Records from 2012 to 2026. Most recent: inspection, 10 July 2026.
Documentation record
Registered dimensions (L × B × D)227.9 ft × 52.0 ft × 13.0 ft
Registered tonnagegross 1,200 / net 1,200
ITC dimensions (L × B × D)227.9 ft × 52.0 ft × 13.0 ft
ITC tonnagegross 1,679 / net 505
BuilderCONRAD INDUSTRIES INC · MORGAN CITY, LA, UNITED STATES · built 2011
Hull materialSteel
PropulsionNot recorded
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portHOUMA, LA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 28 May 2026 · expires 30 June 2027
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it1679 - Convention (Subpart B), Gross Ton
1200 - Regulatory (Subpart C or D), Gross Ton
505 - Convention (Subpart B), Net Ton
1200 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 29
10 July 2026
MTSA Verification · Examination of Repairs · COI Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 8421487
2 July 2026
In-Service Inspection · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8425994
2 March 2023
Deficiency Check · Examination of Repairs
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7644381
8 December 2022
Administrative Inspection · Damage Survey
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7605986
24 August 2021
Internal Structural Exam · COI Inspection · Examination of Repairs · Hull Examination · MTSA Verification · Cargo Tank Internal
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7292058
12 August 2021
MTSA Verification · Administrative Inspection · In-Service Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7284746
16 April 2019
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6841433
15 February 2019
Annual Inspection · Administrative Inspection · MTSA Verification
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6637376
12 December 2017
COI Inspection · MTSA Verification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6323316
17 August 2017
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 6247345
15 August 2017
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6241599
28 July 2017
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6223722
19 October 2016
Examination of Repairs · Damage Survey
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6032530
30 September 2016
Damage Survey
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6013031
30 September 2016
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6178476
16 May 2016
Internal Structural Exam · MTSA Verification · COI Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5875629
13 October 2015
Examination of Repairs · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5741126
7 October 2015
Damage Survey · Permit to Proceed · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5737938
7 October 2015
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5798424
10 August 2015
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5206368
12 August 2014
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4952325
20 June 2014
MTSA Verification · Periodic Inspection · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4894334
17 June 2014
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4891224
30 June 2013
In-Service Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4649127
21 June 2013
Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 4639896
14 September 2012
Deficiency Check
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4441015
12 September 2012
Deficiency Check
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4439306
21 June 2012
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4351183
23 May 2012
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4318652
Operations/Management › Vessel Activity › Other
Issued 12 December 2017
Resolved
Tank barges must have an annual inspection to maintain a valid certificate of inspection. CI 1608 missed annual inspection window (ended 16 August 2017) and has been operating without a valid COI throughout the present day. Vessel is prohibited from continued operation until certificate of inspection can be renewed on board.
Action required: 705 - Other - as specified
Due 12 December 2017
Resolved 15 December 2017
Resolution: Conducted COI inspection, all sat. Issued Temp COI from SEC New Orleans. Removed previous COI that was set to expire in 2021.
Construction/Loadline › Hull › Hull Plating
Issued 30 September 2016
Resolved
Vessel experienced a casualty with an open hopper barge at the jetty entrance to Bayou Baptiste Collette. Damage spanned 12'x15' in the port bow rake including several crused transverse frames. Vessel must submit a repair proposal and test repairs to the satisfaction of the attending CG Marine Inspector prior to carrying cargo.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 September 2016
Resolved 1 November 2016
Resolution: Attended vessel verified repairs and witnessed NDT.
Construction/Loadline › Hull › Side Shell
Issued 7 October 2015
Resolved
Vessel sustained damage on the STBD-side deck knuckle to the void space at about Frame #3, approx. 40 to 45 feet aft of the bow rake (head log). The damage covers an area of approx. 3 feet (in length) by 2 feet (in height), with an exposed hole into the void space (with an in-set of approximately 8 inches). Prior to any new cargo operations, the vessel shall effect repairs to the affected area.
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 October 2015
Resolved 13 October 2015
Resolution: Vessel replaced 4'X3' of side shell and sheer strake. All welds inspected and conducted water leak test. No leak evident. All repairs satisfactory.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Closure Devices
Issued 10 August 2015
Resolved
Two emergency shutdown valves located at the stbd stern of vessel failed to fully close during remote shutdown test. Per 46 CFR 38.10-1(H) (4) (i), they are required to do so.
Action required: 705 - Other - as specified
Due 10 September 2015
Resolved 12 August 2015
Resolution: The (2) starboard stern quick closing valves which failed to fully close during the previous inspection closed completely and functioned properly. Vessel repaired to the satisfaction of the CG marine inspector.
Deck/Cargo › Vapor Control Systems › Remotely Operated Cargo Vapor Shutoff Valve
Issued 23 May 2012
Resolved
Due to pending litigation with the barge, vsl rep doesn't expect the vessel to go back into service until September 2012 or later. Prior to transfer operations, demonstrate proper operation of Cargo Vapor Shutoff valves to the satisfaction of the attending USCG Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 September 2012
Resolution: Witnessed by USCG MI.