Records from 1995 to 2020. Most recent: inspection, 10 March 2020.
Inspection history · 86
10 March 2020
Administrative Inspection
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6924857
22 July 2019
Deficiency Check
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6767214
19 July 2019
Annual Inspection · MARPOL Annex I Examination · Administrative Inspection · MTSA/ISPS Verification
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6755244
19 November 2018
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6593651
19 June 2018
Examination of Repairs · MTSA Verification · Internal Structural Exam · Periodic Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6449594
16 May 2018
Damage Survey
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6416145
15 May 2018
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6445134
29 November 2017
Deficiency Check · Examination of Repairs
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6314372
21 June 2017
Annual Inspection · MARPOL Annex I Examination · MTSA Verification
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6176505
18 July 2016
Annual Inspection · MARPOL Annex I Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5940914
12 March 2016
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5831791
15 January 2016
Damage Survey
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5798342
15 January 2016
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5798492
3 December 2015
Administrative Inspection
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 5779220
19 June 2015
COI Inspection · Deficiency Check · Hull Examination · Cargo Tank Internal · MARPOL Annex I Examination · MTSA Verification
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 5155168
20 April 2015
Damage Survey · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5106948
15 April 2015
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5104308
15 April 2015
Damage Survey
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5105071
16 November 2014
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5027613
2 October 2014
Damage Survey
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4997736
28 August 2014
Deficiency Check
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 4968205
22 August 2014
MTSA Verification · Annual Inspection · MARPOL Annex I Examination
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 4955966
20 June 2014
Examination of Repairs · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4890531
4 June 2014
Permit to Proceed · Damage Survey
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 4879562
12 November 2013
Damage Survey
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 4750986
10 November 2013
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 4752543
16 September 2013
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 4716987
4 September 2012
MTSA/ISPS Verification · Annual Inspection · MARPOL Annex I Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4417048
6 September 2011
MARPOL Annex I Examination · Annual Inspection · MTSA/ISPS Verification
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 4137616
30 June 2011
Damage Survey
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4064168
27 April 2010
DAPI Audit · MARPOL Annex I Examination · Drydock Exam · COI Inspection · Hull Examination · Internal Structural Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3723076
21 February 2010
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3721489
26 May 2009
Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3486114
19 September 2008
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 3331448
21 August 2008
MARPOL Annex V Examination · Periodic Inspection · MTSA Verification · MARPOL Annex I Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3304583
27 May 2008
Examination of Repairs · Internal Structural Exam · MARPOL Annex I Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3211853
27 July 2007
Annual Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3008692
29 December 2006
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2847750
3 March 2006
Annual Inspection · Deficiency Check · MARPOL Annex I Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2595397
19 April 2005
MTSA Verification
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2337526
11 April 2005
Internal Structural Exam · Cargo Tank Internal · COI Inspection · Hull Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2330964
26 October 2004
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2228556
17 June 2004
Annual Inspection
Physical examination · MIDET WEST DETAIL · USCG Heartland District (CGD-H) · Activity 2101748
9 March 2004
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2030577
17 February 2004
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2016379
12 December 2003
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1980831
21 May 2003
Administrative Inspection
Administrative · MSFO BUCKSPORT · USCG Northeast District (CGD-NE) · Activity 1798361
1 April 2003
Internal Structural Exam
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1762295
4 September 2002
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1670710
3 September 2002
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1670380
22 August 2002
Annual Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1663500
1 August 2002
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1678287
8 June 2001
Deficiency Check
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1065546
10 May 2001
COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1408734
1 October 2000
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 133868
27 September 2000
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 460380
27 September 2000
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1054131
12 June 2000
Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1450488
12 May 2000
Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1430851
9 December 1999
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 82356
3 September 1999
Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 143888
7 July 1999
Administrative
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1092138
25 May 1999
COI Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 801691
13 December 1998
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 499136
22 October 1998
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 483030
16 September 1998
Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 675911
11 September 1998
Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 161182
11 September 1998
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 217442
21 July 1998
Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1413386
1 December 1997
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 75965
8 September 1997
Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 407659
7 September 1997
Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 452435
24 July 1997
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 783203
2 July 1997
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 777978
10 June 1997
COI Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 775233
2 June 1997
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 675912
27 May 1997
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 11890
27 May 1997
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 224677
27 May 1997
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1108697
9 August 1996
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1085444
16 January 1996
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 497764
26 September 1995
Type not recorded
No type recorded · COTP LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 675909
24 September 1995
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 461939
28 August 1995
Type not recorded
No type recorded · COTP LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 538205
24 June 1995
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 864105
24 June 1995
COI Inspection · Initial Construction-Excluding Oversight
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1377506
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 10 March 2020
Resolved
If, during an examination damage or deterioration to the hull plating, structural members, or cargo tanks is discovered, the Officer in Charge, Marine Inspection, may require the vessel to be drydocked or otherwise taken out of service to further assess damage and to effect permanent repairs. Vessel has a crack/hole in the #2 starboard cargo tank requiring permanebt reapirs. Will be cleared upon satisfactory report from TPO recieved by a qualified insoector.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 April 2020
Resolved 13 March 2020
Resolution: Plating between ballast tank and cargo tank was cropped and renewed. ABS attended shipyard and witnessed satisfactory air test of repair.
