ELISE MARY

ELISE MARY is a 2008 offshore supply vessel. The Coast Guard has recorded 23 inspections since 2016, most recently in February 2026, along with 69 deficiencies — 1 with no resolution recorded — and 3 casualty investigations between 2014 and 2022.

Records from 2014 to 2026. Most recent: inspection, 5 February 2026.

Built
2008
Last inspected
5 February 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Everything above is free. The detail below — the inspection history, the deficiency record, the tow units, the casualty record and the documentation record — is Professional, $39 a month. Sign in.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 2016.

Inspection record

Last inspected 5 February 2026
…with no type recorded3
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9547647
WDH3919
862658
Flag
UNITED STATES
Maury page id
psix-862658

Documentation record

Registered dimensions (L × B × D)151.4 ft × 40.0 ft × 13.0 ft
Registered tonnagegross 99 / net 67
ITC dimensions (L × B × D)151.4 ft × 40.0 ft × 13.0 ft
ITC tonnagegross 623 / net 186
BuilderA & B INDUSTRIES OF MORGAN CITY INC · AMELIA, LA, UNITED STATES · built 2008
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portLOCKPORT, LA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 4 February 2026 · expires 28 February 2027
Service, as the file records itOffshore Supply Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it623 - Convention (Subpart B), Gross Ton
99 - Regulatory (Subpart C or D), Gross Ton
186 - Convention (Subpart B), Net Ton
67 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
Detail on this page

23 inspections, each with its date, unit and type; 69 deficiencies with the resolution recorded against each; 8 vessels inspected with it, by name and date; 3 casualty investigations, with date and classification; the documentation record: dimensions, tonnage, builder, hailing port, endorsements, dates. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 8

Inspection history · 23

5 February 2026 Deficiency Check · Administrative Inspection · Periodic Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8277581
8 December 2025 Cargo Tank Internal · Administrative Inspection · Internal Structural Exam · Drydock Exam · In-Service Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8267727
13 February 2025 Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8079398
8 January 2024 Deficiency Check
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 7847324
20 December 2023 COI Inspection · Deficiency Check
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 7840121
9 November 2023 Drydock Exam · Internal Structural Exam · Cargo Tank Internal · MTSA Verification · Deficiency Check · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7822452
26 January 2023 Annual Inspection
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 7616855
26 January 2023 Deficiency Check
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 7631255
1 June 2022 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7803904
9 February 2022 Deficiency Check
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 7393493
8 February 2022 Annual Inspection
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 7392967
13 April 2021 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7175076
9 December 2020 Cargo Tank Internal · Annual Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7108963
17 February 2020 Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 6916441
13 February 2020 Annual Inspection · MTSA Verification · Administrative Inspection
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 6916359
6 June 2019 Damage Survey · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6706061
26 February 2019 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6632835
20 November 2018 Internal Structural Exam · Administrative Inspection · Hull Examination · COI Inspection · Cargo Tank Internal · Drydock Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6584022
2 February 2018 Type not recorded
No type recorded · USCGC SAILFISH (WPB 87356) · USCG Northeast District (CGD-NE) · Activity 6351994
10 January 2018 Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6335355
3 January 2017 Deficiency Check · Administrative Inspection · Periodic Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6065355
8 December 2016 Administrative Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6054775
3 February 2016 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5808604

