Records from 1996 to 2026. Most recent: inspection, 2 January 2026.
Inspection history · 66
2 January 2026
PSC A · Deficiency Check · COC-CVE Annual
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8287329
3 December 2024
Deficiency Check · PSC B · COC-CVE Annual
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8041364
18 February 2024
PSC A · COC-CVE Annual
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7867071
23 August 2023
PSC B · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7774468
15 August 2023
COC-CVE Quarterly · Administrative Inspection · PSC B · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7768443
12 July 2023
In-Service Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7740713
1 May 2023
Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7678924
25 February 2023
Deficiency Check · Ballast Water Examination · COC-CVE Annual · PSC A
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7641430
27 July 2022
COC-CVE Initial
Administrative · Activities Europe · Activity 7591164
22 September 2017
Administrative Inspection
Administrative · Activities Europe · Activity 6272327
22 September 2017
COC-CVE Initial Prep
Type not classified · Activities Europe · Activity 6272338
28 October 2015
Type not recorded
No type recorded · Activities Europe · Activity 5752381
27 April 2006
Type not recorded
No type recorded · Sector Key West · USCG Southeast District (CGD-SE) · Activity 2634726
1 December 2005
Ballast Water Examination · COC-CVE Annual · ISPS II Exam
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2544300
12 February 2005
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2291293
15 December 2004
Type not recorded
No type recorded · Sector Key West · USCG Southeast District (CGD-SE) · Activity 2259998
27 November 2004
STCW 95 Exam · MARPOL Annex I Examination · ISPS II Exam · MARPOL Annex V Examination · ILO-147 Exam · COC-CVE Annual
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2247323
22 April 2004
Control Verification
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2052792
12 April 2004
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2042212
11 March 2004
Damage Survey
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2022600
10 March 2004
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2023364
1 March 2004
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2015415
26 January 2004
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1992661
23 January 2004
Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1992826
15 January 2004
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1986533
22 December 2003
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1968112
11 December 2003
Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1962345
13 November 2003
Control Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1947094
18 May 2003
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1799630
5 May 2003
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1789838
28 April 2003
Quarterly Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1783533
7 April 2003
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1771968
17 March 2003
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1760656
7 March 2003
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1759700
7 March 2003
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1874124
7 March 2003
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1874302
17 February 2003
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1745498
13 January 2003
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1867265
10 January 2003
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1728517
13 December 2002
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1723361
22 November 2002
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1710959
22 November 2002
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1711561
11 November 2002
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1705920
11 November 2002
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1705923
6 November 2002
Control Verification · MARPOL Annex I Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1699026
15 September 2000
Control Verification · MARPOL Annex I Examination
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1420392
21 April 2000
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 113786
28 January 2000
Quarterly Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 814383
3 November 1999
MARPOL Annex I Examination · Control Verification
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1453686
15 September 1999
Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 432791
15 September 1999
Quarterly Examination
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1457695
24 April 1999
Quarterly Examination · MARPOL Annex I Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1360837
2 February 1999
Quarterly Examination · MARPOL Annex I Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1441446
6 January 1999
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 437294
8 November 1998
MARPOL Annex I Examination · Control Verification
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1364925
10 February 1998
Quarterly Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1394895
9 November 1997
Type not recorded
No type recorded · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 409667
9 November 1997
Deficiency Check · Control Verification
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1375180
7 March 1997
Type not recorded
No type recorded · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 401265
7 March 1997
Control Verification
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1371696
14 February 1997
Type not recorded
No type recorded · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 400546
14 February 1997
Quarterly Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1461762
16 November 1996
Quarterly Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 872924
16 November 1996
Control Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1459274
16 March 1996
Construction Oversight
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1459273
11 March 1996
Type not recorded
No type recorded · Activities Europe · Activity 1355849
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 2 January 2026
Resolved
Cylinders must be always be secured and, when not in use, they must be stowed in a rack in an upright position, with the valve protection cap in place. PSCO observed 05 gas cylinders without the protection valve cap installed in the oxygen storage room, deck 10.
46 CFR 147.60
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 January 2026
Resolved 9 January 2026
09 - Working and Living Conditions › 092 - Working Conditions › Other (working space ILO)
Issued 2 January 2026
Resolved
Electrical installations shall be such that the safety of passengers, crew and ship from electrical hazards shall be ensured. PSCO observed excessive condensation from ventilation line to electrical panel in vicinity of the sewage system monitoring panel.