01 - Certificates & Documentation › 013 - Documents › Oil record book
Issued 19 July 2019
Resolved
Each operation described in paragraphs (d), (e) and (f) of this section shall be fully recorded without delay in the Oil Record Book so that all the entries in the book appropriate to that operation are completed. Each completed operation shall be signed by the person or persons in charge of the operations concerned and each completed page shall be signed by the master or other person having charge of the ship. Vessel is required to provide training to personnel on proper entries of the oil record book to the satisfaction of the marine inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 August 2019
Resolved 22 July 2019
Resolution: Barge rep had training with crew.
01 - Certificates & Documentation › 011 - Ships Certificates › Load Lines (including Exemption)
Issued 19 July 2019
Resolved
The ring, lines and letters shall be painted in white or yellow on a dark ground or in black on a light ground. They shall also be permanently marked on the sides of the vessels to the satisfaction of the assigning authority. The marks shall be plainly visible and, if necessary, special arrangements shall be made for this purpose. Load line must be permanently marked to the sides of the vessel to the satisfaction of class.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 August 2019
Resolved 23 July 2019
Resolution: ABS conducted a Load Line survey and approved the punching of the LL
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 19 July 2019
Resolved
The tank overfill alarm required by paragraph (a) of this section must activate a visible and audible alarm so that it can be seen and heard on the vessel where cargo transfer is controlled and in the cargo deck area. Prior to cargo loading operations vessel must rectify the audio alarm to the satisfaction of the Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 July 2019
Resolution: Vessel submitted tech report
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 19 July 2019
Resolved
Where piping is used for gas turbine exhaust lines, Class II is required as a minimum. (See subpart 56.04 of this sub chapter.) Where the exhaust pressure exceeds 150 pounds per square inch, such as in closed cycle systems, Class I shall be used. Where ducting other than pipe is employed, the drawings and design data shall be submitted to substantiate suitability and safety for the intended service. Vessel must rectify the #1 STBRD engine exhaust leak to the satisfaction of the Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 August 2019
Resolved 22 July 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 19 July 2019
Resolved
Electric installations on vessels must ensure: Maintenance of services necessary for safety under normal and emergency conditions. Protection of passengers, crew, other persons, and the vessel from electrical hazards. Panel cover was not permanently affixed to the electrical panel.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 August 2019
Resolved 23 July 2019
Resolution: Vessel submitted pictures of secured electrical panel
Deck/Cargo › Holds/Tanks › Bulkhead
Issued 16 May 2018
Resolved
Pitted area on bulkhead between #4 port cargo tank and #4 port wing tank believed to be cause of cargo leak. Leak located 1' forward of FR 41, 7th longitudinal stiffener from tank top. Issued CG-835V allowing 1 time discharge of all cargo at Motiva Port Arthur prior to permenant repairs at Gulf Copper.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 May 2018
Resolved 14 August 2018
Stability › Watertight Integrity › Watertight Subdivision Standard
Issued 29 November 2017
Resolved
#5 Port Ballast Tank leaking into #4 Port Ballast Tank through watertight bulkhead.