Deficiency record · 69

03 - Water/Weathertight Conditions › N/A - No Subsystem › Cargo & other hatchways
Issued 5 February 2026 Resolved
Each hatch exposed to the weather must be watertight. Back deck escape hatch had a pinhole in the escape trunk. Vessel rep cut out section and rewelded with new metal corrected on the spot.
Action required: 10 - Deficiency Rectified
Due 5 February 2026
Resolved 5 February 2026
Resolution: Vessel rep cut out section and rewelded with new metal corrected on the spot.
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 13 February 2025 Resolved
Each OSV must carry at least one rescue boat. In lieu of a rescue boat, an OSV may serve as its own rescue platform using alternative equipment if they prove to the OCMI that they are able to recover a helpless person from the water. The vessel had a rescue platform onboard but declined to show the Coast Guard how to recover a rescue manikin from the water under existing weather conditions; in addition, the vessel safety coordinator requested time to train and practice before the demonstration to the Coast Guard. Vessel must demonstrate to a CG inspector proficiency in recovering a weighted dummy from the water to demonstrate compliance w/ CG regs.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 March 2025
Resolved 7 March 2025
Resolution: Vessel conducted additional training and drills with a focus on lifting unconscious person. Documentation of drills and training was provided to Inspection team. Crew will demonstrate proficiency for CG inspectors at next inspection.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 13 February 2025 Resolved
Panelboard switching units must have a circuit directory card with circuits designations, description of load and rating/setting of over-current protective device for each circuit. Circuit panelboard in machinery spaces was missing required directory card.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 March 2025
Resolved 13 February 2025
Resolution: Vessel rewrote and replaced directory card.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 20 December 2023 Resolved
For each 79,500 L (21,000 U.S. gallons) or part thereof of any Class 3 (flammable) or combustible liquid being transported on board a vessel in a portable tank there must be provided a fire hose fitted with an approved portable mechanical foam nozzle. Vessel's foam nozzle would not secure water flow when closed. Vessel to replace or repair. 49 CFR 176.315
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 8 January 2024
Resolution: New Vari nozzle was provided.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 20 December 2023 No resolution recorded
The means to stop the flow may be a pump control, a quick-acting, power actuated valve, or an operating procedure. If an emergency pump control is used, it must stop the flow of oil or hazardous material if the oil or hazardous material could siphon through the stopped pump. Forward port and sbd liquid mud tank air actuated valves were inoperable. Operation valves to be witnessed by marine inspector prior to carrying liquid mud. 46 CFR 131.935(b) and 33 CFR 155.780(b)
Action required: 701 - Prior to carriage of passengers/cargo
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 20 December 2023 Resolved
The vessel owner or operator must establish in the approved VSP the frequency of application of any security measures for access control, particularly if these security measures are applied on a random or occasional basis. Baggage screenings were not being conducted as per VSP. 33 CFR 104.265(d)(2)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 8 January 2024
Resolution: Screenings are being completed.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 20 December 2023 Resolved
The following matters must be entered in each vessel's logbook: Tests and inspection of Steering Gear, Whistle, and Means of Communication. Before departure. Draft and Loadline Markings. Before leaving port. Verification of Compliance with Applicable Stability Requirements. Tests of Emergency Lighting and Power. Weekly, monthly, and twice-yearly. Periodic Sanitary Inspections. *CORRECTED*
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 21 December 2023
Resolution: Vessel Provided a document showing required log entries were completed.
01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 20 December 2023 Resolved
The vessel owner or operator must ensure all restricted areas are clearly mark and indicate that access to the area is restricted and that unauthorized presence within the area constitutes a breach of security. Vessel recently left dry dock and needed to replace missing placards on exterior doors leading to pilothouse.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 8 January 2024
Resolution: Placarding was renewed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 9 November 2023 Resolved
Vessel shall be in a safe and seaworthy condition. Vessel's STBD MDE had a fuel leak on the port side near a high pressure fuel line.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 December 2023
Resolution: Received service ticket from Third Party Vendor stating issue corrected.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 9 November 2023 Resolved
Valves for removing water or impurities from fuel oil systems will be permitted in the machinery space provided such valves are fitted with caps or plugs to prevent leakage. Multiple RACOR sets were leaking fuel oil into a catch pan or onto the deck.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 December 2023