74 SOLAS 04 II-1/40.1.3
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 January 2026
Resolved 9 January 2026
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 2 January 2026
Resolved
Activation of any local application system shall give a visual and distinct audible alarm in the protected space and at continuously manned stations. PSCO observed no visual and audible alarm for the protected space in vicinity of the #1 boiler when water mist system was activated.
74 SOLAS II-2/10.5.6.4
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 January 2026
Resolved 9 January 2026
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 2 January 2026
Resolved
Ventilation ducts passing through divisions between main vertical zones shall be equipped with a fail-safe automatic closing fire damper which shall also be capable of being manually closed from each side of the division. PSCO observed the close indication light for the fire ventilation dampers F4 11 02 and F4 11 05 were found inoperable.
74 SOLAS 01 II-2/41.2.6.3
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 January 2026
Resolved 9 January 2026
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 2 January 2026
Resolved
All life-saving appliances and arrangements shall comply with the applicable requirements of the Code. The engine shall be capable of operating for not less than 5 min after starting from cold with the lifeboat out of the water. PSCO found that the engine for lifeboat number 3 was found shutting off upon starting the engine.
74 SOLAS 20 III/34 LSA Code 4.4.6.3
Action required: 10 - Deficiency Rectified
Resolved 2 January 2026
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 3 December 2024
Resolved
Every crew member with assigned emergency duties shall be familiar with these duties before the voyage begins. PSCO identified that crew members assigned to deploy the liferaft did not demonstrated proficiency in a safe liferaft deployment process, needing constant instructions and commands from a senior officer. 74SOLAS(20)III/19.2.1.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 December 2024
Resolved 9 December 2024
Resolution: Video submitted of liferaft deployment found satisfactory.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 3 December 2024
Resolved
Fire doors in main vertical zones bulkheads and stairways enclosures local power accumulators for power operated doors shall be provided in the immediate vicinity of the doors to enable the doors to be operated at least 10 times using the controls. PSCO observed fire door 9.5 not releasing from the local release switch; and the fire door 9.02 striker plate is damaged preventing the door from closing in deck 9, forward buffet galley. 74SOLAS(97)II-2/30.4.4.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 December 2024
Resolved 9 December 2024
Resolution: Release button was repaired and found operable.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 3 December 2024
Resolved
Fire detection and fire alarms systems, shall be kept in good order so as to ensure their required performance if a fire occurs. PSCO observed an inoperable fire smoke detector #C0726 located in the main galley. 74SOLAS(20)II-2/14.2.1.1.2.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 3 December 2024
Resolution: Corrected on the spot by replacing the smoke detector.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 3 December 2024
Resolved
Fire doors in main vertical zones bulkheads and stairways enclosures local power accumulators for power operated doors shall be provided in the immediate vicinity of the doors to enable the doors to be operated at least 10 times using the controls. PSCO observed fire doors 1.37 and 4.36 not closing and not latching completely. 74SOLAS(97)II-2/30.4.1.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 3 December 2024
Resolution: Corrected on the spot by fixing the doors.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 23 August 2023
Resolved
Sprinklers shall be placed in an overhead position and spaced in a suitable pattern to maintain an average application rate... PSCOs observed sprinkler heads in stairways, spa area, steam room, and open deck areas that were recessed into the overhead that would prevent a constant flow of water into the designated space. Additionally, multiple sprinkler heads on the awning of the open deck were blocked by hanging canvas, thus disrupting the application rate of the water.
74 SOLAS (97) II-2/12.3
50ac
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 September 2023
Resolved 21 September 2023
Resolution: SEC NY PSC received class report attesting to repairs of blocked sprinkler heads. Report uploaded to documents.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 15 August 2023
Resolved
Doors and door frames in "B" class divisions and means of securing them shall provide a method of closure which shall have resistance to fire as far as practicable equivalent to that of the divisions except that ventilation openings may be permitted in the lower portion of such doors. Any such opening or openings shall not exceed 0.05 square m. When such opening is cut in a door it shall be fitted with a grill made of non-combustible material.
PSCO observed B-15 door was missing between nurse's station and corridor.
74 SOLAS 81 Amend II-2/31.1
17c
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 17 August 2023
Resolved 16 August 2023
Resolution: Vessel installed A-30 door.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 15 August 2023
Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use.
PSCOs observed the area on the bottom of the hull around the thru hull fitting for the hydrostatic release mechanism for lifeboat no. 8 to be cracked allowing water intrusion into the starboard side hull of the lifeboat.