Condition: Improper/Lack of Maintenance
Due 30 November 2017
Resolved 30 November 2017
Resolution: Placed 18" x 18" x 1/2" insert into watertight bulkhead between #4 and #5 Port Ballast Tanks.
Deck/Cargo › Ballast › Tank
Issued 15 January 2016
Resolved
Barge Caribbean sustained damage to the fwd portside ballast peak tank. Barge is allowed to transit to IMTT ST. Rose to offload cargo. No loading of cargo authorized. Barge allowed one transit to repair facility. Repairs to be conducted to the satisfaction of Class (ABS) and provide report to Sector New Orleans.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 15 January 2016
Resolved 23 January 2016
Resolution: Received ABS report attesting to proper repairs
Deck/Cargo › Cargo Stowage › General
Issued 20 April 2015
Resolved
Make permanent repairs to pinhole leak on the #4 stbd cargo tank. 835 issued and attached to case.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 19 May 2015
Resolved 19 June 2015
Resolution: Renewed and tested during extensive dry dock Activity# 5155168.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Closure Devices
Issued 2 October 2014
Resolved
Make permanent repairs to pipe supporting the reach rod on the main deck for the cross over valve in #3 stbd cargo tank to the satisfaction to the attending USCG marine inspector.
Due 2 November 2014
Resolved 6 October 2014
Resolution: Deteriorated pipes were removed and re-installed with new schedule 40 piping. All repairs were visually examined, tested and considered satisfactory by ABS.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Pump
Issued 28 August 2014
Resolved
During cargo discharge, stbd pump developed loss of structural integrity which resulted in the discharge of cargo on deck. Upon completion of discharging cargo with port pump, transit to Gulf Copper shipyard to affect permanent repairs to stbd cargo pump prior to onloading cargo.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 2 September 2014
Resolution: Shipyard affected permanent repairs to stbd and port cargo pump flange housings where leaks were detected. Witnessed satisfactory air test.
Deck/Cargo › Cargo Stowage › General
Issued 4 June 2014
Resolved
Vessel self reported having an 1/8"inch hole on deck above the #5 cargo hold tank. Issued an 835 to proceed to Gulf Copper for permanent repairs after offloading current cargo (No.6 oil). Extended due date on 835 to 18JUN2014 to accommodate vessel operations and preparations for repairs.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 20 June 2014
Resolved 20 June 2014
Resolution: Witnessed satisfactory NDT of 2'' x 3'' insert in #5 cargo hold tanktop. Placed COI back on barge.
Operations/Management › Cargo Transfer/Lightering › Fires, Matches, Smoking
Issued 12 November 2013
Resolved
Worn clutch on PT cargo pump. Once cover opened fire ignited with introduction of O2. RNR.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 27 November 2013
Resolved 12 November 2013
Resolution: Recieved Tech Report.
Engineering › Diesel Engine (auxiliary) › Pump, High Pressure (fuel injection)
Issued 4 September 2012
Resolved
Portside cargo pump engine's hand operated fuel priming system had three fuel lines that did not meet SAE J1942 standards. Vessel operator to provide documentation demonstrating compliance with SAE standards or remove and replace fuel hoses with approved hoses.
Action required: 705 - Other - as specified
Due 14 October 2012
Resolved 15 October 2012
Resolution: Rcvd, reviewed and accepted proper documentation and picture demonstrating replacement of non-approved hoses with SAE J1942 approved fuel hoses.
Deck/Cargo › Holds/Tanks › Bulkhead
Issued 30 June 2011
Resolved
#4 Starboard fuel tank is leaking product into adjacent ballast tank. Barge authorized to discharge cargo at Valero, MM 125 then proceed to Bollinger or Buck Kreihs Algiers for permanent repair.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 July 2011
Resolved 8 July 2011
Resolution: Repaired leak on weld on #4 starboard tank.
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 3 March 2006
Resolved
Install lagging on the exhaust manifolds on the bow thruster engine.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 3 April 2006
Resolved 6 March 2006
Resolution: Installed lagging.
