AURORA

AURORA is a 1970 towing vessel. The Coast Guard has recorded 68 inspections since 1989, most recently in May 2025, along with 40 deficiencies, 5 operational controls and 19 casualty investigations between 2004 and 2016.

Records from 1989 to 2025. Most recent: inspection, 14 May 2025.

Built
1970
Last inspected
14 May 2025
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Towing Vessel class in Maury's sources begin in 1980.

Inspection record

Last inspected 14 May 2025
…with no type recorded42
Operational controls None recorded without a removal date
Years with a record 28 calendar years (1989–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

7114018
WDJ8285
107271
Flag
UNITED STATES
Maury page id
psix-107271

Documentation record

Registered dimensions (L × B × D)91.5 ft × 26.8 ft × 9.7 ft
Registered tonnagegross 195 / net 132
ITC dimensions (L × B × D)Not recorded
ITC tonnagegross 229 / net 68
BuilderMAIN IRON WORKS INC · HOUMA, LA, UNITED STATES · built 1970
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portGUAYAMA, PR
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 8 June 2026 · expires 31 May 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it132 - Regulatory (Subpart C or D), Net Ton
229 - Convention (Subpart B), Gross Ton
68 - Convention (Subpart B), Net Ton
195 - Regulatory (Subpart C or D), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1980 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 13

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

DOUBLE SKIN 34 Tank Barge · MISLE 777826 · 25 March 2016 · activity 5857779DOUBLE SKIN 306 Tank Barge · MISLE 874079 · 25 March 2015 · activity 5090788DOUBLE SKIN 40 Tank Barge · MISLE 745729 · 22 May 2014 · activity 4870544FIRST COAST Towing Vessel · MISLE 97478 · 17 April 2014 · activity 4841451DOUBLE SKIN 204 Tank Barge · MISLE 1128698 · 25 June 2012 · activity 4358533VB 38 Tank Barge · MISLE 47764 · 20 December 2011 · activity 4212050VB 38 Tank Barge · MISLE 47764 · 4 December 2011 · activity 4202530DOUBLE SKIN 37 Tank Barge · MISLE 894681 · 23 October 2011 · activity 4176934VB 38 Tank Barge · MISLE 47764 · 14 June 2011 · activity 4152820VB 38 Tank Barge · MISLE 47764 · 30 July 2009 · activity 3558036DOUBLE SKIN 31 Tank Barge · MISLE 492191 · 20 February 2009 · activity 3423014VB 53 Tank Barge · MISLE 50783 · 6 April 2008 · activity 3180450VB 53 Tank Barge · MISLE 50783 · 27 December 2007 · activity 3121690WEEKS 99 Freight Barge · MISLE 46011 · 19 January 2004 · activity 1988269NTC 50 Freight Barge · MISLE 50788 · 23 May 2000 · activity 138092KTC-55 Tank Barge · MISLE 47337 · 21 November 1999 · activity 165576VB 53 Tank Barge · MISLE 50783 · 1 March 1998 · activity 74581KTC-71 Tank Barge · MISLE 228823 · 23 August 1995 · activity 35994