Reduced max allowable total persons onboard to 2,650. (this reduction in total persons onboard and amendment to code 50ac were completed on 16AUG23. Deficiency initially issued as a 17ac)
74 SOLAS 20 III/20.2
50ac
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 September 2023
Resolved 21 August 2023
Resolution: Received class report attesting to proper repairs on lifeboat #8. Full term PSSC issued raising max allowable persons on board to 2800.
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 15 August 2023
Resolved
Every crew member with assigned emergency duties shall be familiar with these duties before the voyage begins.
PSCO observed a lack of crew knowledge in lifeboats #1, 3, 5, 7, 11.
74 SOLAS 20 III/19.2.1
17c
Action required: 17 - Rectify deficiencies prior to departure
Due 15 August 2023
Resolved 16 August 2023
Resolution: Upon returning to the vessel, PSCO observed satisfactory crew knowledge.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 15 August 2023
Resolved
This regulation applies to all passenger ships. The following doors, located above the margin line, shall be closed and locked before the ship proceeds on any voyage and shall remain closed and locked until the ship is at its next berth: cargo loading doors in the shell or the boundaries of the enclosed superstructures.
PSCO observed upper latch on side shell door 1.10 is inoperable.
74 SOLAS 04 II-1/20-1.2.1
17c
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 15 August 2023
Resolved 15 August 2023
Resolution: Determined to be an electrical issue. Repaired by crew.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 15 August 2023
Resolved
Fire doors in main vertical zone bulkheads and stairway enclosures, other that power-operated watertight doors and those which are normally locked, shall be of the self-closing type.
PSCO observed fire doors 1.23, 4.1, 4.2, 8.29, and 8.30 were incapable of fully self-closing.
74 SOLAS 81 Amend II-2/30.4
16c
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 August 2023
Resolved 15 August 2023
Resolution: Crew adjusted closing mechanisms for all doors to permit full closure.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Reports of non-conf., accidents & hazardous occur.
Issued 15 August 2023
Resolved
The safety management system should include procedures ensuring that non-conformities, accidents and hazardous situations are reported to the company, investigated and analyzed with the objective of improving safety and pollution prevention.
PSCO observed lifeboat #6 had damage to the starboard bow indicative of a collision. Upon questioning the crew, determined that the event/damage was never reported according to policy.
74 SOLAS 20 IX/3.1 and
ISM Code A.9.1
16ac
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 August 2023
Resolved 17 August 2023
Resolution: Received log of lifeboat crew SMS reporting procedures training completed on 16AUG23 from class, who had witnessed the training.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 15 August 2023
Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use.
PSCO observed a kinked temporary fuel line in lifeboat #4 as well as excessive oil in the bilge.
74 SOLAS 20 III/20.2
16ac
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 August 2023
Resolved 16 August 2023
Resolution: Crew replaced temporary section of hose with approved repair.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 15 August 2023
Resolved
Cylinders must always be secured and, when not in use, they must be stowed in rack in an upright position, with the valve protection cap in place.
PSCO observed that nitrogen cylinders were improperly stowed.
46 CFR 147.60(b)
16c
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 August 2023
Resolved 16 August 2023
Resolution: Crew placed all cylinders in a proper stowage rack.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 15 August 2023
Resolved
All doors shall be capable of remote and automatic release from a continuously manned central control station, either simultaneously or in groups, and also individually from a position at both sides of the door. Indication must be provided at the fire control panel in the continuously manned central control station whether each of the remote controlled doors are closed.
PSCO observed fire door 4.2 was equipped with a magnetic hold-back, but did not have an indicator light on the bridge.
74 SOLAS 97 II-2/30.4.3
50ac
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 September 2023
Resolved 16 August 2023
Resolution: Crew removed magnetic hold back.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 15 August 2023
Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use.
PSCO observed lifeboat #6 had multiple fractures in fiberglass on starboard bow above the waterline.
74 SOLAS 20 III/20.2
50ac
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 September 2023
Resolved 21 August 2023
Resolution: Received class report attesting to proper repairs on lifeboat #6.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 15 August 2023
Resolved
Crew members shall be trained to be familiar with the arrangements of the ship as well as the location and operation of any fire-fighting systems and appliances that they may be called upon to use.
PSCO observed the following during the initial fire drill: boundary cooling team went to the wrong location, leaving boundary unprotected. Additionally, attack team did not adequately secure door to affected space or secondary boundary upon exiting.
Upon conducting a second fire drill, crew performed in a satisfactory manner.
