Documentation record
Registered dimensions (L × B × D)85.0 ft × 26.0 ft × 7.7 ft
Registered tonnagegross 186 / net 126
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderST LOUIS SHIPBUILDING & · ST LOUIS, MO, UNITED STATES · built 1958
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portDICKINSON, TX
Endorsements, as the file codes themcw_un
DocumentationCase Pending · issued 19 February 2025 · expires 28 February 2026
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it186 - Regulatory (Subpart C or D), Gross Ton
126 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 41
30 October 2023
Annual Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7816555
26 October 2022
Annual Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7584382
11 May 2022
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7452958
23 September 2021
Type not recorded
No type recorded · Station Freeport · USCG Heartland District (CGD-H) · Activity 7319359
22 September 2021
Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7318260
15 September 2020
Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 7060057
20 July 2020
Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7011364
13 July 2020
Initial Certification · Administrative Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6993853
29 August 2019
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6811093
9 March 2019
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6639200
9 March 2019
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6639211
4 May 2017
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6141413
13 April 2017
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6124675
21 June 2015
Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 5161913
1 February 2015
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5062632
12 June 2014
MTSA Verification · Industry Initiated Exam
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 4890127
14 February 2014
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 4800187
28 March 2012
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 4273883
16 November 2011
Marine Casualty Follow Up
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4189932
15 November 2011
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4189348
5 April 2011
Type not recorded
No type recorded · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3979371
21 December 2010
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3914487
11 December 2010
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3908805
3 October 2010
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3863711
28 September 2010
Deficiency Check · MTSA Verification · Industry Initiated Exam
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3858632
2 March 2010
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3688761
15 February 2010
Type not recorded
No type recorded · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 4059746
6 January 2009
Type not recorded
No type recorded · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3389499
5 January 2009
Administration
Administrative · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3389114
14 October 2007
Type not recorded
No type recorded · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3081806
4 September 2007
Deficiency Check
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 3048702
31 August 2007
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3043991
3 July 2007
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2982188
19 February 1998
Type not recorded
No type recorded · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 413010
14 January 1998
Type not recorded
No type recorded · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 411882
23 March 1996
Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 165824
30 August 1995
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 757761
29 August 1995
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 714140
25 August 1995
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 196049
25 August 1995
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 218875
20 June 1992
Type not recorded
No type recorded · MSO Paducah · USCG Heartland District (CGD-H) · Activity 138559
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 20 July 2020
Resolved
All owners and operators of an existing towing vessel must have a valid COI prior to the specified phase-in period. This vessel is one of the 67% of the vessels that has not obtained a valid COI. The vessel shall be made available for a Coast Guard COI inspection within 90 days. If an inspection is not completed prior to this date, the action for this deficiency shall be changed to a 60 (Rectify deficiencies prior to movement) and the vessel may no long be permitted to operate.
Action required: 705 - Other - as specified
Due 20 October 2020
Resolved 31 July 2020
Resolution: COI issued on 31JUL2020
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 13 July 2020
Resolved
A fixed fire pump must be capable of delivering water simultaneously from the two highest hydrants, or from both branches of a fitting if the highest hydrant has a Siamese fitting, at a pitot-tube pressure of at least 344 kilopascals (kPa) (50 pounds per square inch (psi)), and a flow rate of at least 300 liters per minute (lpm) (80 gallons per minute (gpm)). The vessel's fire main was unable to deliver water simultaneously from the two highest hydrants at a pitot-tube pressure of at least 50 psi.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 July 2020
Resolved 31 July 2020
Resolution: Fire pump was run ant tested sat.
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access Shore - Ship
Issued 13 July 2020
Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards. Marine Inspectors discovered two panel boards with openings where breakers/blanks are intended to be installed posing a shock hazard to crewmembers.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 July 2020
Resolved 31 July 2020
Resolution: Blanks installed in openings in distribution panels.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 13 July 2020
Resolved
Electrical components that pose an electrical hazard must be in an enclosure. Marine Inspectors discovered wires on the starboard main engine which were not in an enclosure.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 July 2020
Resolved 31 July 2020
Resolution: Wires were placed in an enclosure.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 13 July 2020
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons on board under normal and emergency conditions. Light fixture in the generator room was not properly secured and dangling from the ceiling. Corrected on the spot.
Action required: 10 - Deficiency Rectified
Resolved 13 July 2020
Resolution: Clear on spot. Light remounted properly.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 13 July 2020
Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards. Pressure switch on the compressed air pressure vessel was missing a cover and had exposed wiring. Corrected on the spot.
Action required: 10 - Deficiency Rectified
Resolved 13 July 2020
Resolution: Cover installed on pressure switch to cover exposed wiring.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 13 July 2020
Resolved
Electrical connections must be suitably installed to prevent them from coming loose through vibration or accidental contact. The battery installation for the skiff winch at the forward end of the engine room was found unsecured. Corrected on the spot.