Resolution: MI verified no leaks on RACOR.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 9 November 2023 Resolved
Electrical equipment on a vessel must be designed, installed, and maintained to protect crew, offshore workers and vessel from electrical hazards. Vessel has an active 2 amp ground verified when switching generators.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 December 2023
Resolution: Vessel Rep provided Third Party [name withheld] stating ground fault corrected.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 9 November 2023 Resolved
Electrical equipment used in the following spaces must be drip-proof. Vessel has an electrical panel in the ER with bungie cord strapped to attempt to keep it closed.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 December 2023
Resolution: Vessel had installed new bolt to secure panel.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 9 November 2023 Resolved
Electrical equipment on a vessel must be designed, installed, and maintained to protect crew, offshore workers and vessel from electrical hazards. Vessel had unknown liquid in one of the battery boxes and multiple boxes where the lid would not properly cover the box to prevent liquid going inside the battery box.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 December 2023
Resolution: Battery boxes were dried up and fitted with proper covers.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 9 November 2023 Resolved
Electrical equipment on a vessel must be designed, installed, and maintained to protect crew, offshore workers and vessel from electrical hazards. The dryer's electrical outlet is being pulled away from the wall with dryer vent and lint accumulation nearby.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 December 2023
Resolution: Dryer's outlet was properly secured to the wall.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 9 November 2023 Resolved
Vessel shall maintain watertight integrity. Light was observed through the emergency escape hatch when fully closed.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 December 2023
Resolution: Signed [name withheld] is objective evidence that vessel has resolved issue.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 9 November 2023 Resolved
Vessel shall maintain watertight integrity. Air was felt flowing through the ER WTD while fully dogged from the escape hatch. Top left dog did not fully connect to the striker plate. The QAWTD or door gasket may be warped near the bottom forward area.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 December 2023
Resolution: Signed [name withheld] is objective evidence that vessel has resolved issue.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 9 November 2023 Resolved
Each vessel must have permanently installed and efficient guard rails on decks or bridges. On top of the bridge near the ER air intakes and the rear light, the vessel had multiple rails that were wasted.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 December 2023
Resolution: Bad sections of the railing were cropped and renewed with new material.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for radio personnel
Issued 9 November 2023 Resolved
Each vessel must comply with 47CFR Part 80 as applicable. Both Licensed Officer (Master or Mate) did not have a Marine Radio Operator Permit.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 December 2023
Resolution: Master provided a valid marine operator permit.
10 - Safety of Navigation › N/A - No Subsystem › Rudder angle indicator
Issued 9 November 2023 Resolved
Rudder angle indicator independent of the control must be installed at the steering control station. Vessel had >10 degree deflection for both port and stbd rudders and the rear steering control station rudder angle indicator did not function.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 December 2023
Resolution: Vessel rep provided Third Party service ticket stating issue is corrected.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 9 November 2023 Resolved
Lifebuoys must be distributed as to be readily available on each side of the OSV, on each open deck, and one must be located near the stern. One of the required lifebuoys was not installed near the stern.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 December 2023
Resolution: Lifebuoy was installed on stern railing.
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 9 November 2023 Resolved
Suitable hand covers, guards, or rails must be installed on each exposed and dangerous space including hot surfaces. The Port MDE exhaust lagging had fallen down exposing a two foot length of exhaust pipe.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 December 2023
Resolution: Exposed sections of the portside MDE exhaust pipe was properly protected lagging.
04 - Emergency Systems › N/A - No Subsystem › Emergency steering position com./ compass reading
Issued 9 November 2023 Resolved
Each vessel must have a main and independent auxiliary means of steering. Vessel's auxiliary steering was not functional, one of the two steering pumps would not operate, and the mate did not know how to transfer the steering.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 December 2023
Resolution: Steering was tested on both pumps including auxiliary steering station. All tested satisfactory.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 9 November 2023 Resolved
Vessel shall be in a safe and seaworthy condition. Vessel's STBD MDE has a diagnostic code for engine oil filter pressure differentiation.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 December 2023
Resolved 14 December 2023
