Records from 1999 to 2023. Most recent: inspection, 19 September 2023.
Documentation record
Registered dimensions (L × B × D)45.0 ft × 14.5 ft × 7.0 ft
Registered tonnagegross 30 / net 24
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderGULF CRAFT, INC. · PATTERSON, LA, UNITED STATES · built 1999
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 14 July 2026 · expires 31 August 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it30 - Simplified, Gross Ton
24 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 21
19 September 2023
Administrative Inspection · Examination of Repairs
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7794613
25 April 2023
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7675604
30 August 2021
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7340212
21 July 2020
Deficiency Check · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6998635
10 September 2019
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6797661
22 August 2018
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6514230
23 July 2018
Internal Structural Exam · Drydock Exam · Examination of Repairs
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6488002
31 May 2017
COI Inspection · Deficiency Check · Examination of Repairs
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6156156
20 July 2016
Annual Inspection · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5944612
2 July 2012
DAPI Audit · Administrative Inspection · COI Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4356614
23 August 2011
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4120465
6 October 2008
Hull Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3336369
20 May 2008
Administrative Inspection · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3208209
23 May 2007
Deficiency Check · In-Service Inspection · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2938219
4 May 2007
Examination of Repairs · COI Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2916966
4 May 2005
Annual Inspection
Physical examination · MIDET EAST BANK DETAIL · USCG Heartland District (CGD-H) · Activity 2348414
8 October 2004
Hull Examination
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 2216437
22 April 2004
Annual Inspection
Physical examination · MIDET WEST DETAIL · USCG Heartland District (CGD-H) · Activity 2050139
24 December 2002
COI Inspection
Physical examination · MIDET WEST DETAIL · USCG Heartland District (CGD-H) · Activity 1721243
13 December 2001
Annual Inspection
Physical examination · MIDET WEST DETAIL · USCG Heartland District (CGD-H) · Activity 1473977
7 December 1999
Initial Construction-Excluding Oversight · Initial Certification · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1397313
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 21 July 2020
Resolved
VHF Radio didn't display GPS position and didn't have the MMSI programmed in.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 August 2020
Resolved 20 August 2020
Resolution: Radio replaced with one that had built in GPS and the MMSI was programmed in.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 21 July 2020
Resolved
D/C electrical wiring was missing captive ends at screw type terminal blocks.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 August 2020
Resolved 20 August 2020
Resolution: All the D/C electrical wiring ends were replaced with captive type connectors.
07 - Fire Safety › N/A - No Subsystem › Inert gas system
Issued 21 July 2020
Resolved
CO2 storage cylinder was not elevated at least 2 inches above the deck.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 August 2020
Resolved 20 August 2020
Resolution: Bottle lifted up by Hiller technician.
07 - Fire Safety › N/A - No Subsystem › Inert gas system
Issued 21 July 2020
Resolved
The CO2 system piping branch line was missing the 2 inch stub end after the last nozzle.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 August 2020
Resolved 20 August 2020
Resolution: Stub end installed by Hiller technician.
09 - Working and Living Conditions › 091 - Living Conditions › Sanitary Facilities
Issued 21 July 2020
Resolved
The incinerator toilet wasn't mounted to the deck or connected to the exhaust piping.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 August 2020
Resolved 20 August 2020
Resolution: Toilet was re-installed correctly.
05 - Radio Communications › N/A - No Subsystem › Functional requirements
Issued 21 July 2020
Resolved
Vessel couldn't receive radio transmissions.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 August 2020
Resolved 20 August 2020
Resolution: New VHF-DSC radio installed and tested sat.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 21 July 2020
Resolved
Vessel's horn was inoperable.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 August 2020
Resolved 20 August 2020
Resolution: Horn was fixed.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 21 July 2020
Resolved
Fire pump didn't have remote means of operation at the helm.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 August 2020
Resolved 20 August 2020
Resolution: PTO pump on stbd MDE decommissioned from fire fighting use, satisfactory fire buckets now onboard.
Construction/Loadline › Hull › Longitudinal Frame
Issued 31 May 2017
Resolved
Observed crack in starboard side engine outboard mount. Repair to be performed as per CG approved repair plan. Repair to be verified by attending marine inspector prior to sailing of vessel.
Condition: Damaged By Earlier Event
Action required: 60 - Rectify deficiencies prior to movement
Due 31 May 2017
Resolved 29 June 2017
Resolution: Satisfactory inspection of repairs, dye-penterent NDT testing conducted.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 20 July 2016
Resolved
Failure to make vessel available for annual inspection. Last annual inspection was conducted on 23DEC14. 2015 Annual inspection was not conducted.
Condition: Invalid
Action required: 705 - Other - as specified
Due 20 July 2016
Resolved 20 July 2016
Resolution: Issued vessel NOV for missing annual inspection and counciled vessel rep the importance to schedule annual within the required 6 month window.
Construction/Loadline › Hull › Hull Plating
Issued 20 July 2016
Resolved
Identified approximately a 2" crack in the port bow 2 feet above the waterline. Find extent of crack and repair accordingly.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 27 July 2016
Resolved 25 July 2016
Resolution: Witnessed satisfactory repair of the crack. Crack was drill stopped, gouged, and rewelded.
Communications › Alarms/Indicators › Speed/Distance Indicator
Issued 21 May 2007
Resolved
Install required engine RPM gauges at operating station as per 46CFR182.410(b).
Due 23 June 2007
Resolved 11 June 2007
Engineering › Fuel Oil Storage/Transfer System
Issued 13 December 2001
Resolved
MAKE PROPER REPAIRS TO FUEL PIPING ON PORT SIDE. VESSEL NOT TO OPERATE UNTIL DEFICIENCY IS CLEARED BY ATTENDING MARINE INSPECTOR. LEGACY COMPONENT DESC: Piping
Condition: Improper/Lack of Maintenance
Due 14 December 2001
Resolved 14 December 2001
Engineering › Bilge Water Management System
Issued 13 December 2001
Resolved
REPAIR BILGE ALARMS IN ACCORDANCE WITH 46 CFR 182.530. LEGACY COMPONENT DESC: Piping
Condition: Improper/Lack of Maintenance
Due 14 December 2001
Resolved 14 December 2001
Resolution: ITEM CLEARED.