Records from 1997 to 2026. Most recent: inspection, 25 June 2026.
Inspection history · 52
25 June 2026
Administrative Inspection
Administrative · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 8413636
24 January 2024
TPO Audit
Administrative · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 7857139
5 December 2023
Deficiency Check · Examination of Repairs · COI Inspection
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 7834188
22 September 2023
In-Service Inspection · Examination of Repairs · Damage Survey
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 7796948
11 September 2023
Type not recorded
No type recorded · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 7789744
24 April 2023
Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 7674540
23 April 2023
Damage Survey · Deficiency Check
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 7678877
12 December 2022
Type not recorded
No type recorded · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 7610980
11 August 2022
Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 7535285
9 May 2022
Administrative Inspection
Administrative · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 7446799
5 July 2021
Administrative Inspection
Administrative · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 7245139
28 March 2021
Type not recorded
No type recorded · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 7164990
15 March 2021
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 7157258
7 March 2021
Type not recorded
No type recorded · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 7152639
8 September 2020
Administrative Inspection · Initial Certification
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 7053160
6 September 2020
Type not recorded
No type recorded · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 7054567
16 March 2016
Type not recorded
No type recorded · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 5835475
13 November 2015
Type not recorded
No type recorded · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 5804396
15 March 2015
Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 5087439
16 November 2014
Type not recorded
No type recorded · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 5032847
16 October 2014
Type not recorded
No type recorded · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 5006709
23 March 2014
Type not recorded
No type recorded · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 4823859
29 July 2012
Type not recorded
No type recorded · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 4396867
9 January 2012
Type not recorded
No type recorded · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 4221848
29 July 2011
Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 4113557
18 July 2011
MTSA Verification · Industry Initiated Exam · Deficiency Check
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 4093901
4 March 2011
Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 3957820
6 April 2009
Type not recorded
No type recorded · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 3448795
27 January 2009
Type not recorded
No type recorded · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 3400697
21 January 2009
Deficiency Check
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 3397558
26 October 2006
Type not recorded
No type recorded · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 2810934
15 October 2006
Type not recorded
No type recorded · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 2803019
17 February 2006
Type not recorded
No type recorded · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 2589692
10 October 2005
Type not recorded
No type recorded · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 2511953
17 September 2004
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 2203214
3 July 2004
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 2184423
12 March 2004
Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 2177148
27 January 2003
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1735723
20 January 2003
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1734513
8 April 2002
Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1602373
2 April 2002
Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1599959
28 September 2001
Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 294183
26 December 2000
Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 33194
1 November 1999
Uninspected Towing Vessel
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 797879
19 July 1999
Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 72893
10 May 1999
Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 180488
6 March 1999
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 23181
31 January 1999
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 93817
9 September 1998
Uninspected Towing Vessel
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 799368
17 September 1997
Uninspected Towing Vessel
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 774413
13 January 1997
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 756386
7 January 1997
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 195938
02 - Structural Conditions › N/A - No Subsystem › Decks - cracking
Issued 14 December 2023
Resolved
The cognizant OCMI may require review of a vessels watertight and weather tight integrity. Multiple fractures were identified located on the vessels head log in board of the port tow knee. Provide repair plan, and crop/renew to good metal to the satisfaction of an attending Marine Inspector in accordance with NVIC 7-68.
46 CFR 144.330
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 January 2024
Resolution: Attended vessels and approved repairs on the vessels head log.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 14 December 2023
No resolution recorded
The cognizant OCMI may require review of a vessels watertight and weather tight integrity. Vessels aft voids were found with unapproved permanent repairs, multiple new doubler plates installed as repairs. Provide repair plan, and crop/renew to good metal to the satisfaction of an attending Marine Inspector in accordance with NVIC 7-68/CVC Policy Letter 21-03.
Vessel is authorized to install doubler plates as a temporary repairs in aft void space. All new doubler plates are to be permanently marked to be identified. Vessel is required to complete permanent repairs at the next scheduled dry dock period.
46 CFR 144.330
Condition: Invalid
Action required: 705 - Other - as specified
Due 30 June 2026 — due date passed with no resolution recorded
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 7 December 2023
No resolution recorded
The cognizant OCMI may require review of a vessels watertight and weather tight integrity. Vessels starboard kort nozzle was found with several pin holes/failed welds impairing the watertight integrity. Determine condition of existing kort nozzle metal, provide repair plan, and crop/renew to good metal to the satisfaction of an attending Marine Inspector in accordance with NVIC 7-68/CVC Policy Letter 21-03.
46 CFR 144.330
Condition: Invalid
Action required: 705 - Other - as specified
Due 30 June 2026 — due date passed with no resolution recorded
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 26 September 2023
Resolved
A towing vessel must be maintained and operated so the watertight integrity and stability of the vessel are not compromised. The Port and STBD aft voids in way of rudder stock voids are taking on water at various places in bottom hull plating. One dewatering pump is in place and operating continuously and various other pumps are in place and operating intermittently to mitigate flooding and maintain stability. Survey the vessel to determine extent of the damage and provide thickness readings of all bottom plating prior to conducting repairs. Make repairs and conduct satisfactory NDT prior to returning to commercial service.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 23 January 2024
Resolution: Repairs completed.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 26 September 2023
Resolved
A towing vessel must be maintained and operated so the watertight integrity and stability of the vessel are not compromised. The Port and STBD shaft seal was observed leaking at a rate that the installed electro-submersible pumps are operating nearly continuously. Replace or adjust shaft seals to function as designed prior to returning to commercial service.
Action required: 30 - Ship detained
Resolved 1 February 2024
Resolution: Attended vessel, observed shaft seals were sufficient to prevent leaking in excess.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Reports of non-conf., accidents & hazardous occur.
Issued 26 September 2023
Resolved
The owner or managing operator of a towing vessel that has selected the TSMS option and who has chosen to demonstrate vessel compliance through an internal survey program must ensure that the TSMS applicable to the vessel includes: Procedures for documenting and reporting non-conformities and deficiencies. Crew members stated to the Marine Inspector that the vessel has been leaking from its hull for approximately 03 years. Provide all hull repair documentation, previous hull thickness readings, and reports of or company communication regarding flooding and related deficiencies onboard the vsl for the last 36 months.
Action required: 30 - Ship detained
Resolved 23 January 2024
Resolution: Documentation provided through HELM.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 26 September 2023
Resolved
All fire-detection systems on board a towing vessel must be maintained in accordance with the manufacturer's approved design manual or as otherwise provided in any TSMS applicable to the vessel. The vessel's fire detection panel displays a zone 04 (crew accommodation) fault. Repair the system and conduct a satisfactory test.
Action required: 30 - Ship detained
Resolved 1 February 2024
Resolution: Performed satisfactory test, all sat.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 26 September 2023
Resolved
Each towing vessel must be maintained and operated so as to minimize fire hazards and to ensure the following: (a) All bilges and void spaces are kept free from accumulation of combustible and flammable materials and liquids insofar as practicable. There is an excessive amount of lube oil accumulated in the engine-room bilges below each main engine. In addition, there is an excessive amount of fuel accumulated in the fuel-filter room bilge and the fwd-adjacent space's bilge. The vessel is fitted with a dedicated slop tank to store this fuel/lube oil. Remove the oil and fuel from all bilge spaces.
Action required: 30 - Ship detained
Resolved 23 January 2024
Resolution: L/O and F/O cleaned.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 26 September 2023
Resolved
All seals and gaskets must be properly maintained to prevent leaks of combustible liquid into the machinery space. Observed fuel being collected in a 5-gallon bucket from a leak under the Stbd Generator fuel filters. In addition, there is a fuel leak on the fuel supply line located in the overhead, centerline of the engine room. The crew is using sorbent material to collect the leak. Repair the leak and remove saturated rags in the vicinity. Provide verification of the pipe's integrity while at operating pressure after repairs are made.
Action required: 30 - Ship detained
Resolved 23 January 2024
Resolution: Leaks repaired.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 26 September 2023
Resolved
The master must ensure that all hatches, doors, and other openings designed to be watertight or weather-tight function properly. The Forward deck hatch-cover between the tow-knees does not latch or seal due to wastage. Repair/replace hatch combing and hatch to original condition.
Action required: 30 - Ship detained
Resolved 7 December 2023
Resolution: New scuttle installed.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 26 September 2023
Resolved
Piping and machinery components that exceed 220 °C (428 °F), including exhaust manifolds, and turbochargers, must be insulated. Port main engine and both service generators are missing turbo insulation on the exhaust side. Install/replace insulation.
Action required: 30 - Ship detained
Resolved 23 January 2024
Resolution: Insulation installed
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Company verification, review and evaluation
Issued 26 September 2023
Resolved
If the cognizant OCMI has reasonable cause to believe that a vessel's survey program is deficient, that OCMI may: (a) Require an audit or survey of the vessel in the presence of a representative of the cognizant OCMI. The deficiencies above indicate a failure of the vessel’s internal survey program. Complete an internal survey in the presence of a Marine Inspector or utilize TPO to verify compliance with subchapter M.
Action required: 30 - Ship detained
Resolved 23 January 2024
Resolution: Attended vessel and witnessed internal survey. Survey was conducted in compliance with subchapter M.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 26 September 2023
Resolved
All seals and gaskets must be properly maintained to prevent leaks of flammable or combustible liquid into the machinery space. Observed, oil accumulation on top of both main engines where exhaust manifolds mount. In addition, the oil filters on outboard side of the Starboard main engine leaking with one of the leaks being contained in a bucket. Also observed oil line on forward part of engine leaking oil. Correct oil leaks and provide verification with engines operating to the satisfaction of an attending Marine Inspector.
