Records from 2002 to 2018. Most recent: operational control imposed, 23 November 2018.
Inspection history · 25
23 November 2018
ISPS II Exam · Ballast Water Examination · COC-TVE Annual
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6581786
23 November 2018
Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6585627
19 December 2017
Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6326333
14 November 2017
ISPS II Exam · Ballast Water Examination · COC-TVE Renew
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6302884
3 July 2016
ISPS II Exam · Ballast Water Examination · COC-CHEM & TVE Renew
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5928660
10 September 2008
COC-TVE Renew · ISPS II Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3316802
16 March 2006
Type not recorded
No type recorded · Station Pascagoula · USCG Heartland District (CGD-H) · Activity 2603968
16 March 2006
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2604290
12 March 2006
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2600777
21 October 2005
COC-TVE Annual · ISPS II Exam · Ballast Water Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2517524
12 September 2005
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2490767
2 May 2005
MARPOL Annex I Examination · ISPS II Exam · Re-Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2347209
28 April 2005
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2345064
23 January 2005
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2280137
23 January 2005
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2308105
19 January 2005
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2277705
18 October 2004
COC-TVE Renew
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2223389
27 May 2004
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2080174
25 May 2004
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2076590
21 April 2004
Ballast Water Examination · Re-Inspection · MTSA/ISPS Verification
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2049514
6 October 2003
Certificate of Compliance
Administrative · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1922061
5 May 2003
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1789838
25 March 2003
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1763288
24 March 2003
Security Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1763165
23 September 2002
Certificate of Compliance
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1678925
02 - