Records from 1995 to 2026. Most recent: inspection, 11 June 2026.
Inspection history · 30
11 June 2026
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 8401303
4 August 2025
Deficiency Check
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 8204834
22 April 2025
Deficiency Check · COI Inspection · Administrative Inspection · DAPI Audit
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 8117315
14 August 2024
Type not recorded
No type recorded · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7985617
15 May 2024
Annual Inspection · Administrative Inspection · MTSA Verification
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7913296
14 December 2023
Drydock Exam · Deficiency Check · Internal Structural Exam
Physical examination · Detached Duty Office Seward · USCG Arctic District (CGD-A) · Activity 7839560
20 April 2023
Annual Inspection · Administrative Inspection · MTSA Verification · Deficiency Check
Physical examination · Detached Duty Office Seward · USCG Arctic District (CGD-A) · Activity 7672283
13 December 2022
Special · Hull Examination · Drydock Exam · Examination of Repairs · Internal Structural Exam · Administrative Inspection
Physical examination · Detached Duty Office Seward · USCG Arctic District (CGD-A) · Activity 7583807
2 November 2022
Type not recorded
No type recorded · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7759865
29 May 2022
Type not recorded
No type recorded · Marine Safety Unit Kodiak · USCG Arctic District (CGD-A) · Activity 7466975
11 May 2022
MTSA Verification · Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 7467071
4 March 2022
Examination of Repairs · Administrative Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7406186
18 January 2022
Administrative Inspection
Administrative · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7382137
13 October 2021
Type not recorded
No type recorded · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7332825
26 April 2021
Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7182998
14 May 2020
Administrative Inspection · Initial Certification
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 6956224
5 March 2019
Examination of Repairs · Spot Check · Internal Structural Exam · Drydock Exam · Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 6642232
24 September 2018
Type not recorded
No type recorded · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6552857
19 June 2018
Type not recorded
No type recorded · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6505218
30 April 2018
Type not recorded
No type recorded · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6504898
20 February 2015
Liferaft Servicing
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 5072140
24 November 2013
Type not recorded
No type recorded · Suspension & Revocation National Center of Expertise · Activity 5114221
8 May 2012
Administration
Administrative · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 4779867
23 May 2011
Administrative Inspection · Deficiency Check
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 4020333
21 December 2010
Administration
Administrative · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 3916617
8 November 2006
Uninspected Other · MTSA Verification
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 2838295
30 January 2004
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2015611
11 June 2001
Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 63736
31 May 1997
Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 226976
16 March 1995
Deadweight Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1138295
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 12 June 2026
Resolved
Alcohol test strips onboard were expired. Vessel rep provided new strips while MI onboard.
Action required: 10 - Deficiency Rectified
Resolved 11 June 2026
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 4 August 2025
Resolved
Propulsion machinery, including main engines, reduction gears, shafting, bearings and electrical equipment must be maintained to ensure proper operations. Vessel reported signs of wear on the starboard reduction gear that is threatening the reduction gears ability to operate. Vessel is required to maintain the starboard reduction gear in a manner that ensures proper operation.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 September 2025
Resolved 15 August 2025
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 21 May 2025
Resolved
Properly terminated bare wire on top bunk in the main deck port side berth.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 June 2025
Resolved 22 May 2025
Resolution: all sat
10 - Safety of Navigation › N/A - No Subsystem › Automatic radar plotting aid (ARPA)
Issued 21 May 2025
Resolved
Prove that Radar acquires target and show AIS info.
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 May 2025
Resolved 22 May 2025
Resolution: all sat
10 - Safety of Navigation › N/A - No Subsystem › Electronic charts (ECDIS)
Issued 21 May 2025
Resolved
Provide electronic chart that meet the requirement of NVIC 01-16
Action required: 60 - Rectify deficiencies prior to movement
Due 20 May 2025
Resolved 22 May 2025
Resolution: all sat
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 21 May 2025
Resolved
Proved Bell or Gong that meets the requirements of 33 CFR 86.02
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 June 2025
Resolved 22 May 2025
Resolution: all sat
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 21 May 2025
Resolved
Replace broken glass in the CO2 pull station.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 June 2025
Resolved 22 May 2025
Resolution: all sat
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 21 May 2025
Resolved
Properly install hydrostatic release in life raft to insure life raft releases from the vessel.