Resolution: Vessel rep provided Third Party service ticket stating issue corrected.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 9 November 2023 Resolved
An abandon-ship drill must be held on each vessel in alternate weeks. Vessel was rotating one drill per week between fire, abandon-ship and MOB and not completing drill on alternate weeks.
Action required: 10 - Deficiency Rectified
Resolved 9 November 2023
Resolution: Educated crew and company personnel
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 9 November 2023 Resolved
An fire drill must be held on each vessel in alternate weeks. Vessel was rotating one drill per week between fire, abandon-ship and MOB and not completing drill on alternate weeks.
Action required: 10 - Deficiency Rectified
Resolved 9 November 2023
Resolution: Educated crew and company personnel.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 26 January 2023 Resolved
Suitable hand covers, guards, or rails must be installed on each exposed and dangerous place, such as gears of rotating machinery. Port shaft deck plate was loose. 46 CFR 127.330
Action required: 60 - Rectify deficiencies prior to movement
Resolved 26 January 2023
Resolution: Deck plate was secured.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 26 January 2023 Resolved
A vessel of less than 100 gross tons must have adequate emergency lighting fitted along the line of escape to the main deck from accommodations and working (machinery) spaces below the main deck. Engine room escape trunk and alley way ladder well lights were weak. 46 CFR 129.440(a)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 26 January 2023
Resolution: Emergency lights were repaired.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 26 January 2023 Resolved
Where pressure-indicating gages are used the size of the visual display, the fineness of graduations, and the orientation of the display will be considered. In no case shall the upper range of the gage be less than 1.2 times nor more than 2 times the pressure at which the relieving device is set to function. Both pressure vessels had a relief valve set at 175psi with tank gauges 0-200 psi. Gauges required to be at least 210 psi. 46 CFR 54-15-5(f)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 20 March 2023
Resolution: Gauges replaced with correct range.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 26 January 2023 Resolved
Each Class 1 door must have a quick action closing device operative from both sides of the door. Aft pilothouse storage locker was outfitted with a class 1 door, but did not have a handwheel on the closing device. 46 CFR 127.230(a) 46 CFR 170.270(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 20 March 2023
Resolution: Handwheel replaced
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 26 January 2023 Resolved
The fire-main system must be operated, and the pressure checked at the remotest and highest outlets. Each fire hose must be subjected to a test pressure, equivalent either to the maximal pressure to which it may be subjected in service or to 690 kPa (100 psi), whichever is greater. Fire hose tests found one hose holed and leaking water. 46 CFR 132.350 (c)(3)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 20 March 2023
Resolution: Fire hose replaced.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 26 January 2023 Resolved
The following must be carried out and logged. Periodic sanitary inspections, weekly emergency lighting tests,and steering gear/whistle/means of communication 12 hours before departure if away from shore for 48 hours. Once a week if away for less than 48 hours. 46 CFR 131.515(b) 46 CFR 131.525(a) 46 CFR 13.505(a) or (b)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 20 March 2023
Resolution: Log entries made.
08 - Alarms › N/A - No Subsystem › General alarm
Issued 26 January 2023 Resolved
Each general alarm bell must be identified by red letters at least 13 millimeters ( 1/2-inch) high that state the following: “GENERAL ALARM - WHEN BELL RINGS GO TO YOUR STATION.” Placards were missing in engine room and crew accommodation deck. 46 CFR 131.810
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 20 March 2023
Resolution: Placards were installed.
07 - Fire Safety › N/A - No Subsystem › Fire control plan
Issued 26 January 2023 Resolved
Each vessel must have a permanently exhibited, for the guidance of the master and crew members, general arrangement plans showing, for each deck, various vessel fire fighting systems. Plan located in galley seating area was faded and unable to read. 46 CFR 131.945
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 20 March 2023
Resolution: Plan was made legible.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 26 January 2023 Resolved
The means to stop the flow may be a pump control, a quick-acting, power actuated valve, or an operating procedure. If an emergency pump control is used, it must stop the flow of oil or hazardous material if the oil or hazardous material could siphon through the stopped pump. Port and Stbd liquid mud tank air actuated valves require operational testing. One of vessel's two PTOs was also inoperable. Marine inspector to witness satisfactory operation of pumps and valves prior to carrying liquid mud. 46 CFR 131.935(b) and 33 CFR 155.780(b)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 December 2023
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 8 February 2022 Resolved