Inspection history · 68

14 May 2025 Administrative Inspection
Administrative · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 8136098
23 April 2025 Deficiency Check
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 8117488
17 March 2025 Administrative Inspection · Deficiency Check
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 8095311
6 March 2025 Deficiency Check · Administrative Inspection
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 8089230
14 January 2025 Deficiency Check
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 8063234
4 December 2024 Annual Inspection · Administrative Inspection
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 8042984
31 October 2023 Deficiency Check · Administrative Inspection
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 7818233
22 September 2023 DAPI Audit · COI Inspection · MTSA Verification
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7795736
27 June 2023 Drydock Exam · Internal Structural Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7694128
18 February 2023 MTSA Verification
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 7638631
15 September 2022 Annual Inspection · Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7559046
14 September 2021 Annual Inspection
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 7316986
31 August 2020 Deficiency Check
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 7046822
26 August 2020 Administrative Inspection
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7043195
21 April 2020 Initial Certification · DAPI Audit · MTSA Verification · Administrative Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6966921
22 November 2018 Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6586882
25 March 2016 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5857779
25 March 2015 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5090788
23 July 2014 Deficiency Check · Industry Initiated Exam · MTSA Verification · DAPI Audit
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4938638
22 May 2014 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4870544
17 April 2014 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 4841451
24 March 2013 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 4555878
21 February 2013 Type not recorded
No type recorded · USCGC CAPSTAN (WYTL 65601) · USCG East District (CGD-E) · Activity 4545287
15 September 2012 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4446000
25 June 2012 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 4358533
20 December 2011 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 4212050
5 December 2011 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 4201508
4 December 2011 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4202530
28 November 2011 Type not recorded
No type recorded · USCGC CLEAT (WYTL 65615) · USCG East District (CGD-E) · Activity 4197799
31 October 2011 Damage Survey
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4179673
23 October 2011 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4176934
14 June 2011 Type not recorded
No type recorded · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 4152820
4 February 2011 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3939470
4 February 2011 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3939507
4 February 2011 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3939572
4 February 2011 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 3942875
29 November 2010 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3900552
15 March 2010 Industry Initiated Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3697930
23 December 2009 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3660752
18 September 2009 Damage Survey
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3597498
16 September 2009 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3597459
30 July 2009 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3558036
27 April 2009 Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3470238
27 April 2009 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3478075
16 April 2009 Type not recorded
No type recorded · USCGC CLEAT (WYTL 65615) · USCG East District (CGD-E) · Activity 3454561
20 February 2009 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3423014
6 April 2008 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3180450
27 December 2007 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3121690
21 December 2007 Type not recorded
No type recorded · USCGC CLEAT (WYTL 65615) · USCG East District (CGD-E) · Activity 3123515
1 September 2005 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2547714
17 June 2005 MTSA Verification · Uninspected Other
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2393408
1 September 2004 Damage Survey
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2183558
19 January 2004 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1988269
7 October 2001 Type not recorded
No type recorded · USCGC GRAND ISLE (WPB 1338) · USCG Northeast District (CGD-NE) · Activity 1523970
27 October 2000 Uninspected Towing Vessel
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 823214
23 May 2000 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 138092
21 November 1999 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 165576
8 August 1999 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 181980
23 June 1998 Uninspected Towing Vessel
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1130275
1 March 1998 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 74581
25 October 1996 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 463015
23 August 1995 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 35994
3 August 1994 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 666991
26 July 1994 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 122491
26 July 1994 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 227358
17 February 1993 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 666977
11 February 1993 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 56349
24 December 1989 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 909451

