Records from 1992 to 2025. Most recent: inspection, 9 December 2025.
Documentation record
Registered dimensions (L × B × D)104.9 ft × 34.0 ft × 19.0 ft
Registered tonnagegross 94 / net 64
ITC dimensions (L × B × D)104.9 ft × 34.0 ft × 19.0 ft
ITC tonnagegross 451 / net 135
BuilderAVONDALE INDUSTRIES INC · WESTWEGO, LA, UNITED STATES · built 1992
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted, Recreational, Registry
DocumentationValid · issued 19 February 2026 · expires 31 March 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it451 - Convention (Subpart B), Gross Ton
94 - Regulatory (Subpart C or D), Gross Ton
135 - Convention (Subpart B), Net Ton
64 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 55
9 December 2025
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8279580
8 December 2025
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8282461
23 October 2025
ISM SMC Audit · ISM Oversight
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8268189
29 September 2025
COI Inspection
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 8229532
11 October 2024
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8012361
27 September 2024
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 8017357
15 August 2024
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7981902
2 August 2024
Damage Survey
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7972706
9 January 2024
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7846843
29 August 2023
Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7780133
5 July 2023
Deficiency Check · ISM Oversight · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7734010
22 December 2022
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7589130
16 December 2021
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7356095
29 May 2020
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6963397
6 April 2020
Initial Certification · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6935942
7 August 2018
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6510428
23 December 2016
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6072073
7 October 2014
MARPOL Annex VI Survey · MTSA/ISPS Verification · MARPOL Annex I Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4996525
7 October 2014
DAPI Audit · MTSA Verification · Industry Initiated Exam · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5002356
18 June 2013
MARPOL Annex I Examination · MARPOL Annex VI Survey
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4623226
15 May 2012
Deficiency Check · MARPOL Annex I Examination · MARPOL Annex VI Survey
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4300974
28 June 2011
MTSA/ISPS Verification · MARPOL Annex I Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4052205
5 May 2010
Type not recorded
No type recorded · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 3731733
23 March 2010
Industry Initiated Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3701445
9 February 2010
MTSA/ISPS Verification · MARPOL · Administration
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3674303
7 July 2009
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3526795
9 March 2009
MTSA/ISPS Verification · Administration
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3426340
20 May 2008
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3212089
11 May 2008
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3211719
15 April 2008
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3206536
20 July 2007
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3001644
25 June 2007
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3001524
7 September 2006
Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2772840
24 July 2006
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2723313
24 July 2006
Administrative Inspection
Administrative · Marine Safety Center (MSC) · Activity 2723361
18 November 2003
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1951409
1 October 2000
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 133868
11 January 2000
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 213462
13 December 1999
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 770475
8 December 1999
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 200822
14 May 1998
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 220059
20 February 1998
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2527
28 April 1996
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 29328
23 April 1996
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 54736
15 January 1996
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 65176
30 September 1995
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 758343
13 September 1995
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 200819
13 July 1995
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 131308
15 June 1995
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 30787
15 September 1994
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 3318
26 July 1994
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 682368
21 July 1994
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 13316
8 May 1992
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 79047
8 May 1992
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 181521
6 May 1992
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 151506
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 11 October 2024
No resolution recorded
The vessel is equipped, and maintained to conform to the rules of a recognized classification society appropriate for the intended service and routes, but not classed. Vessel had a soft patch temporary repair between fuel tank and machinery space. Enact permanent repairs to the satisfaction of the attending Marine Inspector.
Action required: 705 - Other - as specified
Due 11 October 2024 — due date passed with no resolution recorded
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 7 September 2023
Resolved
Issued deficiency for a hole identified in the aft bulkhead of the engine room under the stbd shaft. Vessel was told to place a temp repair via splash zone on it until it could be repaired at the vessels next scheduled DD exam.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 September 2025
Resolved 11 October 2024
Resolution: SECNOLA verified identified hole was temp patched but 835 was never issued and as a result was not corrected during scheduled dry dock earlier this year 2024. SECNOLA is closing this deficiency and will be issuing a new 835 under activity number: 8012361
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 5 July 2023
Resolved
Fuel shutoff requirements to stop the flow of fuel in the event of a fire or break in the fuel line, a remote fuel shutoff valve must be fitted on any fuel line that supplies fuel directly to a propulsion engine or generator prime mover, be installed in the fuel piping directly outside of the fuel oil supply tank,be operable from a safe place outside the space where the valve is installed and be legibly marked. Fuel valve was inoperable, show proper operation to the satisfaction of the attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 19 July 2023
Resolved 5 July 2023
Resolution: Received documentary evidence that the fuel shut off valves are fully operational and the crew has received training on operation and resetting of tripped valves.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 5 July 2023
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons on-board under normal and emergency conditions. Vessels bilges were unkempt and had excessive oil present. Identify and arrest leaks and clean bilges to the satisfaction of the attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 19 July 2023
Resolved 7 July 2023
Resolution: Documentary evidence was received showing bilges clear of flammable material.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 22 December 2022
Resolved
Pressure vessels over 5 cubic feet in volume and over 15 pounds per square inch maximum allowable working pressure (MAWP) must be equipped with an indicating pressure gauge (in a readily visible location) and with one or more spring-loaded relief valves. The total relieving capacity of such relief valves must prevent pressure from exceeding the MAWP, as established by the manufacturer, by more than 10 percent. MAWP on start air tanks is 200psi and relief valves were set to 235psi.
46 CFR 143.300(a)
Condition: Improper Installation
Action required: 60 - Rectify deficiencies prior to movement
Due 22 December 2022
Resolved 22 December 2022
Resolution: New pressure relief valves were installed.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 22 December 2022
Resolved
Each towing vessel must be maintained and operated so as to minimize fire hazards and to ensure the following: (a) All bilges and void spaces are kept free from accumulation of combustible and flammable materials and liquids insofar as practicable. Racor filters did not have plug to prevent fuel oil leak into bilge.
46 CFR 142.220(a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 January 2023
Resolved 22 December 2022
Resolution: Plugs were installed on Rayco fuel filters.