Action required: 30 - Ship detained
Resolved 23 January 2024
Resolution: Leaks repaired
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 26 September 2023
Resolved
Except as provided in paragraph (a)(8) of this section, each towing vessel must have a fire-detection system installed to detect engine room fires. The owner or managing operator must ensure the following: The system is installed, tested, and maintained in accordance with the manufacturer's design manual. Both engine room heat detectors found loosely mounted, dirty, and with exposed wiring. Return detectors to serviceable condition and conduct a test in accordance with company/TSMS procedures and in the presence of an attending CG MI.
Action required: 30 - Ship detained
Resolved 23 January 2024
Resolution: New installation
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 26 September 2023
Resolved
Pressure vessels over 5 cubic feet in volume and over 15 pounds per square inch maximum allowable working pressure (MAWP) must be equipped with an indicating pressure gauge (in a readily visible location) and with one or more spring-loaded relief valves. The total relieving capacity of such relief valves must prevent pressure from exceeding the MAWP, as established by the manufacturer, by more than 10 percent. Engine room Portside air receiver with a MAWP of 150 psi found with a 200psi relief valve installed. Replace with the appropriate relief valve prior to returning to commercial service to the satisfaction of the Marine Inspector.
Action required: 705 - Other - as specified
Resolved 23 January 2024
Resolution: Correct relief valve installed
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 26 September 2023
Resolved
The vessel must not incorporate or carry portable fuel systems, including portable tanks and related fuel lines and accessories, except when used for outboard engines or portable bilge or fire pumps. The design, construction, and stowage of portable tanks and related fuel lines and accessories must comply with the ABYC H–25 (incorporated by reference, see § 136.112 of this subchapter). Remove or prove the two portable fuel systems located above the engine room meet the ABYC H-25 standard prior to returning to commercial service.
Action required: 705 - Other - as specified
Resolved 23 January 2024
Resolution: Fuel caddy's removed from vessel.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 26 September 2023
Resolved
Each towing vessel must be equipped with a means to detect smoke in the berthing spaces and lounges that alerts individuals in those spaces. This may be accomplished by an installed detection system, or by using individual battery-operated detectors meeting UL 217. Smoke detector located in Master cabin above toilet found unmounted hanging by wires. Replace or refasten detector to its mount and conduct satisfactory test prior to returning to commercial service.
Action required: 705 - Other - as specified
Resolved 23 January 2024
Resolution: Detectors installed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 26 September 2023
Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards. Generator switchboard missing synchronizing light bulb and cover, grounding test buttons sticking when pressed, and excessive dust build up is accumulated within the panel. Repair missing cover and service sticking buttons on face of panel. Service and clean inside of panel to prevent fire hazard.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 January 2024
Resolution: Dead covers installed. Switch gear cleaned.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 26 September 2023
Resolved
An exposed hazard such as gears and rotating machinery, must be protected by a cover, guard or rail. Port and Starboard gear cooler pumps, as well as Port and Starboard Main engine Fuel oil pumps are missing protective covers around the shafts. Reinstall safety guards on all pumps with exposed rotating shafts.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 23 January 2024
Resolution: Guards installed.
02 - Structural Conditions › N/A - No Subsystem › Enhanced survey programme (ESP)
Issued 26 September 2023
Resolved
Rails or equivalent protection must be installed near the periphery of all decks accessible to crew. 08 Handrail stanchion posts are wasted causing posts to unmount from base welds. Replace/repair all affected stanchion posts to original.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 7 December 2023
Resolution: Wasted railings repaired.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 26 September 2023
Resolved
The fire main must have a sufficient number of fire hydrants with attached hose to allow a stream of water to reach any part of the machinery space using a single length of fire hose. The two STBD fire hoses were found not connected to their hydrants.
Action required: 10 - Deficiency Rectified
Resolved 26 September 2023
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 22 September 2023
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. The vessel's port rudder arm and starboard rudder arm connection pin sheared after hitting the bank as a result of a grounding. Make repairs prior to returning to commercial service.
Action required: 705 - Other - as specified
Resolved 1 February 2024
Resolution: Witnessed operational test of steering gear. All sat.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 22 September 2023
Resolved
A towing vessel must be maintained and operated so the watertight integrity and stability of the vessel are not compromised. During an inspection after the vessel grounded, CG Marine Inspectors determined the Stb aft, Port/Stbd Centerline, Port Aft, and Fwd Port voids are
taking on water. Make the voids safe for entry and
provide a Marine Chemist certificate for further
inspection. In addition, ensure the vessel's hull is
watertight prior to returning to commercial service to the satisfaction of attending marine
inspector.
Action required: 705 - Other - as specified
Resolved 1 February 2024
Resolution: Examined and approved vessels watertight integrity.
02 - Structural Conditions › N/A - No Subsystem › Bulkheads - cracking
Issued 23 April 2023
Resolved
The port #1 fuel tank was found leaking into the bow void due to a cracked weld in the fuel tank. Repair weld to allow use of the fuel tank.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 May 2023
Resolved 4 May 2023
Resolution: Repairs were to the satisfaction of the RO, using NVIC 7-68 as guidance for tests.