Records from 2004 to 2026. Most recent: inspection, 16 March 2026.
Inspection history · 31
16 March 2026
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8314638
30 April 2025
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 8126993
25 March 2024
COI Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7884855
27 September 2023
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7798878
22 June 2022
Drydock Exam · Annual Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7484391
27 September 2021
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7316709
13 April 2021
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7175076
11 December 2020
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7110165
16 September 2020
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7059036
21 June 2019
Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6720857
1 April 2019
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6653999
3 July 2018
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6472694
22 June 2018
Administrative Inspection · Hull Examination · Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6457608
4 October 2017
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6280388
28 June 2016
Administrative Inspection · Internal Structural Exam · Annual Inspection · Drydock Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5922492
31 May 2016
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5892560
22 September 2015
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5726112
14 October 2014
Type not recorded
No type recorded · Station Lake Charles · USCG Heartland District (CGD-H) · Activity 5005425
26 June 2014
Internal Structural Exam · Hull Examination · COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4900570
26 July 2012
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4391551
6 July 2012
Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4369685
3 August 2011
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4104523
17 September 2010
Ballast Water Examination · Deficiency Check · MTSA Verification · DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3851314
15 January 2009
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3388733
21 July 2008
Hull Examination · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3275869
16 July 2008
In-Service Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3270872
11 December 2007
Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3113608
25 October 2007
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3086654
21 July 2006
Deficiency Check · Hull Examination
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2720085
17 August 2004
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2168886
15 July 2004
Initial Construction-Excluding Oversight · Hull Examination · Initial Certification
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2134557
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 3 April 2024
Resolved
Each lifejacket must be marked with type I retro-reflective material approved under approval series 164.018. The arrangement of the retro-reflective material must meet IMO Resolution A.658(16).
Observed inadequate retro-reflective tape on 10 lifejackets.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 3 April 2024
Resolved 3 April 2024
Resolution: New retroreflective tape placed on lifejackets.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 3 April 2024
Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment and electrical shock.
Observed daisy chain electrical arrangement on bridge and bedding stored under the forward operating station containing electrical equipment.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 3 April 2024
Resolved 3 April 2024
Resolution: Daisy chain and bedding were removed from console.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 3 April 2024
Resolved
At each inspection for certification and every other vessel inspection all observed unsafe practices must be corrected.
Observed loose deck plates near port generator.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 3 April 2024
Resolved 3 April 2024
Resolution: Deck plate was secured.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 3 April 2024
Resolved
A hinged watertight bulkhead door must be fitted with a quick action closing devise operable from both sides of the door.
Dogs on galley watertight door were loose when closed.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 3 April 2024
Resolved 3 April 2024
Resolution: Dogs on watertight door were tightened and secured.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 3 April 2024
Resolved
No excessive accumulation of oil, debris, or other matter in the bilges and other spaces that might clog the bilge pumping system.
Observed excessive standing water in machinery space near port side air receiver.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 3 April 2024
Resolved 3 April 2024
Resolution: Standing water was vacuumed and disposed of.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 3 April 2024
Resolved
Electrical equipment on a vessel must be installed and maintained to provide services necessary for safety under normal and emergency conditions, protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock, minimize accidental personnel contact with energized parts, and prevent electrical ingnition of flammable vapors.
Observed cracked covers for lights in engine room.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 May 2024
Resolved 11 April 2024
Resolution: Rep provided evidence of new covers for lights.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 July 2022
Resolved
A vessel must be provided with a main steering gear that is: An independent rudder angle indicator at the operating station. Stbd rudder on both stations were inoperable. 46CFR182.610(f)(2)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 July 2022
Resolution: Vessel rep provided videographic evidence of operable stbd rudder angle on both stations.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 6 July 2022
Resolved
Individual cable wires must be enclosed and protected against weather in a non-hazardous location. Dead end wires were exposed on the main deck. 46CFR183.340
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 August 2022
Resolved 6 July 2022
Resolution: Vessel rep provided photographic evidence of dead end wires removed from the main deck.
09 - Working and Living Conditions › 092 - Working Conditions › Ventilation (Working spaces)
Issued 27 September 2021
Resolved
A space containing diesel machinery must be fitted with at least two ducts to furnish natural or powered supply and exhaust ventilation. The starboard generator room exhaust blower filter was soiled with oil and a cup placed under the opening to catch dripping oil from the filter.
46 CFR 182.465(c)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 October 2021
Resolved 28 September 2021
Resolution: Blower fan cleaned and operating properly.
09 - Working and Living Conditions › 092 - Working Conditions › Obstruction/slipping, etc.
Issued 27 September 2021
Resolved
A bilge pipe piercing the collision bulkhead must be fitted with a screw-down valve located on the forward side of the collision bulkhead and operable from the weather deck. The reach rod handle, located on deck, was obstructed by the forward anchor and was unable to be used unless the anchor was removed from it's stored location. This took approximately 5 minutes.