Deficiency record · 40

07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 19 December 2024 Resolved
Where practicable and except as provided in § 144.515, each space where crew may be quartered or normally employed must have at least two means of escape. Install emergency exit in engine room. 46CFR144.500
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 January 2025
Resolved 14 January 2025
Resolution: Received photo evidence clearing def.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 19 December 2024 Resolved
Piping and machinery components that exceed 220 °C (428 °F), including fittings, flanges, valves, exhaust manifolds, and turbochargers, must be insulated. Install lagging on both main diesel engines and Both generators. 46CFR143.220 (b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 January 2025
Resolved 17 March 2025
Resolution: MI inspector received photos clearing deficiency.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 19 December 2024 Resolved
Electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. Install battery boxes for both generators.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 January 2025
Resolved 17 March 2025
Resolution: MI inspector received photos clearing deficiency.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 19 December 2024 Resolved
Machinery systems must be designed and maintained to provide for safe operation of the towing vessel. Install air filter on STBD generator. 46CFR143.205 (a)
Action required: 10 - Deficiency Rectified
Resolved 17 March 2025
Resolution: MI witnessed the instaltion of air filter.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 19 December 2024 Resolved
Machinery systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard. Install guard on STBD engine vibration dampener. 46CFR143.205 (a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 January 2025
Resolved 23 April 2025
Resolution: This office received photo evidence of the correction of deficiency.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 19 December 2024 Resolved
Machinery systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard. Install piping that directs hot water heaters relieve valve exhaust to bilge. 46CFR143.205 (a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 January 2025
Resolved 17 March 2025
Resolution: MI inspector received photos clearing deficiency.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 22 September 2023 Resolved
All bilges and void spaces must be kept free from accumulation of combustible and flammable materials. Excessive oil, oil-soaked dirt and debris and was found in the bilge. Remove excess oil, oil-soaked dirt and debris from vessel bilge. 46 CFR 142.220(a)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 November 2023
Resolved 13 November 2023
09 - Working and Living Conditions › 092 - Working Conditions › Protection machines/parts
Issued 22 September 2023 Resolved
Piping components that exceed 220 degrees C, including fittings, flanges, valves, exhaust manifolds, and turbocharges, must be insulated. Both port and starboard main engine exhaust lagging was unsecured. Secure both engines’ exhaust lagging. 46 CFR 143.220(b)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 November 2023
Resolved 10 November 2023
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 22 September 2023 Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards. Found in the forward most void space a wasted junction box, unsupported wires, and light fixtures with exposed bulbs. Replace junction box, support wires, and provide protection covers for light bulbs. 46 CFR 143.400(a)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 November 2023
Resolved 10 November 2023
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 22 September 2023 Resolved
Electrical systems must be designed and maintained to provide safe operation of the towing vessel and safety of persons on board. Starboard generator starting batteries and charger were loose, secure all components. Port and Starboard generator starting batteries are missing covers, install battery covers. 46 CFR 143.205(a)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 November 2023
Resolved 10 November 2023
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 22 September 2023 Resolved
Machinery must be maintained to provide safe operation of the towing vessel under normal and emergency conditions. The propulsion engines are started by air pressure and engine speed and direction controlled by air pressure. The port and starboard engine room pressure vessel popped style relief valves are 175 psi MAWP. The starboard relief valve relieved at 195 psi and did not reset after the air pressure fell to 50 psi, at which point it relief valve was closed by hand. The port pressure vessel relief valve relieved at 190 psi and reset at 150 psi. Industry standards for relief valve is to open and close is within +/- 10 of the MAWP (192.5 - 157.5 psi). Renew both pressure vessel relief valves. 46 CFR 143.205(a)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 November 2023
Resolved 10 November 2023
Resolution: VSL Crew replaced pressure relief valves.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 22 September 2023 Resolved
All installed bilge piping must have check/foot valves in each bilge suction that prevents unintended back flooding through bilge piping. Remove engine room deck plating and make bilge suctions and check valves available for inspection. 46 CFR 143.275
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 November 2023
Resolved 10 November 2023
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 22 September 2023 Resolved
Each towing vessel must be equipped with navigation lights in accordance with COLREGS or 33 CFR 84. Vessel stern mast light tree is dirty from exhaust. Clean navigation light lenses. 46 CFR 140.720
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 November 2023
Resolved 10 November 2023
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 22 September 2023 Resolved
The owner of a towing vessel must ensure that the vessel’s lifesaving equipment complies with the applicable requirements of parts 141 and 142 of this subchapter and is in good working order. On the 01 deck on the port quarter nearest the operating station the life buoy lanyard was wasted, and the water light did not operate. Replace lanyard and repair or replace water light. 46 CFR 140.650
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 November 2023
Resolved 10 November 2023
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 22 September 2023 Resolved
The owner of a towing vessel must ensure that the vessel’s fire suppression equipment complies with the applicable requirements of parts 141 and 142 of this subchapter and is in good working order. Found that the #3 fire extinguisher bracket, main ladder well has a broken securing device. Repair or replace securing device. 46 CFR 140.650
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 November 2023
Resolved 10 November 2023
01 - Certificates & Documentation › 012 - Crew Certificates › Medical certificate
Issued 22 September 2023 Resolved
The Coast Guard will issue a medical certificate to a mariner meeting the medical and physical standards for merchant mariners. 01 Able Seaman and 01 Ordinary Seaman did not have valid medical certificates on board, MMC reference numbers 8531143 and 2528848. Provided valid medical certificates prior to them working on the vessel under commercial operation. 46 CFR 10.301(a)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 November 2023
Resolved 10 November 2023
Resolution: Vessel rep provided email proof that the certs were sent to MMC.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 15 September 2022 Resolved
Closure devices must be provided for deckhouse or hull penetrations, which open to the exterior of the vessel and which may allow water to enter the vessel. These devices must be suitable for the expected route. Port main deck watertight door leading to the engine compartment was found to be warped and unable to provide watertight integrity.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 September 2022
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 15 September 2022 Resolved
