Records from 1981 to 2009. Most recent: inspection, 12 July 2009.
Inspection history · 67
12 July 2009
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3535598
5 March 2009
Annual Inspection · Hull Examination · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3432428
6 May 2008
COI Inspection · Examination of Repairs · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3199825
2 April 2007
Re-Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2976384
9 December 2005
Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2547185
15 August 2005
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2463859
22 June 2005
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2399412
11 April 2005
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2327656
8 September 2004
Re-Inspection · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2190644
14 April 2004
Examination of Repairs · Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2043797
20 August 2003
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1882047
16 June 2003
Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1818726
9 June 2003
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1813005
11 May 2003
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1812949
24 January 2003
COI Inspection
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 1720449
16 September 2002
Type not recorded
No type recorded · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 1623640
9 July 2001
COI Inspection · Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1422042
26 July 2000
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1052324
18 May 2000
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1365767
17 May 2000
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 818268
29 March 2000
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 816570
8 March 2000
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1046182
1 March 2000
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 40931
4 June 1999
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 804933
26 May 1999
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 800877
1 April 1999
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1119276
30 March 1999
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1116504
1 March 1999
Examination of Repairs · Hull Examination · COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1415109
17 August 1998
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1130846
16 August 1998
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 83361
30 May 1997
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1443873
20 February 1997
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 123117
21 January 1997
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1100840
14 January 1997
Examination of Repairs
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1099609
10 January 1997
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 36149
10 January 1997
Damage Survey
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1100538
25 July 1996
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 54703
30 May 1996
COI Inspection · Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1353930
21 January 1996
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 55425
10 January 1996
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 881782
29 November 1995
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 882552
8 September 1995
Inclining Experiment
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1191458
3 April 1995
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1360057
18 November 1994
Examination of Repairs
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1359986
29 April 1994
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1456164
22 September 1993
Hull Examination · Damage Survey
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1353479
13 September 1993
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 80070
13 September 1993
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 102632
13 September 1993
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 165886
27 April 1993
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1435354
8 January 1993
Examination of Repairs
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1451832
4 June 1992
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 946113
29 May 1992
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 958911
24 March 1992
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 4256
9 December 1991
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1255095
31 July 1991
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1252913
28 May 1991
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 931732
1 May 1991
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 904024
3 April 1991
COI Inspection · Examination of Repairs
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1239472
26 April 1990
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 919271
5 July 1989
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1347209
31 May 1989
Examination of Repairs · Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1348445
28 April 1989
COI Inspection · Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1197749
22 September 1988
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1042992
2 March 1985
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1007081
2 March 1983
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 966523
8 June 1981
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1271588
Deck/Cargo › Cargo Transfer (solid) › General
Issued 9 April 2009
Resolved
Crane inspection was expired. Conduct annual crane inspection.
Due 9 May 2009
Resolved 12 June 2009
Resolution: Crane inspection paperwork was present. Satisfactory to Marine Inspector who attended.
Lifesaving › Inflatable Liferafts › Servicing
Issued 5 March 2009
Resolved
Annual Liferaft service was not completed. Have liferaft serviced.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 June 2009
Resolution: Witnessed paperwork and liferafts. Satisfactory to attended Marine Inspector.
Lifesaving › Hand Flares › Expired
Issued 5 March 2009
Resolved
Distress signals were expired. Replace distress signals.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 June 2009
Resolution: New distress signals were on board.
Documentation › Certificates/Documents › FCC SSL
Issued 5 March 2009
Resolved
Vessel did not have FCC license. Provide license for vessel.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 June 2009
Resolution: New FCC license on board vessel. Satisfactory to Marine Inspector which attended.
Electrical › Electric Generation Source (service) › Number of Sources
Issued 26 April 2005
Resolved
Submit plans to MSC, IAW 46 CFR 110.25, for approval of new generator installation. Plans shall be submitted within two weeks of this issue date. Installation of the generators shall commence by 26 June 2005.
Action required: 705 - Other - as specified
Due 21 July 2005
Resolved 12 August 2005
Resolution: 12 Aug 2005: Approved plans were received from MSC and generators were installed according to plans. All wiring, and panels were inspected. Both generators were run under full load and over-speed trips were checked. All sat.
cleared 835 for generator.
Accommodation/Occupational Safety › Sleeping Accommodations › Berth
Issued 26 April 2005
Resolved
Provide Approval Letter for installed portable quarters to supplement the attached data plate.
Action required: 705 - Other - as specified
Due 12 September 2005
Resolved 9 December 2005
Fire Fighting
Issued 24 January 2003
Resolved
Provide 2 compete firefighting outfits in accordance with 46 CFR 96.35-10
Action required: 17 - Rectify deficiencies prior to departure
Due 13 June 2003
Resolved 9 May 2003
Fire Fighting
Issued 24 January 2003
Resolved
Post fire control plan in accordance with 46 CFR 97.36-1
Due 13 June 2003
Resolved 9 May 2003
Lifesaving
Issued 24 January 2003
Resolved
Post muster list in accordance with 46 CFR 199.80.