Action required: 10 - Deficiency Rectified
Due 15 August 2023
Resolved 16 August 2023
Resolution: Drill ran twice and second drill was satisfactory.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 25 February 2023
Resolved
07123 Fire hoses shall be of non-perishable material approved by the administration. 02 fire hoses on deck 4 port side when charged with firefighting water were leaking through pinholes. Additionally, the hydrant was also leaking when opened to allow water flow to hoses. Additionally, the fire station next to watertight door 0.14 was leaking out of the connection between the hose and hydrant. 74 SOLAS 97 II-2/4.7.1 (17ac).
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 February 2023
Resolution: Hoses have been replaced by new ones on board prior finishing the exam.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 25 February 2023
Resolved
07103 In addition to complying with the specific provisions for fire integrity of bulkheads and decks mentioned elsewhere in this part, the minimum fire integrity of bulkheads and decks shall be as prescribed in table 27.1 and table 27.2. PSCOs identified behind Gallery 47 restaurant, linen stored in the space behind the lining on installed shelving, with no fire detection or suppression present. 74 SOLAS 97 II-2/26.1 (17C)
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 February 2023
Resolution: Linen was removed and stored in an approved categorization space with fire protection and suppresion.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 25 February 2023
Resolved
07123 All nozzles shall be of an approved dual-purpose type. Nozzle attached to fire station TT04 within the engine room when charged with firefighting water was leaking when attempting to shutoff the spray of water. 74 SOLAS 97 II-2/4.8.4 (16C).
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 March 2023
Resolved 29 March 2023
Resolution: Nozzle was replaced with a new one.
07 - Fire Safety › N/A - No Subsystem › International shore-connection
Issued 25 February 2023
Resolved
07118 Ships of 500 gross tonnage and upwards shall be provided with at least one international shore connection complying with the provisions of paragraph 3. The connection shall be kept with a gasket of any suitable material, four 16mm bolts, 50 mm in length and eight washers. Shore connection on foc'sle, port side is missing all washers needed. 74 SOLAS 97 II-2/19.1 (16ac).
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 March 2023
Resolved 29 March 2023
Resolution: All washers and gaskets have been provided.
02 - Structural Conditions › N/A - No Subsystem › Stability/strength/loading information and instruments
Issued 25 February 2023
Resolved
02103 The means of cross flooding shall where practicable be self-acting but in any case, where controls to cross flooding fittings are provided, they shall be operable from above the bulkhead deck. These fittings together with their controls shall be acceptable to the Administration. Cross flooding devices open only in one direction and to a narrow gap. Documentation is needed to verify that the opening width and direction of cross flooding installation is sufficient for its intended use. 74 SOLAS 04 II-1/8.5 (16b).
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 March 2023
Resolved 1 May 2023
Resolution: Documents submitted by vessel owner/operator and Class Society Det Norske Veritas porvides enough information to opening with and directions is sufficient. CSNCOE ICOC Team Member accepted documents submitted, Sector San Juan Cleared the deficiency.
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 25 February 2023
Resolved
11131 Every crew member with assigned emergency duties shall be familiar with these duties before the voyage begins. PSCOs identified multiple crews during the abandon ship drill with stairway guide and muster station duties that were unfamiliar with their duties. Additionally, the life raft deployment team was unfamiliar with the procedures for launching and took coaching to complete. 74 SOLAS 20 III/19.2.1 (16a).
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 March 2023
Resolved 29 March 2023
Resolution: A list of training for crew members assigned to the lifesdaving equipment (liferagft) was provided. Also a list of training roster wasprovcided for stairway guides.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 25 February 2023
Resolved
07105 The construction of all doors and door frames in "A" class divisions shall provide resistance to fire as well as to passage of smoke and flame, equivalent to that of the bulkheads in which the doors are situated. PSCOs identified hose ports in sliding fire doors 7.19 and 8.26, when closed, left an inch gap between the doors. Fire door 11.8 had a hose port that would not close due to contact with the door sill. Fire door 11.15 would not close and securely latch when release from magnetic hold back. 74 SOLAS 97 II-2/30.7 (16a).
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 March 2023
Resolved 29 March 2023
Resolution: Corrections have been made to all hose ports and fire door is found to be closing correctly.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 25 February 2023
Resolved
07120 All escape route signs, and fire equipment location markings shall be of photoluminescent material. PSCOs identified during atrium smoke extraction testing, that decks 4,5,6 and 7 required additional exit signage on the starboard side walkway connecting the fore and aft portions. 74 SOLAS 97 II-2/41-2.4.7 (16ac).
