Records from 2008 to 2023. Most recent: inspection, 18 October 2023.
Documentation record
Registered dimensions (L × B × D)297.5 ft × 54.0 ft × 12.0 ft
Registered tonnagegross 1,619 / net 1,619
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderTRINITY MARINE PRODUCTS INC · ASHLAND CITY, TN, UNITED STATES · built 2008
Hull materialSteel
PropulsionNot recorded
Hull shapeBox
Hull configurationMonohull
Hailing portST LOUIS, MO
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 18 December 2025 · expires 31 January 2027
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it1619 - Simplified, Gross Ton
1619 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 28
18 October 2023
Type not recorded
No type recorded · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 7814211
11 October 2023
Internal Structural Exam · MTSA Verification · COI Inspection · Examination of Repairs
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7803447
24 March 2023
Administrative Inspection · Examination of Repairs
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7656366
23 January 2020
In-Service Inspection · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6894927
8 October 2019
In-Service Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6830603
15 January 2019
COI Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6610750
6 December 2018
Cargo Tank Internal · Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6596170
19 July 2017
MTSA Verification · Administrative Inspection · Annual Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6246611
9 September 2016
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5996592
19 August 2016
Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 5979660
23 May 2016
Examination of Repairs
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 5880987
29 March 2016
Examination of Repairs
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5840631
1 February 2016
Damage Survey
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5807831
1 February 2016
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5811447
28 September 2015
Periodic Inspection · MTSA Verification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5730657
24 November 2014
Administrative Inspection · Annual Inspection
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 5030823
4 September 2014
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4974053
9 October 2013
COI Inspection · Administrative Inspection · Internal Structural Exam · MTSA Verification
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4731058
3 December 2012
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4493456
13 February 2012
MTSA Verification · Periodic Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4243321
4 August 2011
Type not recorded
No type recorded · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 4105852
25 February 2011
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3954605
9 December 2010
Annual Inspection · MTSA Verification
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3907535
12 October 2010
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3887740
2 September 2010
Type not recorded
No type recorded · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3840852
5 January 2010
Type not recorded
No type recorded · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3659222
25 May 2009
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3501437
27 October 2008
Internal Structural Exam · Initial Certification · Administrative Inspection · Initial Construction-Excluding Oversight · Cargo Tank Internal · MTSA Verification · Hull Examination
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 3352428
Pollution Prevention/Response › Prevention Equipment › Overfill Devices
Issued 19 August 2016
Resolved
Prove proper operation of the installed ERL High Level/Overfill alarms, IAW 46 CFR 39.20-9.
Action required: 705 - Other - as specified
Due 19 August 2016
Resolved 19 August 2016
Resolution: Barge rep found one of the back up batteries had low voltage. Rep replaced both batteries with new ones. All re-tested satisfactory.
Construction/Loadline › Hull › Side Shell
Issued 1 February 2016
Resolved
Deck gunnel buckled in #5 port wing void. Further structural survey required once barge is gas freed.
Action required: 705 - Other - as specified
Due 1 February 2016
Resolved 11 February 2016
Resolution: Received and accepted Surveyor Report with only scraped paint and no internal or external damage requiring repair.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Pump
Issued 30 September 2015
Resolved
No documentation of annual test of cargo pressure gauge or relief valve
Due 30 October 2015
Resolved 30 September 2015
Resolution: Received proper documentation for gauge and relief valve testing.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Pump
Issued 30 September 2015
Resolved
Prime mover RPM gaguge inoperative
Due 30 October 2015
Resolved 20 October 2015
Resolution: Received tech report attesting to installationand testing of RPM gauge.
25 May 2009Routine · role: Involved in a Marine Casualty · activity 3501437
5 January 2010Routine · role: Involved in a Marine Casualty · activity 3659222
2 September 2010Routine · role: Involved in a Marine Casualty · activity 3840852
12 October 2010Routine · role: Involved in a Marine Casualty · activity 3887740
25 February 2011Routine · role: Involved in a Marine Casualty · activity 3954605
4 August 2011Routine · role: Involved in a Marine Casualty · activity 4105852
1 February 2016Major Marine Casualty · role: Involved in a Marine Casualty · serious marine incident, as classified · 2 injured · activity 5811447
18 October 2023Routine · role: Involved in a Marine Casualty · activity 7814211
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source:
IIR, through 2026.