The inspection for certification is made by a marine inspector to determine whether the vessel is in a safe and seaworthy condition…The scope of the annual inspection is the same as the inspection for certification as specified in 126.430, but in less detail unless the cognizant marine inspector deficiencies. The vessels fire main pump had excessive leaking into the pump compartment to include excessive spraying onto electrical equipment unprotected from this hazard. 46CFR126.520(a)(1)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 March 2022
Resolved 16 February 2022
Resolution: Vessel replaced fire pump to the satisfaction of the MI.
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 8 February 2022 Resolved
Piping subject to internal head pressure from oil in the tank must be fitted with positive shutoff valves located at the tank. Valves installed on the outside of the oil tanks must be…arranged with a means of manual control locally at the valve and remotely from a readily accessible and safe location outside of the compartment in which the valves are located. The remote fuel shut off valves could not be satisfactorily operated at time of inspection. Vessel shall ensure crew is familiar with remote system and ensure remote valves are operational at all times. 46CFR56.50-60
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 February 2022
Resolution: Valves were misaligned during test. Crew was trained on proper alignment by port capt and tested satisfactory.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 8 February 2022 Resolved
Each OSV must have, at the pilothouse, controls to start a fire pump, charge the fire main, and monitor the pressure in the fire main. The vessel keeps the sea valve to the fire main closed at all times, thus preventing the fire main from charging after starting the system from the pilothouse. Vessel shall ensure necessary valves are open to allow the system to properly charge from the remote start location. 46CFR130.430
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 February 2022
Resolution: Valves to provide fire fighting water to fire pump were opened.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 8 February 2022 Resolved
The inspection for certification is made by a marine inspector to determine whether the vessel is in a safe and seaworthy condition…The scope of the annual inspection is the same as the inspection for certification as specified in 126.430, but in less detail unless the cognizant marine inspector deficiencies. Vessel had excessive oil accumulation in the tunnel/bow thruster tunnel space and the fuel system control space located forward of the engine room. Vessel shall ensure bilge spaces are kept free of oil accumulation. 46CFR126.520(a)(1)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 February 2022
Resolution: Oily bilge water was pumped to vessel's holding tanks to be transferred to on shore facility for disposal.
02 - Structural Conditions › N/A - No Subsystem › Loading/Ballast condition
Issued 8 February 2022 Resolved
The following matters must be entered in each vessel's logbook: Verification of Compliance with Applicable Stability Requirements. Vessel was not verifying and logging that the onboard cargo was in compliance with the stability letter and loading diagram. Vessel must verify stability for cargo and log entries into the log book during all future voyages. 46CFR131.620(d)
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 February 2022
Resolution: Stability verification now logged.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 8 February 2022 Resolved
Each survival craft must be approved and equipped as follows: Each lifefloat must be approved under approval series 160.027 and be equipped with one painter, the painter must have a float-free link meeting the requirements of part 160, subpart 160.073 of this chapter, connecting the painter to the OSV. Vessels float free link for the lower lifefloat was broken. Vessel must replace float free link. Vessels carriage of offshore workers is reduced by 12 until corrected. 46CFR133.105(a)(4)(iii)(E)
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 9 February 2022
Resolution: Weak link for lower life float replaced.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 8 February 2022 Resolved
This section applies to each vessel with watertight doors in bulkheads made watertight in compliance with this chapter. A Class-1 door may be installed at any place if the door has a quick-acting closing-device operative from both sides of the door. The class 1 door at the aft superstructure and engine compartment emergency escape trunk would not sufficiently close to all for a weathertight seal. Vessel shall make necessary adjustment to ensure proper operation of each door. 46CFR174.210(e)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 February 2022
Resolved 9 February 2022
Resolution: QAWTDs were adjusted and verified watertight by ABS Surveyor.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 8 February 2022 Resolved
Nonmetallic flexible hose must be in accordance with SAE J1942 (incorporated by reference; see 46 CFR 56.01-2) and may be installed only in vital and nonvital fresh and salt water systems, non-vital pneumatic systems, lube oil and fuel systems, and fluid power systems. Both pneumatic systems (pressure vessels) used for vital systems as described in 46CFR128.130 had nonmetallic flexible hose installed on the supply lines approximately 12 inches downline from the tank. The flexible hoses on the port pressure vessel had a large bulge and was leaking air. Vessel shall replace nonmetallic flexible hose with approved. 46 CFR 56.60-25(b)(1)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 15 February 2022
Resolution: Flex hose was replaced with metallic piping.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 8 February 2022 Resolved