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 March 2023
Resolved 29 March 2023
Resolution: Additionmal signange was installed as required.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 25 February 2023
Resolved
07120 All escape route signs, and fire equipment location markings shall be of photoluminescent material. On deck 5 in the Gallery 47 restaurant, PSCOs observed exit signage being blocked by panels in the way of service stations on both the port and starboard sides. 74 SOLAS 97 II-2/41-2.4.7 (16ac).
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 March 2023
Resolved 29 March 2023
Resolution: Signs have been relocated, and was found to be visible from any angle.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 25 February 2023
Resolved
07120 Stairways and ladders shall be arranged to provide ready means of escape to the lifeboat and life raft embarkation deck from passenger and crew spaces and spaces in which the crew is normally employed. The ship manager's office constitutes a room in room arrangement and lacks an operational audible alarm to alert occupants of fire outside the space. 74 SOLAS 97 II-2/28.1.2 (16a).
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 March 2023
Resolved 29 March 2023
Resolution: A smoke detector with an audible alarms has been installed and tested.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 25 February 2023
Resolved
07103 For determining the appropriate fire integrity standards to be applied to boundaries between adjacent spaces, such spaces are classified according to their fire risk as shown in categories (1) to (14). In fan room 221, a category 10 space, combustible materials were stored. 74 SOLAS 97 II-2/26.2.2 (10C).
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Resolved 25 February 2023
Resolution: Combustible materials have been removed and stowed in a fire suppresion protected compartment.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 25 February 2023
Resolved
07109 Sprinklers shall be placed in an overhead position and spaced in a suitable pattern to maintain an average application rate of not less than 51 square meters/min over the nominal area covered by the sprinklers. Engine storeroom forward on deck 2 had storage above the maximum storage height for the installed firefighting sprinklers in the space. 74 SOLAS 97 II-2/12.3 (10c).
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Resolved 25 February 2023
Resolution: Materials in the storage have been removed and stowed lower and under the coverage of low pressure sprinkler nozzles.
Communications › Alarms/Indicators › General Alarm
Issued 27 November 2004
Resolved
Provide/prove remote alarm in Galley office Deck 4. Identify need by 04 Dec 04.
Condition: Design Flaw
Due 3 December 2004
Resolved 4 December 2004
Resolution: cleared
Communications › Alarms/Indicators › General Alarm
Issued 27 November 2004
Resolved
Provide Remote alarm in Galley office deck 4 by 25Dec04.
Condition: Design Flaw
Due 25 December 2004
Resolved 4 December 2004
Resolution: cleared
Communications › Alarms/Indicators › Fire Alarm
Issued 27 November 2004
Resolved
Provide proper testing medium for testing Smoke and Heat dectores by 04Dec04.
Condition: Unknown
Due 3 December 2004
Resolved 4 December 2004
Resolution: cleared
Lifesaving › Lifeboat › Hull
Issued 27 November 2004
Resolved
Repair Hull Damage to Aft STBD corner of Lunch #6 to the satisfaction of Class and provide Class report to the US Coast Guard by 25Dec04
Condition: Damaged By Earlier Event
Due 25 December 2004
Resolved 12 February 2005
Resolution: OBTAINED REPORT FROM VESSELS CLASS, SOCIETY DET NORSKE VERITAS THAT THE HULL DAMAGE TO AFT STBD LAUNCH #6 WAS CORRECTED TO THE SATISFACTION OF THE ATTENDING MARINE SURVEYOR.
Lifesaving › Lifeboat › Markings
Issued 27 November 2004
Resolved
Renew Retro Tape as needed on Lifeboats as needed by 04Dec04
Condition: Unknown
Due 4 December 2004
Resolved 4 December 2004
Resolution: replaced
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 27 November 2004
Resolved
Have Class Attest to adequacy of A-60 FireDoors 0.53 and 0.55 (holed) or replace Doors. Provide Class report by 25 Dec04.
Condition: Unknown
Due 25 December 2004
Resolved 4 December 2004
Resolution: repaired.
