CAPT. BUD BISSO

CAPT. BUD BISSO is a 1992 towing vessel. The Coast Guard has recorded 55 inspections since 1992, most recently in December 2025, along with 6 deficiencies — 1 with no resolution recorded — and 4 casualty investigations between 2008 and 2025.

Records from 1992 to 2025. Most recent: inspection, 9 December 2025.

Built
1992
Last inspected
9 December 2025
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Towing Vessel class in Maury's sources begin in 1980.

Inspection record

Last inspected 9 December 2025
…with no type recorded30
…past their stated due date1
Operational controls None recorded without a removal date
Years with a record 25 calendar years (1992–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9034834
WCW4130
370011
Flag
UNITED STATES
Maury page id
psix-370011

Documentation record

Registered dimensions (L × B × D)104.9 ft × 34.0 ft × 19.0 ft
Registered tonnagegross 94 / net 64
ITC dimensions (L × B × D)104.9 ft × 34.0 ft × 19.0 ft
ITC tonnagegross 451 / net 135
BuilderAVONDALE INDUSTRIES INC · WESTWEGO, LA, UNITED STATES · built 1992
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted, Recreational, Registry
DocumentationValid · issued 19 February 2026 · expires 31 March 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it451 - Convention (Subpart B), Gross Ton
94 - Regulatory (Subpart C or D), Gross Ton
135 - Convention (Subpart B), Net Ton
64 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1980 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 11

Inspection history · 55

9 December 2025 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8279580
8 December 2025 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8282461
23 October 2025 ISM SMC Audit · ISM Oversight
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8268189
29 September 2025 COI Inspection
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 8229532
11 October 2024 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8012361
27 September 2024 Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 8017357
15 August 2024 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7981902
2 August 2024 Damage Survey
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7972706
9 January 2024 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7846843
29 August 2023 Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7780133
5 July 2023 Deficiency Check · ISM Oversight · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7734010
22 December 2022 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7589130
16 December 2021 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7356095
29 May 2020 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6963397
6 April 2020 Initial Certification · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6935942
7 August 2018 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6510428
23 December 2016 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6072073
7 October 2014 MARPOL Annex VI Survey · MTSA/ISPS Verification · MARPOL Annex I Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4996525
7 October 2014 DAPI Audit · MTSA Verification · Industry Initiated Exam · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5002356
18 June 2013 MARPOL Annex I Examination · MARPOL Annex VI Survey
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4623226
15 May 2012 Deficiency Check · MARPOL Annex I Examination · MARPOL Annex VI Survey
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4300974
28 June 2011 MTSA/ISPS Verification · MARPOL Annex I Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4052205
5 May 2010 Type not recorded
No type recorded · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 3731733
23 March 2010 Industry Initiated Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3701445
9 February 2010 MTSA/ISPS Verification · MARPOL · Administration
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3674303
7 July 2009 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3526795
9 March 2009 MTSA/ISPS Verification · Administration
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3426340
20 May 2008 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3212089
11 May 2008 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3211719
15 April 2008 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3206536
20 July 2007 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3001644
25 June 2007 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3001524
7 September 2006 Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2772840
24 July 2006 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2723313
24 July 2006 Administrative Inspection
Administrative · Marine Safety Center (MSC) · Activity 2723361
18 November 2003 Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1951409
1 October 2000 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 133868
11 January 2000 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 213462
13 December 1999 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 770475
8 December 1999 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 200822
14 May 1998 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 220059
20 February 1998 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2527
28 April 1996 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 29328
23 April 1996 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 54736
15 January 1996 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 65176
30 September 1995 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 758343
13 September 1995 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 200819
13 July 1995 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 131308
15 June 1995 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 30787
15 September 1994 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 3318
26 July 1994 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 682368
21 July 1994 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 13316
8 May 1992 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 79047
8 May 1992 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 181521
6 May 1992 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 151506

Deficiency record · 6

02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 11 October 2024 No resolution recorded
The vessel is equipped, and maintained to conform to the rules of a recognized classification society appropriate for the intended service and routes, but not classed. Vessel had a soft patch temporary repair between fuel tank and machinery space. Enact permanent repairs to the satisfaction of the attending Marine Inspector.
Action required: 705 - Other - as specified
Due 11 October 2024 — due date passed with no resolution recorded
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 7 September 2023 Resolved
Issued deficiency for a hole identified in the aft bulkhead of the engine room under the stbd shaft. Vessel was told to place a temp repair via splash zone on it until it could be repaired at the vessels next scheduled DD exam.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 September 2025
Resolved 11 October 2024
Resolution: SECNOLA verified identified hole was temp patched but 835 was never issued and as a result was not corrected during scheduled dry dock earlier this year 2024. SECNOLA is closing this deficiency and will be issuing a new 835 under activity number: 8012361
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 5 July 2023 Resolved
Fuel shutoff requirements to stop the flow of fuel in the event of a fire or break in the fuel line, a remote fuel shutoff valve must be fitted on any fuel line that supplies fuel directly to a propulsion engine or generator prime mover, be installed in the fuel piping directly outside of the fuel oil supply tank,be operable from a safe place outside the space where the valve is installed and be legibly marked. Fuel valve was inoperable, show proper operation to the satisfaction of the attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 19 July 2023
Resolved 5 July 2023
Resolution: Received documentary evidence that the fuel shut off valves are fully operational and the crew has received training on operation and resetting of tripped valves.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 5 July 2023 Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons on-board under normal and emergency conditions. Vessels bilges were unkempt and had excessive oil present. Identify and arrest leaks and clean bilges to the satisfaction of the attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 19 July 2023
Resolved 7 July 2023
Resolution: Documentary evidence was received showing bilges clear of flammable material.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 22 December 2022 Resolved
Pressure vessels over 5 cubic feet in volume and over 15 pounds per square inch maximum allowable working pressure (MAWP) must be equipped with an indicating pressure gauge (in a readily visible location) and with one or more spring-loaded relief valves. The total relieving capacity of such relief valves must prevent pressure from exceeding the MAWP, as established by the manufacturer, by more than 10 percent. MAWP on start air tanks is 200psi and relief valves were set to 235psi. 46 CFR 143.300(a)
Condition: Improper Installation
Action required: 60 - Rectify deficiencies prior to movement
Due 22 December 2022
Resolved 22 December 2022
Resolution: New pressure relief valves were installed.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 22 December 2022 Resolved
Each towing vessel must be maintained and operated so as to minimize fire hazards and to ensure the following: (a) All bilges and void spaces are kept free from accumulation of combustible and flammable materials and liquids insofar as practicable. Racor filters did not have plug to prevent fuel oil leak into bilge. 46 CFR 142.220(a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 January 2023
Resolved 22 December 2022
Resolution: Plugs were installed on Rayco fuel filters.

Casualty record · 4

11 May 2008Routine · role: Involved in a Marine Casualty · activity 3211719
23 December 2016Routine · role: Transiting Vicinity of Primary Subject · activity 6072073
27 September 2024Routine · role: Involved in a Marine Casualty · activity 8017357
8 December 2025Routine · role: Involved in a Marine Casualty · activity 8282461
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.