required in the engine room by this part, 01 CO2 type extinguisher was due for a hydrostatic test. Replace the CO2 extinguisher with a 40-B portable fire extinguisher in the engine room.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 6 October 2023
Resolved 6 October 2023
Resolution: Vessel had a spare extinguisher in good working order and swappped it with the deficient extinguisher.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 6 October 2023 Resolved
On towing vessels greater than 26ft at leas two life buoys must be fitted with a floating electric water light. Port side floating water light was inoperable.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 6 October 2023
Resolved 6 October 2023
Resolution: Vessel had a spare floating water light in good working order and swapped it with the deficient floating water light.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Cargo ports and other similar openings
Issued 6 October 2023 Resolved
Piping and tanks exposed to the outside of the hull must be made of metal and maintained in a leak free condition. Slop tank located on the aft main deck will not close and seal properly. Repair coaming and cover.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 November 2023
Resolved 15 October 2023
Resolution: Slop tank hatch cover was repaired and closes properly.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 6 October 2023 Resolved
Electrical systems and equipment must function properly and minimize system failures and fire shock hazards. Wire along over head in forward stores just forward of the ladder is coiled up with exposed wires at the end.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 October 2023
Resolved 9 October 2023
Resolution: Exposed wiring was removed.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 6 October 2023 Resolved
Each towing vessel must have a reliable means to provide notification of high bilge levels. High bilge level alarm was missing from forward hold. Install high bilge level alarm prior to completion of next drydock.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 August 2024
Resolved 13 September 2024
Resolution: Witnessed correction while in dry-dock.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 21 September 2023 Resolved
All bilges and void spaces are kept free from accumulation of combustible and flammable materials and liquids insofar as practicable. Fuel and lube oil was found on bilges during material inspection. 46 CFR 144.800(a) Clean all bilges from any flammable or combustible liquids.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 September 2023
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 21 September 2023 Resolved
Propulsion machinery, including main engines, reduction gears, shafting, bearings, and electrical equipment and systems, must: (1) Be maintained to ensure proper operation. Engines' exhaust pipe support brackets are not properly installed/connected. Exhaust pipe shall be properly supported. 46 CFR 13.205(c)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 September 2023
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 21 September 2023 Resolved
Essential systems or equipment must be regularly tested and examined. Tests and examinations must verify that the system or equipment functions as designed. If a component is found unsatisfactory, it must be repaired or replaced. Port steering gear rudder linkage appeared heavily corroded at its midsection thus compromising its functionality. Hydraulic linear actuator for the port rudder had several grease hoses disconnected and holding pin was able to be lifted by hand. Repair port steering gear assembly as designed by manufacturer. 46 CFR 143.245 (a)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 September 2023
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 21 September 2023 Resolved
Piping and machinery components that exceed 220 °C (428 °F), including fittings, flanges, valves, exhaust manifolds, and turbochargers, must be insulated. Port exhaust pipe was missing lagging. Add lagging to exposed parts of the exhaust piping system. 46 CFR 143.220
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 September 2023
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 21 September 2023 Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards. Battery cables were laying on deck and were not properly secured. Failure of such may result on a possible tripping and electrical hazard. Run battery cables with adequate support preventing the risk from someone tripping or disconnecting the cables by accident. 46 CFR 143.400(a)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 September 2023
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 21 September 2023 Resolved
Decks and bulkheads designed to be watertight or weathertight must be maintained in that condition. Aft engine room, exhaust stack bulkhead, and deck including vents for the engine room were damaged by collision. Crop and renew affected area by the collision and repair to its original condition. Repair must be conducted to the satisfaction of a CG Marine Inspector prior re-issuance of the COI.
Action required: 705 - Other - as specified
Resolved 6 October 2023
Resolution: Affected structure was cropped and renewed.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Bulwarks and freeing ports
Issued 21 September 2023 Resolved
Rails or equivalent protection must be installed near the periphery of all decks accessible to crew. Aft 2nd deck handrails and aft main deck bulwarks was severely damaged by the collision. Crop and renew affected area and repair to its original condition to the satisfaction of CG Marine Inspector prior re-issuance of COI. 46 CFR 144.800
Action required: 705 - Other - as specified
Resolved 6 October 2023
Resolution: Damaged hand rails and courses were replaced with new material.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 21 September 2023 Resolved
The owner or managing operator must implement procedures to identify and mitigate health and safety hazards, including but not limited to: slips, trips, and falls. Stern deck grating support brackets are heavily corroded and several welds are cracked compromising the integrity of the platform. Repair to satisfaction of CG Marine Inspector prior re-issuance of COI. 46 CFR 140.510(a)(2)
Action required: 705 - Other - as specified
Resolved 6 October 2023
Resolution: Vessel replaced support brackets with new metal and welded new ones in place.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Cargo ports and other similar openings
Issued 21 September 2023 Resolved
Piping and tanks exposed to the outside of the hull must be made of metal and maintained in a leak free condition. Slop tank located on the aft of the main deck is severely damaged. Vessel shall repair tank to its original condition prior being used. 46 CFR 143.270