Action required: 10 - Deficiency Rectified
Resolved 13 July 2020
Resolution: Battery secured with strap to prevent shifting.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 13 July 2020
Resolved
Except as provided in 173.17, no person may use a vessel to which this part applies unless: It has a number issued in a certificate of number by the issuing authority in the State of principal operation; and the number is displayed as described in 173.27. The skiff was not registered with the state. Vessel shall submit proof of initiating state registration process.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 August 2020
Resolved 21 October 2021
Resolution: Annual COI was conducted on this day and def was confirmed cleared.
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 13 July 2020
Resolved
To stop the flow of fuel in the event of a fire or break in the fuel line, a remote shutoff valve must be fitted on any fuel line that supplies fuel directly to a propulsion engine or generator prime mover. The valve must be installed in the fuel piping directly outside of the fuel oil supply tank. Marine Inspectors discovered the fuel oil shutoffs were not installed directly outside of the fuel oil tanks. Provide a plan to meet the requirements in 46 C.F.R. 143.260. Please include a diagram of the current configuration of the fuel supply piping, as well as a diagram of the proposed modification to the system. The plan shall include a description of the modification, as well as a proposed timeline for repair.
Action required: 705 - Other - as specified
Due 31 October 2020
Resolved 21 October 2021
Resolution: Annual COI was conducted on this day and def was confirmed cleared.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 13 July 2020
Resolved
Electrical connections must be suitably installed to prevent them from coning loose through vibration or accidental contact. Marine Inspectors discovered several connections on the starboard main engine were made with wire nuts without electrical tape to secure them from coming loose.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 July 2020
Resolved 31 July 2020
Resolution: Wires were appropriately secured to prevent them from coming loose through vibration.
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 13 July 2020
Resolved
Each towing vessel must have a reliable means to provide notification when an emergency condition exists or an essential system develop problems that require attention.
Marine Inspectors were not able to verify functionality of the port generator low lubricating oil pressure or high cooling water temperature on any engine. Functionality of these alarms must be demonstrated to the attending Marine Inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 July 2020
Resolved 31 July 2020
Resolution: Vessel proved satisfactory operation of all required alarms.
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 13 July 2020
Resolved
Engine alarms must be visible and audible at each operating station.
Alarms on bridge were not audible. Regulation must be met to the satisfaction of the attending Marine Inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 July 2020
Resolved 31 July 2020
Resolution: Vessel now has audible and visual alarms for all required alarms at the operating station.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 13 July 2020
Resolved
Lifejackets must be fitted with a lifejacket light approved under approval series 161.012 or 161.112 securely attached to the front shoulder area of the lifejacket.
02 lifejacket lights were inoperable. Lifejacket lights must be repaired or replaced to the satisfaction of the attending Marine Inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 July 2020
Resolved 31 July 2020
Resolution: Vessel acquired and replaced the lights on the required lifejackets.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 13 July 2020
Resolved
Lifejackets and lifebuoys must be marked in block capital letters with the name of the vessel.
02 lifejackets were not marked with the vessel's name. The name stickers were coming off of multiple lifebuoys. All lifejackets and lifebuoys must be appropriately marked to the satisfaction of the attending Marine Inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 July 2020
Resolved 31 July 2020
Resolution: Vessel properly stenciled the lifejackets.
Navigation › Piloting/Steering › Magnetic Compass
Issued 14 January 1998
Resolved
VSL HAS NO MAGNETIC COMPASS OR SWING METER._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 13 February 1998
Resolved 4 September 2007
Resolution: Admin clean-up of old MSIS cases.
Navigation › Piloting/Steering › Local Notices to Mariners
Issued 14 January 1998
Resolved
VSL HAS NO COAST GUARD LOCAL NOTICE TO MARINERS ON BOARD.
Condition: Unknown
Due 13 February 1998
Resolved 4 September 2007
Resolution: Admin Clean-up of old MSIS cases.
Engineering › Fuel Oil Storage/Transfer System › Ventilation
Issued 14 January 1998
Resolved
FUEL VENTS MISSING FLAME SCREENS._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 13 February 1998
Resolved 4 September 2007
Resolution: Admin clean-up of old MSIS cases.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 14 January 1998
Resolved
THE OFFICIAL NUMBER WAS NOT CLEARLY VISIBLE ON THE INTERIOR STRUCTURAL PARTOF THE HULL.
Condition: Unknown
Due 13 February 1998
Resolved 4 September 2007
Resolution: Admin clean-up of old MSIS cases.
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 14 January 1998
Resolved
NO NAME OR HAILING PORT ON THE STERN OF THE VSL._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 13 February 1998
Resolved 4 September 2007
Resolution: Admin clean-up of old MSIS cases.
Accommodation/Occupational Safety › Washroom/Toilet › Location
Issued 14 January 1998
Resolved
MSD TYPE NOT MARKED ON THE MSD AND VSL HAD NO PAPERWORK LISTING TYPE._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 13 February 1998
Resolved 4 September 2007
Resolution: Admin clean-up of old MSIS casework