Electrical › Electric Generation Source (service)
Issued 22 August 2002
Resolved
Failure of low lube oil alarms and overspeed trips LEGACY COMPONENT DESC: Generator
Action required: 705 - Other - as specified
Due 6 September 2002
Resolved 4 September 2002
Resolution: Conducted operational test of low lube oil pressure shutdowns on #1 and #2 generators. Test satisfactory.
Deck/Cargo › Cargo Heating
Issued 22 August 2002
Resolved
Alarms trips and emergency shutdowns not operational on port TFH. LEGACY COMPONENT DESC: Thermal Fluid Heater
Due 6 September 2002
Resolved 23 August 2002
Resolution: Third party testified to repair.
Pollution Prevention/Response › Prevention Equipment
Issued 22 August 2002
Resolved
Excessive oil in bow thruster bilge LEGACY COMPONENT DESC: Miscellaneous
Action required: 705 - Other - as specified
Due 6 September 2002
Resolved 3 September 2002
Resolution: Examined bow thruster bilge and found all water removed.
Construction/Loadline
Issued 10 May 2001
Resolved
Permanently attach/fix loadline marking to the hull, Class to verify the location of markings.
Condition: Unknown
Due 10 June 2001
Resolved 8 June 2001
Electrical
Issued 10 May 2001
Resolved
Reattach the lagging for the exhaust for the #2 generator.
Condition: Unknown
Due 10 June 2001
Resolved 8 June 2001
Electrical
Issued 10 May 2001
Resolved
Install blank covers for the missing breaker switches to the distribution panel located in the bow thruster space.
Condition: Unknown
Due 10 June 2001
Resolved 8 June 2001
Electrical
Issued 10 May 2001
Resolved
Provide non-conductive matting for all switchboards.
Condition: Unknown
Due 10 June 2001
Resolved 8 June 2001
Electrical
Issued 10 May 2001
Resolved
Provide a tachometer for the #2 generator. Presently the tachometer is missing.
Condition: Unknown
Due 10 June 2001
Resolved 8 June 2001
Engineering
Issued 21 July 1998
Resolved
PROVE PROPER OPERATION OF THE OVERSPEED TRIP AND LUBE OIL ALARMS ON BOTH GENERATORS.
Condition: Unknown
Due 21 July 1998
Resolved 21 July 1998
Deck/Cargo
Issued 21 July 1998
Resolved
PROVE PROPER OPERATION OF THE RISING STICKS OVERFILL PROTECTION ON ALL TEN (10) CARGO TANKS PRIOR TO LOADING NEXT U.S. PORT. (GRADE B AND LOWER CARGOES).
Condition: Unknown
Due 21 July 1998
Resolved 21 July 1998
Electrical
Issued 10 June 1997
Resolved
Demonstrate overspeeds on #1 and #2 SSG.
Condition: Unknown
Due 10 June 1997
Resolved 10 June 1997
Electrical
Issued 9 August 1996
Resolved
DEMONSTATE PROPER OPERATION OF OVERSPEED TRIPS FOR #1 & #2 SERVICE GENERATORS.
Condition: Unknown
Due 14 August 1996
Resolved 14 August 1996
Lifesaving
Issued 9 August 1996
Resolved
PROPERLY STENCIL RINGBUOY IN FORECASTLE.
Condition: Unknown
Due 14 August 1996
Resolved 14 August 1996
Deck/Cargo
Issued 9 August 1996
Resolved
MAKE PROPER REPAIRS TO CARGO PUMP EMERGENCY SHUTDOWN PULL WIRES.
Condition: Unknown
Due 14 August 1996
Resolved 14 August 1996
Deck/Cargo
Issued 9 August 1996
Resolved
PROVIDE COPY OF CARGO LINE DIAGRAM IN CARGO TRANSFER PROCEDURES.
Condition: Unknown
Due 14 August 1996
Resolved 14 August 1996
Engineering
Issued 9 August 1996
Resolved
PROVIDE OIL POLLUTION PLACARD AT BILGE AND BALLAST CONTROL STATION.
Condition: Unknown
Due 14 August 1996
Resolved 14 August 1996