Action required: 10 - Deficiency Rectified
Due 20 May 2025
Resolved 20 May 2025
Resolution: all sat
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Radio (including exemption)
Issued 21 May 2025
Resolved
Proved FCC Bridge to bridge and radio safety telephoney with the current call sign
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 May 2025
Resolved 22 May 2025
Resolution: all sat
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 21 May 2025
Resolved
Proved updated NOAA EPIRB registration with corrected call Sign and MSSI #
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 May 2025
Resolved 22 May 2025
Resolution: all sat
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 21 May 2025
Resolved
Install plugs/ caps on all drain valves on fuel filters in engine room.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 June 2025
Resolved 22 May 2025
Resolution: all sat
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 21 May 2025
Resolved
Label fuel oil transfer pump shut off on starboard side of tug on main deck.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 June 2025
Resolved 2 June 2025
Resolution: all sat
11 - Life Saving Appliances › N/A - No Subsystem › Immersion suits
Issued 16 May 2024
Resolved
Immersion suits carried on towing vessels must meet the requirements of § 199.70(c) and (d) of this chapter. Each immersion suit or anti-exposure suit must have a lifejacket light approved under approval series 161.112 securely attached to the front shoulder area of the immersion suit or anti-exposure suit. Two immersion suits were found to have inoperable lights. 46 CFR 141.350(b) & 46 CFR 199.70(c)(4)(i)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 May 2024
Resolved 29 August 2024
Resolution: Received photographic evidence showing the replacement of immersion suit lights
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 16 May 2024
Resolved
A towing vessel 79 feet or more in length must carry four lifebuoys, with one lifebuoy located on each side of the operating station. Lifebuoys must be at least 610 millimeters (24 inches) in diameter. Two lifebuoys on the port side had deteriorated/broken plugs. 46 CFR 141.360(a)(3)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 May 2024
Resolved 29 August 2024
Resolution: Received photographic evidence showing the replacement of liferings
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 16 May 2024
Resolved
Piping and machinery components that exceed 220 °C (428 °F), including fittings, flanges, valves, exhaust manifolds, and turbochargers, must be insulated. Lagging on the stbd generator needs replacement. 46 CFR 143.220(b)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 May 2024
Resolved 29 August 2024
Resolution: Received photographic evidence showing the replacement of exhaust lagging
08 - Alarms › N/A - No Subsystem › General alarm
Issued 16 May 2024
Resolved
The engine room must have general alarm identified with a sign that reads: “Attention General Alarm—When Alarm Sounds or Flashes Go to Your Station." Signage is missing in the engine room. 46 CFR 143.235(b)(3)
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 May 2024
Resolved 29 August 2024
Resolution: Received photographic evidence showing the placement of general alarm signage
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 16 May 2024
Resolved
Each towing vessel must have a low fuel level alarm, if fitted with a day tank. Vessel's day tank (2C) does not have low fuel level alarm. 46 CFR 143.230(a)(7)
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 June 2024
Resolved 20 May 2025
Resolution: tested all sat
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 21 April 2023
Resolved
Mechanical and electrical equipment must be maintained to ensure proper operation. The machinery space ventilation controller does not secure when the remote e-stops are actuated.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 May 2023
Resolved 8 May 2023
Resolution: Corrected.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 21 April 2023
Resolved
Piping for flammable or combustible liquid must be fitted wit isolation valves that are clearly marked. All fuel shut-off valves are not labeled to identify what is open or closed.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 May 2023
Resolved 8 May 2023
Resolution: Corrected.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 21 April 2023
Resolved
All spaced deemed restricted must be properly labeled. There are multiple placards that need to be replaced.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 May 2023
Resolved 8 May 2023
Resolution: Corrected.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 25 January 2023
Resolved
At the next scheduled drydock, the vessel shall be subject to a detailed marine survey to identify any damage to the internal structures and hull plating. All assessed damages shall then be completed prior to receiving credit for drydock and internal structural examinations.
Action required: 705 - Other - as specified
Resolved 19 December 2023
Resolution: Complete.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 20 May 2020
Resolved
Make permanent repairs to bilge piping at manifold.
Action required: 705 - Other - as specified
Due 30 April 2021
Resolved 29 April 2021
Resolution: repaired
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil and oily mixtures from machinery spaces
Issued 20 May 2020
Resolved
Vessel is required to have fixed piping with an outlet on deck and a pump to offload oily waste mixture to a reception facility.
Action required: 705 - Other - as specified
Due 30 April 2021
Resolved 29 April 2021
Resolution: installed
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 10 April 2019
Resolved
Repaint vessel name on life rings.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 May 2019
Resolved 22 May 2020
11 - Life Saving Appliances › N/A - No Subsystem › Line-throwing appliance
Issued 10 April 2019
Resolved
Provide required auxiliary line for line throwing device.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 May 2019
Resolved 22 May 2020
14 - Pollution Prevention › 141 - MARPOL Annex I › Control of discharge
Issued 10 April 2019
Resolved
Add verbiage to Oil Transfer procedures for containment on fuel vents during transfers
Action required: 703 - Prior to bunkering operations
Resolved 22 May 2020
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 10 April 2019
Resolved
Conduct required tests and inspections in 143.245 and record during the 2019 operating season.
Action required: 705 - Other - as specified
Due 31 October 2019
Resolved 22 May 2020
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 10 April 2019
Resolved
Conduct VGP grey water and black water inspections and submit required annual reports to EPA as required by company SMS
Action required: 705 - Other - as specified
Due 31 October 2019
Resolved 22 May 2020