Records from 1983 to 2019. Most recent: inspection, 20 May 2019.
Inspection history · 23
20 May 2019
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6690510
6 February 2019
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6621058
3 May 2018
Administrative Inspection · Annual Inspection · Examination of Repairs
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6404232
16 February 2017
Periodic Inspection · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6089770
30 January 2017
Administrative Inspection · Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6079854
6 May 2016
Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5873310
9 January 2012
Drydock Exam · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4221840
1 October 2008
Administrative Inspection · Hull Examination · Internal Structural Exam · Deficiency Check · Examination of Repairs · COI Inspection · Drydock Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3340616
20 March 2007
Administrative Inspection · Uninspected Other
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2891284
30 March 2005
Uninspected Other
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2323090
3 June 2001
Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 198265
3 June 2001
Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 766285
24 February 1999
Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 730242
12 January 1999
Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 53728
9 November 1989
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1343679
18 May 1989
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1208261
17 February 1989
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1346784
23 November 1987
COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1312510
6 February 1987
Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1311269
14 November 1985
COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 996018
1 October 1985
Credit Drydock
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1297690
28 February 1985
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 980116
18 November 1983
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1279925
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 7 May 2018
Resolved
The Alcohol Testing strips onboard the vessel PIPER are expired. The vessel representatives were able to get new strips prior to USCG departure.
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 May 2018
Resolved 7 May 2018
Resolution: Vessel representative purchased new alcohol strips
Engineering › Diesel Engine (auxiliary) › Crankcase
Issued 3 May 2018
Resolved
The vessel PIPER had the port generator is leaking excessive oil out of the air intake and is a dangerous fire hazard. The starboard generator is inoperable. The installation of all systems of an engineering nature shall meet subchapter F.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 31 May 2018
Resolved 7 May 2018
Resolution: The vessel PIPER had crew and third party maintenance fix both generators. The port generator that was leaking; it was determined to be leaking because it was overfull.
Stability › Watertight Integrity › Watertight Subdivision Standard
Issued 3 May 2018
Resolved
The door in the machinery space did not have a proper watertight seal. The gasket was missing. The door is part of a watertight subdivision standard and should be watertight.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 1 June 2018
Resolved 7 May 2018
Resolution: All watertight gaskets were replaced; USCG inspectors conducted chalk test while on board for verification.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 3 May 2018
Resolved
The PIPER did not have suffecient emergency lighting in the machinery space and over the switchboard.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 June 2018
Resolved 7 May 2018
Resolution: The vessel installed additional required emergency lighting over the swithboard and looking towards the rudder room.
Communications › Radio Communications › EPIRB
Issued 16 February 2017
Resolved
EPIRB switch cover broken off and requires replacement.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 16 March 2017
Resolved 17 February 2017
Resolution: Plastic switch cover on EPIRB was replaced.
Electrical › Electric Supply System (service) › Cable
Issued 16 February 2017
Resolved
Extension cord and surge protector in printer area need removed.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 16 March 2017
Resolved 17 February 2017
Resolution: Extension cord and surge protector removed and replaced with a permanent electrical fixture.
Electrical › Electric Generation Source (service) › Generator
Issued 16 February 2017
Resolved
Starboard and port generators require covers over open holes on top side.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 16 March 2017
Resolved 17 February 2017
Resolution: Covers permanently installed on open holes in generators.
Electrical › Electric Generation Source (service) › Generator
Issued 16 February 2017
Resolved
Starboard generator requires protecting shroud to be installed.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 16 March 2017
Resolved 17 February 2017
Resolution: Protecting shroud was installed.
Fire Fighting › Fixed Fire Detection System › Control Panel
Issued 16 February 2017
Resolved
Fire control panel improperly indicating heat detection over starboard generator. Control panel must be either repaired or replaced.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 16 March 2017
Resolved 17 February 2017
Resolution: Control panel was fixed to fuction properly. Heat detectors were tested to ensure panel alarmed properly.
Engineering › Steering Gear System › Rudder Angle Indicator
Issued 16 February 2017
Resolved
Rudder indicator line on the port side rudder requires junction box installed at the splice (which was covered using a caulking tube).
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 16 March 2017
Resolved 17 February 2017
Resolution: Junction box was installed at the cable splice.