Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Registered dimensions (L × B × D)308.0 ft × 54.0 ft × 16.0 ft
Registered tonnagegross 2,235 / net 2,235
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderTRINITY MARINE PRODUCTS INC · ASHLAND CITY, TN, UNITED STATES · built 2006
Hull materialSteel
PropulsionNone
Hull shapeBox
Hull configurationMonohull
Hailing portBALTIMORE, MD
Endorsements, as the file codes themcw_un, reg_nfv
DocumentationValid · issued 14 November 2025 · expires 31 October 2026
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it2235 - Simplified, Gross Ton 2235 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel
Behind this panel: 38 inspections, each with its date, unit and type; 13 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; 9 other vessels inspected with it; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast
Guard wrote; the counts above are the same counts as in the summary, and they are free.
Professional is $39 a month or $299 a year,
or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks
every detail section on every vessel page, fleet watch tied to your account, and ownership records
on request. Already a subscriber? Sign in.
Maury does not score, rate or grade vessels, at any price.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 1972 to
2026, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
The Coast Guard recorded this vessel and the following in the same
inspection activity — normally a tug and the barges in its tow. A recreational or
unclassed hull in the same activity is held and not published, so it does not appear
here: these lists are a floor, not a complete manifest.
All tank vessels, the construction or conversion of which is started on or after July 1, 1951, shall conform to the requirements in this subpart in construction of hulls. The hull and deckhouses shall be of steel or iron construction except that the pilothouse and decks over quarters may be constructed of wood. Scantlings, material, and workmanship, subdivision of cargo spaces, fitting of cofferdams, and testing of tanks shall be at least equivalent to the requirements of the American Bureau of Shipping or other recognized classification society. Vessel reported that while being pushed by tug RED HOOK (O.N. 1242683) that the vessel allied with a moored tug, GULF COAST (O.N. 653705)'s starboard bow. Provide a damage survey and a repair proposal to the satisfaction of the USCG.
46 CFR 32.60-1
705 c prior to commercial operations.
Action required: 705 - Other - as specified
Resolved 26 April 2024
Resolution: Attended vessel, observed no significant damage.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 25 February 2020Resolved
Gears, couplings, flywheels and all machinery capable ofinjuring personnel shall be provided with adequate covers or guards. Both generators were found with exposed, uncovered rotary belts that are potentially a hazard to anyone operating the machinery.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 March 2020
Resolved 23 March 2020
Resolution: Provided picture evidence of machinery guard installation.
Conduct stbd side hull/structural repairs repairs IAW 835, items 1-13.
46 cfr 31.10-21(c)
If during an ISE, CTIE or underwater survey, damage or deterioration to the hull plating, structural members or cargo tanks is discovered, the OCMI may require the vessel to be dry-docked or otherwise taken out of service to further access damage or to effect permanent repairs.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 12 April 2019
Resolved 8 April 2019
Resolution: Verified repairs in respective void tanks.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 14 March 2019Resolved
#1S High and overfill alarm junction box so there are no exposed wires.
n order to maintain system integrity, each individual electrical installation in a hazardous location must comply with NEC art. 500-505 modified by 46cfr 111.105-3
Condition: Damaged By Earlier Event
Action required: 10 - Deficiency Rectified
Due 25 March 2019
Resolved 14 March 2019
Resolution: Company sent picture of the repaired junction box.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 14 March 2019Resolved
Life ring and light were within the HAZ ZONE.
46 CFR 111.105-31(l)(iii)
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 14 March 2019
Resolved 25 March 2019
Resolution: Life ring and float light were moved out of the haz zone.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 14 March 2019Resolved
Life ring grab lines and reflective tape were deteriorated.
46 CFR 199.190
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 14 March 2019
Resolved 14 March 2019
Resolution: New life ring were installed.
Electrical › Electrical Distribution System (service) › Ground Detection
Issued 25 March 2015Resolved
There must be ground detection for each power distribution system that is isolated from the ship's service power system by transformers, motor generator sets, or other devices. The vessel does not have ground detection for its 240V electrical system.
Action required: 705 - Other - as specified
Due 4 June 2015
Resolved 1 June 2015
Resolution: Ground detection installed in the 240 v panel.
Electrical › Electrical Distribution System (service) › Neutral Ground
Issued 25 March 2015Resolved
Each distribution system having a neutral bus or conductor must have the neutral grounded. If the voltage of a distribution system is less than 1000 volts, line to line, a tank vessel must not have a grounded distribution system. The range and dryer contain floating neutrals and therefore need to be isolated via individual transformers to meet the requirements of grounding the neutrals.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 July 2015
Resolved 10 July 2015
Resolution: transformers isolating the wiring from the 240 v distribution panel have been installed in the drop ceiling.
Deck/Cargo › Vapor Control Systems › Liquid Overfill Protection
Issued 25 March 2015Resolved
Each cargo tank must be equipped with an intrinsically safe high level alarm that must alarm before the tank overfill alarm, but no lower than 95% of tank capacity. The high level alarm on cargo tank 3 Port is not alarming properly.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 April 2015
Resolved 8 April 2015
Resolution: MIs attended vessel and observed operational high and overfill level alarms on cargo tank 3 port.
Accommodation/Occupational Safety › Heating › Electric Air Heating Equipment
Issued 25 March 2015Resolved
Each heater for bulkhead mounting must have its top slanted or otherwise designed to prevent hanging anything on the heater. The heaters in the accommodation spaces do not have slanted tops.
Action required: 705 - Other - as specified
Due 22 April 2015
Resolved 8 April 2015
Resolution: MIs observed the addition of a slanted top to prevent hanging anything on heater. The additions were made to heaters in kitchen and head.
Operations/Management › Streamlined Inspection Program › VAP Review and Revision
Issued 12 April 2012Resolved
Relief valve on Air receiver not tested during as part of ICR. No data plate/tag on relief valve to indicate set lifting pressure of the valve.
Action required: 705 - Other - as specified
Due 12 May 2012
Resolved 24 October 2012
Resolution: Name plate data provided and confirmation that future revisions of SIP will include appropriate inspections of air receiver.
Construction/Loadline › Hull › Hull Plating
Issued 5 April 2007Resolved
Make permanent repairs to side shell fracture IWO #1 Stbd wing tank between side longs 2 and 3 at aft bulkhead creased during allision. Damage up to 1.5" deep x 18" long. One butt weld fractured
Action required: 705 - Other - as specified
Resolved 5 April 2007
Resolution: 5 April 2007: Attended barge DS-30 at Vane Brothers facility in Philadelphia, PA. Welding job satisfactory. Hose tested repair, no leakage identified, repair satisfactory.
Electrical › Electrical Distribution System (service) › Cable
Issued 21 March 2006Resolved
Wiring harness on both Prime movers do not meet Class 1, Division 1, standards. As per Policy letter D8(m) 02-2005, Issued 835 with completion date of 30 Aug 2006
Condition: Design Flaw
Due 1 April 2010
Resolved 1 November 2009
Resolution: Reissued under activity 3624786
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.