Except in an emergency, no repairs or alterations to the hull or machinery, or to equipment that affects the safety of the OSV, may be made without notice to the cognizant OCMI in the inspection zone where the repairs or alterations are to be made. When the repairs or alterations have been made, notice must be given to the OCMI as soon as practicable. Vessel replaced the main deck coaming and hatch to the engine compartment emergency escape trunk. No notice to the local OCMI was given. Vessel shall provide evidence of satisfactory non-dustructive testing results. 46CFR131.565(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 15 February 2022
Resolution: Non destructive testing was completed on hatch and found satisfactory.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 8 February 2022 Resolved
Each Emergency Position Indicating Radio Beacon (EPIRB) and each Search and Rescue Transponder (SART), other than an EPIRB or SART in an inflatable liferaft, must be tested monthly. The EPIRB must be tested using the integrated test circuit and the output indicator (test button) to determine that it works. Vessel was not conducting monthly test of EPIRB and entering in the vessel's logbook. 46CFR131.565(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 9 February 2022
Resolution: Vessel provided objective evidence that EPIRB checked was on monthly check sheet and completed crew training on sheet.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 14 December 2020 Resolved
Vessel shall have the safety relief valves settings for all safety or relief valves for all pressure vessels. Vessel did not have any paperwork for the safety or relief valves or tags stating when the testing was completed.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 January 2021
Resolved 21 December 2020
Resolution: Safety Relief Valves tested per Third Party report to the satisfaction of the MI.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 14 December 2020 Resolved
In no case shall the upper range of the gage for pressure vessels be less than 1.2 times nor more than 2 times the pressure at which the relieving device is set to function. The port gauge maximum pressure was 400 psi and the starboard was 200 psi with a MAWP of 175 psi.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 January 2021
Resolved 21 December 2020
Resolution: Vessel changed the P/S Pressure Gauges on the Pressure Vessels. Confirmed with Vessel Rep that both were changed out.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 14 December 2020 Resolved
The non-metallic fuel hoses must be maintained to prevent fire. The crankcase oil return hose on the port side of the port main engine was chaffed.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 January 2021
Resolved 21 December 2020
Resolution: Vessel changed out fuel hose and installed chaffing gear.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 14 December 2020 Resolved
Electrical installations on vessels must ensure the protection of passenger, crew, other persons and the vessel from electrical hazards. The waterheater wiring was hanging outside the control box and was exposed.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 January 2021
Resolved 21 December 2020
Resolution: Vessel had wiring for water heater covered.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 14 December 2020 Resolved
No means may be provided for locking any interior door giving access to either of the two required means of escape. The engine room door and engine room escape door were able to locked closed from the outside of the door.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 January 2021
Resolved 21 December 2020
Resolution: Vessel had cut off the exterior lock for the escape hatch.
11 - Life Saving Appliances › N/A - No Subsystem › Line-throwing appliance
Issued 13 February 2020 Resolved
Vessel was equipped with an auxiliary line that was not of appropriate length. Each OSV must have a line-throwing appliance that is approved under approval series 160.031 or 160.040. Vessel was equipped with an impulse rocket which is approved under 160.040. For an appliance approved under approval series 160.040, an auxiliary line of at least 450 meters (1,500 feet) long is required to be on board. Line must have a breaking strength of at least 40 kiloN ewtons (9,000 pounds-force); and if synthetic, a dark color or certified by the manufacturer to be resistant to deterioration from ultraviolet light. 46 CFR 133.170(c)(2)(i).
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 March 2020
Resolved 17 February 2020
Resolution: Auxiliary line of approx 10,000 lbs breaking strength and of 1500 ft long was purchased and placed onboard.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 June 2019 Resolved
Provide suitable replacement for sheared starboard tailshaft.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 June 2019
Resolution: Damaged tailshaft was replaced with new tailshaft. Blue fit test conducted to ensure proper fit.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 10 January 2018 Resolved
Replace the junction box for port embarkation light and clean lenses on port and starboard lights.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 12 January 2018
Resolved 12 January 2018
Resolution: J-box fixed and glass cleaned.
Navigation › Piloting/Steering › Compass Deviation Table
Issued 10 January 2018 Resolved
Obtain a current readable compass deviation table.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 January 2018
Resolved 12 January 2018