Each towing vessel must have a reliable means to provide notification when an emergency condition exists or an essential system develops problems that require attention. Alarms must be visible and audible at each operating station. Audible alarms located at bridge for vessel essential systems including MDE, Aux gen, bilge and hydraulic steering were present but faint requiring volume adjustment to ensure recognition during normal operations.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 September 2022
Resolved 30 September 2022
Resolution: Audible alarm volume adjusted at the bridge to ensure recognition. Video attached.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 15 September 2022 Resolved
The frame or support of any semi-portable fire extinguisher fitted with wheels must be welded or otherwise permanently attached to a steel bulkhead or deck to prevent it from rolling under heavy sea conditions. The semi-portable fire extinguisher was secured to a railing and not permanently attached. In addition the frame was found to be rusted and wasted requiring replacement.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 September 2022
Resolved 30 September 2022
Resolution: Frame repaired and bottle fitted with securing devices to prevent rolling in heavy seas. Pictures attached.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 15 September 2022 Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard. Install fuel containment bowls under port and starboard generator fuel filters.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 September 2022
Resolved 3 October 2022
Resolution: heat shield bowls installed under fuel filters
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 15 September 2022 Resolved
Each towing vessel must be equipped with navigation lights, in accordance with the International Regulations for Prevention of Collisions at Sea (COLREGS) or 33 CFR part 84 as appropriate to its area of operation. Navigation lights on mast and stern of vessel are dirty and discolored from exhaust. Requires cleaning or replacement.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 September 2022
Resolved 30 September 2022
Resolution: Nav lights on mast cleaned to satisfaction of [name withheld] attached.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 15 September 2022 Resolved
Each towing vessel must be maintained and operated so as to minimize fire hazards. Propane cylinder on aft main deck was not secured to the bulkhead properly. Cylinder was removed from vessel during inspection and wont be placed on board until a proper securing device is available.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Resolved 15 September 2022
09 - Working and Living Conditions › 092 - Working Conditions › Ropes and wires
Issued 14 September 2021 Resolved
The owner, managing operator, master or officer in charge of a navigational watch of a towing vessel must ensure the following: The strength of each component used for securing the towing vessel to the tow and for making up the tow is adequate for its intended service. Stern towing cable has visible tares on its outer shell. Replace wire. 46CFR140.801(a).
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 16 September 2021
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 14 September 2021 Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard. Install fuel impeachment bowls on Port generator. 46CFR143.205 (a)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 21 September 2021
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 18 June 2020 Resolved
Vessel's fire detection must be certified by a Professional Engineer, NICET technician, or authorized class society under subchapter M. Vessel does not have record demonstrating compliance of installed system.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 July 2020
Resolved 25 June 2020
Resolution: Operating manager provided copy of approval letter.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 18 June 2020 Resolved
Electrical equipment must minimize system failure and fire and shock hazards. Bus bridge must be installed to prevent both generators from operating simultaneously.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 July 2020
Resolved 31 August 2020
08 - Alarms › N/A - No Subsystem › Fire alarm
Issued 18 June 2020 Resolved
Electrical equipment must minimize system failure and fire and shock hazards. Bus bridge must be installed to prevent both generators from operating simultaneously.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 July 2020
Resolved 31 August 2020
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 18 June 2020 Resolved
Each towing vessel must be equipped with an appropriate first aid kit. Several medications are outdated.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 July 2020
Resolved 31 August 2020
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 18 June 2020 Resolved
Electrical equipment must minimize system failure and fire and shock hazards. Batteries were found unsecured under the computer.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 July 2020
Resolved 31 August 2020
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 18 June 2020 Resolved
Towing vessels must be equipped with a proper compass. Compass deviation is from 27Feb2018.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 July 2020
Resolved 31 August 2020
11 - Life Saving Appliances › N/A - No Subsystem › Line-throwing appliance
Issued 18 June 2020 Resolved
Line throwing appliances must be approved under 160.040. Vessel is missing 3 line throwing appliances.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 July 2020
Resolved 31 August 2020
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 18 June 2020 Resolved
Electrical equipment must minimize system failure and fire and shock hazards. Surge protector cannot be daisy chained.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 July 2020
Resolved 31 August 2020
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 18 June 2020 Resolved
Electrical equipment must minimize system failure and fire and shock hazards. Light covers were found to be missing around the ship.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 July 2020
Resolved 31 August 2020
01 - Certificates & Documentation › 012 - Crew Certificates › Record of employment
Issued 18 June 2020 Resolved
An individual must pass a chemical test prior to employment. Temporary employees did not conduct required drug testing.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 July 2020
Resolved 31 August 2020
01 - Certificates & Documentation › 012 - Crew Certificates › Other (STCW)
Issued 18 June 2020 Resolved
Vessel must ensure EAP training is conducted. 60 minutes of supervisory training was not completed.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 July 2020
Resolved 25 June 2020
Resolution: Operating manager demonstrated comliance.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 18 June 2020 Resolved
Vessel must have EAP for all crewmembers. Vessel did not have training poster posted.
Action required: 10 - Deficiency Rectified
Due 18 July 2020
Resolved 18 June 2020
Resolution: Operator posted sign at the conclusion of the exam.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 18 June 2020 Resolved
Vessel must record drills. Vessel was found to be missing records of drills.
Action required: 10 - Deficiency Rectified
Resolved 18 June 2020
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 18 June 2020 Resolved
Pryotechnics must be carried at the operating station. Pryotechnics were found stored in the computer room.
Action required: 10 - Deficiency Rectified
Due 18 July 2020
Resolved 31 August 2020
Resolution: Pyrotechnics were moved to the operating station.
Deck/Cargo › Towing › Winch
Issued 1 September 2004 Resolved
While vessel was towing a barge the winch let go un-spooling the entire towrope. At this time the actual cause of the incident is unknown. Vessel is having a surveyor attend the vessel to assist in the identification and repair of the problem.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 7 September 2004
Resolution: Failure was found to human error.
Engineering
Issued 24 December 1989 Resolved
DEMONSTRATE PROPER OPERATION OF VESSEL THROTTLE CONTROLS PRIOR TO OPERATION(MANEUVERING) OF VESSEL.
Condition: Unknown
Due 24 December 1989
Resolved 24 December 1989