Due 13 June 2003
Resolved 9 May 2003
Engineering
Issued 24 January 2003
Resolved
Provide proper relief valves on fire main in accordance with 46 CFR 54.15-10
Due 13 June 2003
Resolved 9 May 2003
Accommodation/Occupational Safety
Issued 24 January 2003
Resolved
Remove all ceilings, linings and insulation that are covered with non-approved materials. Replacement materials shall be installed in accordance with 46 CFR 92.07-10 (d) (7)
Due 13 June 2003
Resolved 9 May 2003
Engineering
Issued 24 January 2003
Resolved
Renew all corroded oil transfer piping in accordance with 46 CFR 56.
Due 13 June 2003
Resolved 9 May 2003
Accommodation/Occupational Safety
Issued 9 July 2001
Resolved
PROVIDE HOSPITAL SPACE IAW 46 CFR 92.20-35.
Condition: Unknown
Due 8 September 2001
Resolved 9 May 2003
Lifesaving
Issued 9 July 2001
Resolved
PROVIDE EPIRB AND REGISTER IT WITH NOAA.
Condition: Unknown
Due 8 September 2001
Resolved 9 May 2003
Documentation
Issued 9 July 2001
Resolved
PROVIDE 4 CERTIFICATED LIFEBOATMAN (TRAINED TO 46 CFR 10.205(g)) AND 1 PERSON DESIGNATED AS MASTER FOR 46 CFR 199.80-199.100.
Condition: Unknown
Due 8 September 2001
Resolved 9 May 2003
Fire Fighting
Issued 9 July 2001
Resolved
PROVIDE 1 MORE FIRE PUMP AND ENSURE FIRE MAIN SYSTEM MEETS REQUIREMENTS OF 46 CFR 95.10.
Condition: Unknown
Due 8 September 2001
Resolved 9 May 2003
Accommodation/Occupational Safety
Issued 9 July 2001
Resolved
INSTALL 12 BUNK LIGHTS AND THEIR COVERS IN THE 12 MAN PORTABLE QUARTERS UNIT.
Condition: Unknown
Due 9 August 2001
Resolved 9 May 2003
Deck/Cargo
Issued 18 May 2000
Resolved
AS PER 46CFR 58.30-20 (a-d) REPLACE ALL HYDRAULIC FLEXIBLE LINES SO AS NO LENGTH OF ANY HOSE EXCEEDS 30 INCHES.
Condition: Unknown
Due 18 May 2000
Resolved 18 May 2000
Electrical
Issued 18 May 2000
Resolved
AS PER 46CFR 111.30-5 (b) INSTALL OVERHEAD ON SWITCHBOARD TO MAKE SWITCHBOARD DRIP PROOF.
Condition: Unknown
Due 18 May 2000
Resolved 18 May 2000
Construction/Loadline
Issued 8 March 2000
Resolved
VSL TO PROCEED TO C&C MARINE, HARVEY CANAL, HARVEY, LA TO MAKE PERMANENT REPAIRS TO 02 HOLES IN STERN RAKE. VSL NOT TO ENGAGE IN ANY WORK FOR HIRE OR CARRY ANY CARGO UNTIL PERMANENT REPAIRS ARE MADE TO THE SATISFACTION OF AN ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 8 March 2000
Resolved 8 March 2000
Electrical
Issued 1 March 1999
Resolved
LABEL ALL BREAKER PANELS IN AFT MACHINERY HOUSE WITH CIRCUTS AMPERAGES.
Condition: Unknown
Due 1 March 1999
Resolved 1 March 1999
Lifesaving
Issued 1 March 1999
Resolved
PROPERLY SUPPORT ALL PIPING IN MACHINERY HOUSES.
Condition: Unknown
Due 1 March 1999
Resolved 1 March 1999
Electrical
Issued 1 March 1999
Resolved
PROPERLY SECURE ALL APPLIANCES IN GALLEY; PROPERLY WIRE ALL APPLIANCES IN GALLEY; LABEL STOVE BREAKER.
Condition: Unknown
Due 1 March 1999
Resolved 1 March 1999
Lifesaving
Issued 1 March 1999
Resolved
REPAIR LADDER IN TRUNK TO STORAGE ROOM.
Condition: Unknown
Due 1 March 1999
Resolved 1 March 1999
Accommodation/Occupational Safety
Issued 1 March 1999
Resolved
REMOVE OR PROVIDE USCG APPROVED ACCOMODATIONS FOR NUMBER OF PERSONS ALLOWEDON COI. REMOVAL TO BE COMPLETED OR RENEWAL TO BE COMPLETED WITHIN SIX MONTHS AS PER CID. SMOKE DETECTORS AND PROPER WIRING TO BE COMPLETED IAW SUBCHAPTER J.
Condition: Unknown
Due 1 March 1999
Resolved 1 March 1999
Lifesaving
Issued 1 March 1999
Resolved
PROVE ALL HANDRAILS ABOVE MAIN DECK.
Condition: Unknown
Due 1 March 1999
Resolved 1 March 1999
Lifesaving
Issued 1 March 1999
Resolved
SECURE PAINT LOCKER TO DECK.