Resolution: Compass deviation table current.
Stability › Watertight Integrity › Watertight Subdivision Standard
Issued 10 January 2018 Resolved
Renew gaskets and prove proper operation of water tight doors in engine room and with engine room escape hatch.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 January 2018
Resolution: Old gaskets removed. metal preped and painted new gasket installed verifed by USCG MI.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 10 January 2018 Resolved
Emergency lights need new batteries.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 January 2018
Resolved 12 January 2018
Resolution: Batteries replaced. Proper operation verified by USCG MI
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 10 January 2018 Resolved
Batteries expired in water lights.
Condition: Invalid
Action required: 705 - Other - as specified
Due 17 January 2018
Resolved 12 January 2018
Resolution: Batteries replaced and verified by USCG MI.
Engineering › Fuel Oil Service System › Piping
Issued 10 January 2018 Resolved
Replace fuel oil hose on the starboard generator. Hose not of approved type.
Condition: Invalid
Action required: 705 - Other - as specified
Due 16 February 2018
Resolved 12 January 2018
Resolution: F/O hoses replaced.
Electrical › Electric Generation Source (service) › Ground Detection
Issued 10 January 2018 Resolved
Ground indicator on switchboard not operable.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 February 2018
Resolved 8 February 2018
Resolution: Attended vessel witnessed test of ground meter.
Navigation › Piloting/Steering › Marine Charts
Issued 3 January 2017 Resolved
Each vessel must carry adequate and up to date nautical charts of a scale appropriate for navigation. Vessel's charts are out of date.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 January 2017
Resolution: Vessel recieved new charts.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 3 January 2017 Resolved
Each vessel must carry adequate and up to date nautical publications for the intended voyage. Vessel's nautical publications are from 2014.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 January 2017
Resolution: Vessel got new pubs.
Lifesaving › Lifefloat › Float-free Link
Issued 3 January 2017 Resolved
Each OSV fitted with a life float must be fitted with a float-free link meeting 46CFR160.073. Vessel's float-free link has no label attesting to approval or capacity.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 January 2017
Resolution: Vessel replaced the float free weak links.
Lifesaving › Lifefloat › Markings
Issued 3 January 2017 Resolved
Each life float must be marked with the name of the vessel and the number of persons it is approved to carry. Life float markings are severly faded.
Due 10 January 2017
Resolved 6 January 2017
Resolution: Float's capacity were stenciled.
Lifesaving › Lifefloat › Paddle
Issued 3 January 2017 Resolved
Each paddle and oar must be marked with the name of the vessel. Life float paddles not marked.
Due 10 January 2017
Resolved 6 January 2017
Resolution: Paddles were stenciled with the vessel name.
Lifesaving › Lifefloat › Retroreflective Material
Issued 3 January 2017 Resolved
Each life float must meet the the design and approval standard of 46CFR160.017. Vessel's life float is not fitted with appropriate retrofeflective material.
Due 10 January 2017
Resolved 6 January 2017
Resolution: Reflective tape was replaced on the life floats.
Engineering › Steering Gear System › Rudder Angle Indicator
Issued 3 January 2017 Resolved
Each steering system on an OSV must be fitted with a rudder angle indicator. Vessel's RAI is not operating properly.
Due 10 January 2017
Resolved 6 January 2017
Resolution: 3rd party corrected the rudder angle indicators.
Accommodation/Occupational Safety › Refrigeration (stores) › General
Issued 3 January 2017 Resolved
Each cooking appliance must be installed so as to prevent movement in heavy weather. Secure refridgerator.
Due 10 January 2017
Resolved 6 January 2017
Resolution: Locking mechanism was added to the fridge.
Electrical › Electrical Distribution System (service) › Wiring
Issued 3 January 2017 Resolved
Each cable installation must meet IEC as applicable. Wire runs must be secure at intervals not exceeding 400mm on horizontal installations by metallic wire stays. Vessel missing multiple wire stays.
Due 10 January 2017
Resolved 6 January 2017
Resolution: Metal wire stays were added to the cables at required locations.
Fire Fighting › Fire Main › Valves
Issued 3 January 2017 Resolved
Each component of fire fighting equipment must be ready for use at all times. Fire main pressure relief valve is leaking past valve.
Due 10 January 2017
Resolved 6 January 2017
Resolution: Pressure relief valve was replaced.
Documentation › Logs/Records › Logbook (official)
Issued 3 February 2016 Resolved
Vessel did not log drills for the month of Nov 2015 and was logging drill every two weeks instead of every other week.
Action required: 705 - Other - as specified
Due 11 February 2016
Resolved 4 February 2016
Resolution: Vessel rep was educated and an abandon ship and fire drills were conducted staisfactory, notified vessel rep of next annual inspection that vessel drill log will be check for correctness.

Casualty record · 3

10 March 2014Routine · role: Involved in a Marine Casualty · activity 4815341
13 April 2021Major Marine Casualty · role: Transiting Vicinity of Primary Subject · serious marine incident, as classified · 13 dead · 1 injured · activity 7175076
1 June 2022Routine · role: Involved in a Marine Casualty · activity 7803904
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.