Registered dimensions (L × B × D)60.4 ft × 24.0 ft × 5.7 ft
Registered tonnagegross 95 / net 65
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBALBOUR METAL BOAT WORKS · ST. LOUIS, MO, UNITED STATES · built 1960
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portST LOUIS, MO
Endorsements, as the file codes themcw_un, reg
DocumentationValid · issued 15 November 2025 · expires 31 December 2026
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it95 - Regulatory (Subpart C or D), Gross Ton 65 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel
Behind this panel: 20 inspections, each with its date, unit and type; 8 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; 14 other vessels inspected with it; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast
Guard wrote; the counts above are the same counts as in the summary, and they are free.
Professional is $39 a month or $299 a year,
or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks
every detail section on every vessel page, fleet watch tied to your account, and ownership records
on request. Already a subscriber? Sign in.
Maury does not score, rate or grade vessels, at any price.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 1972 to
2026, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
The Coast Guard recorded this vessel and the following in the same
inspection activity — normally a tug and the barges in its tow. A recreational or
unclassed hull in the same activity is held and not published, so it does not appear
here: these lists are a floor, not a complete manifest.
Vessel required to have a general alarm. General alarm did not actuate when the vessel master attempted to energize the alarm at the operator's station.
Action required: 17 - Rectify deficiencies prior to departure
Due 30 November 2021
Resolved 30 November 2021
Resolution: Electrician immediately dispatched to vessel, fuse replaced, and system operation restored. A check of records noted alarm is routinely checked and vessel master stated the alarm was checked prior to inspection without any issues.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 30 November 2021Resolved
Lifejackets must have a lifejacket light. Two lifejackets located in crew berthing did not have lights.
Action required: 10 - Deficiency Rectified
Due 30 November 2021
Resolved 30 November 2021
Resolution: Lights attached to lifejackets.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 30 November 2021Resolved
All lifesaving equipment must be tested and maintained IAW 46 CFR 199.190. Two lifejackets stowed under pilot house had lifejacket lights that were missing batteries.
Action required: 10 - Deficiency Rectified
Due 30 November 2021
Resolved 30 November 2021
Resolution: Lights inspected, batteries replaced, and operation of lights restored.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 30 November 2021Resolved
Berthing spaces must be equipped with a means to detect smoke. Port side crew berthing did not have a means to detect smoke.
Action required: 10 - Deficiency Rectified
Due 30 November 2021
Resolved 30 November 2021
Resolution: Individual battery operated detector meeting UL217 installed in space.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 30 November 2021Resolved
Vessel must be operated in such a manner as to afford protection against hazards. Vessel equipped with fire main to meet 46 CFR 142.325. Upon testing fire main an open valve in a branch line discharged a constant stream of water on the deck in the vicinity of the hose station. Valve could not be immediately closed due to missing handle from valve. A flooded deck without means to secure discharge would induce a hazard in an emergency. Temporary means employed (i.e. valve closed with add of tool), however, current configuration of branch line necessitates a permeant solution to eliminate potential hazard.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 December 2021
Resolved 2 December 2021
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 30 November 2021Resolved
A remotely operated valve must be installed in the fuel piping directly outside of the fuel oil supply tank to stop the flow of fuel in the event of a fire or a fuel line break. At time of inspection remotely operated valves were located in branch lines in the vicinity of the engines being supplied and not directly outside of fuel oil supply tank (valves were installed at the proper location; however, they were not capable of remote operation).
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 December 2021
Resolved 2 December 2021
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 30 November 2021Resolved
An exposed hazard such as rotating machinery, must be protected by a cover, guard or rail. The vessel's port and starboard propeller shafts were not protected and vessel supplies were stored in the immediately vicinity of the rotating machinery.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 December 2021
Resolved 2 December 2021
09 - Working and Living Conditions › 092 - Working Conditions › Protection machines/parts
Issued 30 November 2021Resolved
Pressure vessel must be equipped with a relief valve. Relief valve attached to an air pressure discharge line with an isolation valve installed between the tank and the relief valve, the pressure vessel was not equipped with a relief valve.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 December 2021
Resolved 2 December 2021