Casualty record · 19

19 January 2004Routine · role: Moored/Anchored in Vicinity of Primary Subject · activity 1988269
27 December 2007Routine · role: Involved in a Marine Casualty · activity 3121690
6 April 2008Routine · role: Involved in a Marine Casualty · activity 3180450
20 February 2009Routine · role: Involved in a Marine Casualty · activity 3423014
27 April 2009Routine · role: Involved in a Marine Casualty · activity 3478075
30 July 2009Routine · role: Involved in a Marine Casualty · activity 3558036
16 September 2009Routine · role: Involved in a Marine Casualty · activity 3597459
23 December 2009Routine · role: Involved in a Marine Casualty · activity 3660752
14 June 2011Routine · role: Involved in a Marine Casualty · activity 4152820
23 October 2011Routine · role: Involved in a Marine Casualty · activity 4176934
4 December 2011Routine · role: Involved in a Marine Casualty · activity 4202530
20 December 2011Routine · role: Involved in a Marine Casualty · activity 4212050
25 June 2012Routine · role: Involved in a Marine Casualty · activity 4358533
15 September 2012Routine · role: Involved in a Marine Casualty · 1 injured · activity 4446000
24 March 2013Routine · role: Involved in a Marine Casualty · activity 4555878
17 April 2014Routine · role: Transiting Vicinity of Primary Subject · activity 4841451
22 May 2014Routine · role: Moored/Anchored in Vicinity of Primary Subject · serious marine incident, as classified · 1 injured · activity 4870544
25 March 2015Routine · role: Involved in a Marine Casualty · activity 5090788
25 March 2016Routine · role: Involved in a Marine Casualty · activity 5857779
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

ENDEAVOR (2004–2016). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.