Condition: Unknown
Due 1 March 1999
Resolved 1 March 1999
Electrical
Issued 1 March 1999
Resolved
PROPERLY SECURE ALL LOOSE WIRING; INSTALL CORROSION-RESISTANT WIRE TIES THROUGHOUT VESSEL.
Condition: Unknown
Due 1 March 1999
Resolved 1 March 1999
Lifesaving
Issued 1 March 1999
Resolved
INSTALL LAGGING ON ALL ENGINES WHERE MISSING.
Condition: Unknown
Due 1 March 1999
Resolved 1 March 1999
Engineering
Issued 1 March 1999
Resolved
REPLACE ALL FUEL AND LUBE OIL HOSES OVER 30" WITH HARD PIPING.
Condition: Unknown
Due 1 March 1999
Resolved 1 March 1999
Construction/Loadline
Issued 14 January 1997
Resolved
REMOVED SLUGGED WELD IWO #4 & #5 PORT VOID AND MAKE PERMANENT REPAIRS TO THE WATERTIGHT BULKHEAD.
Condition: Unknown
Due 14 January 1997
Resolved 14 January 1997
Construction/Loadline
Issued 10 January 1997
Resolved
Crop and renew sideshell plate on portside where holed in way of #5 port void and sideshell at blkh between #4 and 5 port voids. Repairs to be in accordance with standard marine practice. CG inspector to inspect final repairs.
Condition: Unknown
Due 17 January 1997
Resolved 17 January 1997
Documentation
Issued 30 May 1996
Resolved
PROVIDE ON BOARD AN APPROVED VESSEL SOPEP WITH CG APPROVAL LETTER.
Condition: Unknown
Due 30 July 1996
Resolved 7 June 1996
Documentation
Issued 3 April 1995
Resolved
Unknown Component - Unknown Cause/Condition
Condition: Unknown
Due 3 April 1995
Resolved 3 April 1995
Documentation
Issued 27 April 1993
Resolved
UPON COMPLETION OF PLANNED MODIFICATION/REHABILITATION PER LETTER TO MSC (THREE PHASES), CONDUCT INCLINING EXPERIMENT AND READMEASUREMENT. RESULTS TO BE APPROVED BY MSC.
Condition: Unknown
Due 27 April 1993
Resolved 27 April 1993
Electrical
Issued 29 May 1992
Resolved
LAG/INSULATE EXHAUST LINE ON AFT S/S GENERATOR TO ELIMINATE PERSONELL HAZZARD.
Condition: Unknown
Due 29 June 1992
Resolved 4 June 1992
Electrical
Issued 29 May 1992
Resolved
REPAIR RPM GAGE (TACH) ON AFT S/S GENERATOR AND PROVE PROPER OPERATION OF OVERSPEED TRIP ON SAME.
Condition: Unknown
Due 29 June 1992
Resolved 4 June 1992
Fire Fighting
Issued 3 April 1991
Resolved
PROVIDE SERVICING OF ALL FIRE EXTINGUISHERS AND PROVIDE A COPY OF THE SERVICING REPORT TO THE COGNIZANT OCMI.
Condition: Unknown
Due 3 April 1991
Resolved 3 April 1991
Electrical
Issued 3 April 1991
Resolved
PROVE PROPER OPERATION OF THE AFT GENERATOR OVERSPEED DEVICE (RATED AT_x001C_ 1800 RPM)
Condition: Unknown
Due 3 April 1991
Resolved 3 April 1991
Electrical
Issued 3 April 1991
Resolved
PROVIDE BATTERY BOXES (LEAD OR FIBERGLASS LINED) FOR ALL BATTERIES
Condition: Unknown
Due 3 April 1991
Resolved 3 April 1991
Documentation
Issued 3 April 1991
Resolved
PROVIDE COPY OF ABS REPAIR/SURVEY REPORT TO THE COGNIZANT OCMI.
Condition: Unknown
Due 3 April 1991
Resolved 3 April 1991
Deck/Cargo
Issued 28 April 1989
Resolved
REPAIR OR RENEW TWO(2) PRESSURE VESSEL RELIEF VALVES AND PROVE PROPER OPERATION TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR. ALSO OPENBOTH PRESSURE VESSELS FOR INTERNAL EXAMINATION BY MARINE INSPECTOR.
Condition: Unknown
Due 28 April 1989
Resolved 28 April 1989
Construction/Loadline
Issued 28 April 1989
Resolved
MAKE PERMANENT REPAIRS TO CAMAGED #5 STERN VERTICAL FROM PORT SIDE SHELL AND SURROUNDING STRUCTURAL MEMBERS IN STERMOST PORT VOID IN WAY OF THE STERN LOG.
Condition: Unknown
Due 28 April 1989
Resolved 28 April 1989
Construction/Loadline
Issued 28 April 1989
Resolved
MAKE PERMANENT REPAIRS TO FIRST FRAME FWD OF AFT BULKHEAD WHERE IT IS TRIPPED BETWEEN THE FIRST AND SECOND LOGITUDINAL DOWN FROM THE DECK IN #3 STARBOARD VOID
Condition: Unknown
Due 28 April 1989
Resolved 28 April 1989