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 November 2023
Resolved 27 August 2024
Resolution: Vessel owner repaired slop tank to original condition.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 21 September 2023 Resolved
The officer in charge of a navigational watch must keep the navigation assessment up-to-date to reflect changes in conditions and circumstances. This includes updates during the voyage or trip as necessary. At each change of the navigational watch, the oncoming officer in charge of the navigational watch must review the current navigation assessment for necessary changes. A navigation assessment entry must be recorded in the TVR, official log, or in accordance with the TSMS applicable to the vessel. Master of the vessel couldn't provide objective evidence of such record. Provide record of navigational assessment and logbook entries during upcoming annual inspection. 46 CFR 140.635(b)&(d)
Action required: 705 - Other - as specified
Resolved 6 October 2023
Resolution: Observed records and logs for navigational watches and assesments.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 21 September 2023 Resolved
If a dedicated storage cabinet is provided it must be secured to the vessel so that it does not move. Flammable storage locker was not secured to the bulkhead or deck. Secured flammable locker to prevent movement while underway. 46 CFR 142.225(c)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 October 2023
Resolved 6 October 2023
Resolution: Flammable storage locker was removed from the vessel.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 21 September 2023 Resolved
The following systems must be equipped with gauges at the machinery location: (1) Main engine lubricating oil pressure and main engine RPM. Port and starboard engine room gauges do not show accurate readings. Calibrate and/or renew gauges accordingly. 46 CFR 143.230(c)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 October 2023
Resolved 6 October 2023
Resolution: Gauges were calibrated and verified local guages were reading properly.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 21 September 2023 Resolved
Essential systems or equipment must be regularly tested and examined. Tests and examinations must verify that the system or equipment functions as designed. If a component is found unsatisfactory, it must be repaired or replaced. Port steering gear hydraulic linear actuator pin is missing its cotter pin thus preventing from being lifted. Tiller linkage is bent and corroded. A coat of anti-corrosion paint has been applied but condition still appears to be compromised. Repair port steering gear assembly as designed by manufacturer prior re-issuance of COI. 46 CFR 143.245 (a)
Action required: 705 - Other - as specified
Resolved 6 October 2023
Resolution: Inspected linkage and cotter pin installation. Satisfactory installation and material condition of linkage.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Documentation-ISM
Issued 21 September 2023 Resolved
A towing vessel subject must maintain a TVR. The TVR must include a chronological record of events as required by this subchapter. Electronic logbook and/or "Helms" system used for record-keeping did not have any chronological entry of the incident/casualty. Additionally, items required to be recorded as per 46 CFR 140.915 were not evident during inspection. Provide objective evidence of accurate record keeping of all entries required per 46 CFR 140.915 to include essential systems required tests listed on 46 CFR Table 143.245(b) prior re-issuance of COI. 46 CFR 140.910(b)&(c)
Action required: 705 - Other - as specified
Resolved 6 October 2023
Resolution: Observed objective evidence of required record keeping entries.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 21 September 2023 Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. Although installed in a battery tray, starting batteries for generators were not properly secured and/or supported. Battery tray and conductors were loose. Battery tray could easily be tipped which can allow for starting battery to come out and create an electrical fire hazard. Additionally, there is a freshwater overflow pipe on the starboard bulkhead which is dripping water within one foot from the starboard engine battery. This pipe appeared to be originally connected to the bilge but has now being cut. Crew temporarily put duct tape to prevent water from coming out. Light fixture on same area is shattered. Starboard bow winch motor junction box gland is broken and conductors are exposed. Light fixtures on same location (fwd) conductors are exposed to the environment and not properly fitted inside the fixture. Engine exhaust supporting brackets and flanges were missing several hardware. Repair all mentioned items to prevent any fire and/or shock hazards to the satisfaction of a Coast Guard marine inspector prior the re-issuance of the COI. 46 CFR 143.205(a)
Action required: 705 - Other - as specified
Resolved 6 October 2023
Resolution: Made round of the vessel checking the several items called out. All items were satisfactorily addressed.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 17 September 2023 Resolved
All bilges and voids are kept free from accumulation of combustible and flammable materials and liquids insofar as practable. Excessive fuel oil leakage into engine room bilge via atomizing spray from #2 generator fuel supply line.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 17 September 2023
Resolved 17 September 2023
Resolution: Pumped out bilges to facility and replaced fuel line.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 14 June 2022 Resolved
EACH TOWING VESSEL MUST HAVE A RELIABLE MEANS TO PROVIDE NOTIFICATION WHEN AN EMERGENCY CONDITION EXISTS OR AN ESSENTIAL SYSTEM DEVELOPS PROBLEMS THAT REQUIRE ATTENTION. PORT SIDE MAIN ENGINE LOW LUB OIL PREEUSRE ALARM IS INOPERABLE.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 June 2022
Resolved 16 June 2022
Resolution: Received video evidence of port main engine low oil level is operational.
Navigation
Issued 3 October 1997 Resolved
Provide on board a stern light that is visibile for 135 degrees.
Condition: Unknown
Due 3 February 1998
Resolved 3 February 1998
Lifesaving
Issued 3 October 1997 Resolved
Vessel is required to have a EPIRB due to her route off the coast of Fla.
Condition: Unknown
Due 3 February 1998
Resolved 3 February 1998
Lifesaving
Issued 3 October 1997 Resolved
Provide on board vessels a manchinery guard for #1 generator pully.
Condition: Unknown
Due 3 February 1998
Resolved 3 February 1998

Recorded names · 1

HERNDON R (2007–2009). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.