Engineering › Diesel Engine (propulsion-electric)
Issued 11 March 2004
Resolved
PROVIDE CLASS REPORT ATTESTING TO THE PROPER OPERATION OF TEMPERATURE EXHAUST GAS SENSOR AND TEMPERATURE CYLINDER LINER SENSOR FOR ENGINES # 3,4, & 5.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 March 2004
Engineering › Lubricating Oil Service System › Filter
Issued 11 March 2004
Resolved
PROVIDE CLASS REPORT ATTESTING TO THE PROPER OPERATION OF THE #4 ENGINE AND LUBE OIL FILTERING SYSTEM.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 March 2004
Documentation
Issued 11 March 2004
Resolved
PROVIDE INVESTIGATION REPORT FOR THE REASON WHY THE FILTERING CYLINDERS WOULD NOT DEPRESSURIZE.
Due 11 April 2004
Resolved 12 April 2004
Engineering › Steering Gear System › Rudder
Issued 23 January 2004
Resolved
Make permanent repairs to Thruster #1 blade seal replacement prior to departing Pier 28 and fax report to GALMS, TX.
Due 23 January 2004
Resolved 23 January 2004
Resolution: Rcvd Maintenance specialist report on repairs.
Operations/Management › Drills/Instruction
Issued 13 November 2003
Resolved
Demonstrate satisfactory liferaft drill to the satisfaction of the attending US Coast Guard Marine Inspector. See narrative for specifics. LEGACY COMPONENT DESC: Abandon Ship
Action required: 705 - Other - as specified
Due 29 November 2003
Resolved 11 December 2003
Resolution: Witnessed satisfactory davit life raft launching drill.
Fire Fighting › Fixed Fire Detection System
Issued 28 April 2003
Resolved
Repair smoke detector C0857, deck 5 galley. LEGACY COMPONENT DESC: Smoke Detectors
Action required: 15 - Rectify deficiencies by next port
Resolved 28 April 2003
Resolution: Rcvd E-mail from Master [name withheld], that the item was corrected.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 28 April 2003
Resolved
Repair FSD 9.19
Action required: 15 - Rectify deficiencies by next port
Resolved 28 April 2003
Resolution: Rcvd E-mail from Master [name withheld], that the item was corrected.
Fire Fighting
Issued 9 November 1997
Resolved
PROVE OPERATION OF SPRINKLER PUMP PRIOR TO NEXT U.S. PORT.
Condition: Unknown
Due 9 November 1997
Resolved 9 November 1997
Lifesaving
Issued 16 November 1996
Resolved
MODIFY THE LIFE RAFT CRADLES AS DISCUSSED FOR THE PORT AND STBD SIDE AFT.
Condition: Unknown
Due 10 January 1997
Resolved 10 January 1997
Lifesaving
Issued 16 March 1996
Resolved
MODIFY BOTH PORT/STBD FWD EMBARKATION LADDERS.
Condition: Unknown
Due 16 March 1996
Resolved 16 March 1996
Lifesaving
Issued 16 March 1996
Resolved
REPLACE THE STBD EMBARKATION LADDER.
Condition: Unknown
Due 16 March 1996
Resolved 16 March 1996
Lifesaving
Issued 16 March 1996
Resolved
REPAIR THE AFT PORT/STBD LIFE RAFT CRADLES.
Condition: Unknown
Due 16 March 1996
Resolved 16 March 1996
Electrical
Issued 16 March 1996
Resolved
INSTALL "E" LIGHTS IN WAY OF MUSTER STATION 11 AND 12.
Condition: Unknown
Due 16 March 1996
Resolved 16 March 1996
Construction/Loadline
Issued 16 March 1996
Resolved
AT FRAME 132, 0 DECK, EMERGENCY ESCAPES FROM PUMP ROOM HOLD BACKS TO BE REMOVED.
Condition: Unknown
Due 26 November 1996
Resolved 26 November 1996
Electrical
Issued 16 March 1996
Resolved
INSTALL EMERGENCY LIGHTING IN WAY OF AFT PORT/STBD DAVITS.
Condition: Unknown
Due 16 March 1996
Resolved 16 March 1996
Fire Fighting
Issued 16 March 1996
Resolved
PROVIDE AN APPROVE COPY OF THE FIRE CONTROL PLAN.
Condition: Unknown
Due 26 November 1996
Resolved 26 November 1996
Lifesaving
Issued 16 March 1996
Resolved
MODIFY LIFERAFT CRADLES AS DISCUSSED.
Condition: Unknown
Due 16 March 1996
Resolved 16 March 1996
Lifesaving
Issued 16 March 1996
Resolved
AT FIRST US PORT, DEMONSTRATE THE PORT/STBD BOATS AND OPERATE THE RELEASINGGEARS.
Condition: Unknown
Due 16 March 1996
Resolved 16 March 1996