46 CFR 182.510(d)
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 October 2021
Resolved 28 September 2021
Resolution: Anchor storage was moved and no longer obstructing the reach rod.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 27 September 2021
Resolved
Each hose must be lined commercial fire hose that conforms to UL 19 or hose that is listed and labeled by an independent laboratory recognized by the Commandant as being equivalent in performance. The Port Forward fire hose has a pinhole leak around the middle of the hose. The damaged hose was replaced with a new approved hose.
46 CFR 181.320(b)(1)
Condition: Damaged By Earlier Event
Action required: 10 - Deficiency Rectified
Resolved 27 September 2021
Resolution: Damaged hose was replaced with a new approved hose.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 16 September 2020
Resolved
Starboard emergency escape hatch had a broken handle.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 September 2020
Resolution: Handle replaced.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 16 September 2020
Resolved
Watertight doors were loose allowing airflow from galley into machine space, and from machine space into engine room.
Action required: 10 - Deficiency Rectified
Resolved 16 September 2020
Resolution: Operator corrected by tightening dogs on the door down.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 16 September 2020
Resolved
Retroflective tape on all three life ring buoys onboard were worn or tearing and ineffective.
Action required: 10 - Deficiency Rectified
Resolved 16 September 2020
Resolution: New retroreflective tape applied to the life ring buoys onboard.
Lifesaving › Lifefloat › Quantity
Issued 1 July 2016
Resolved
Original COI lists 4 life floats carrying 78 persons. Vessel currently has 5 life floats for 80 personnel. Vessel is waiting for original 22 person life float to be in compliance. Reduced carriage to 68 personnel.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 August 2016
Resolved 5 July 2016
Resolution: Removed one 12 person life float, replaced with one 22 person life float to comply with COI.
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 22 September 2015
Resolved
Failed smoke detector in galley passage way.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 September 2015
Resolved 23 September 2015
Resolution: Vessel rep provided proper operation of smoke detector.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 22 September 2015
Resolved
Mast Light extinguished.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 September 2015
Resolved 23 September 2015
Resolution: mast light plug was replaced, tested ALL SAT.
Navigation › Piloting/Steering › Marine Charts
Issued 26 June 2014
Resolved
Vessel did not have local Amelia chart.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 July 2014
Engineering › Lubricating Oil Storage/Transfer System › Tank
Issued 26 June 2014
Resolved
Sight glass on tank was plastic instead of glass.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 July 2014
Documentation › Certificates/Documents › Stability Letter
Issued 26 July 2012
Resolved
Vessel does not meet new AAWPP standards as per MSIB 001-11
Action required: 705 - Other - as specified
Resolved 26 July 2012
Engineering › Generator (propulsion/auxiliary-electric) › Circuit Breaker (overload/over current protection)
Issued 17 September 2010
Resolved
Service both generators to prove proper operation of overspeed tests. Provide 3rd party cert attesting sat overspeeed tests.
Action required: 17 - Rectify deficiencies prior to departure
Due 17 October 2010
Resolved 18 September 2010
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 17 September 2010
Resolved
Replace burnt out e-light in passenger compartment leading to main deck.
Action required: 17 - Rectify deficiencies prior to departure
Due 17 October 2010
Resolved 18 September 2010
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 15 January 2009
Resolved
Lower Not Under Command light not operational. Bulb needs replacement.
Condition: Unknown
Due 16 January 2009
Resolved 15 January 2009
Lifesaving › Lifefloat › Float Free
Issued 16 July 2008
Resolved
Remove cover over lifefloats to allow for float free operation.
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Due 16 July 2008
Resolved 16 July 2008
Resolution: Captain and crew removed cover and removed from service
Fire Fighting › Means of Escape › Escape Route Signs
Issued 25 October 2007
Resolved
Mark all doors leading into spaces that are protected by CO2
Due 25 November 2007
Resolved 11 December 2007
Lifesaving › Lifefloat › Not on Board
Issued 25 October 2007
Resolved
Replace spacers between life floats.
Due 25 November 2007
Resolved 11 December 2007
Personnel › Certificates/Documents/Licenses › License, Radio Officer
Issued 25 October 2007
Resolved
Master [name withheld], has Restricted Marine Operators FCC permit. Must have the unrestricted Marine Operators Permit
Due 25 November 2007
Resolved 11 December 2007
Communications › Alarms/Indicators › General Alarm
Issued 25 October 2007
Resolved
Renew aft deck GA speaker to proper volume.
Due 25 November 2007
Resolved 11 December 2007
Documentation › Certificates/Documents › FCC SSL
Issued 25 October 2007
Resolved
Provide marine inspector with correct vessel FCC call sign.
Due 25 November 2007
Resolved 11 December 2007
Fire Fighting › Fixed Fire Detection System › Approval
Issued 15 July 2004
Resolved
Provide approved fire detection system plans.
Action required: 705 - Other - as specified
Due 21 August 2004
Resolved 17 August 2004
Resolution: Provided.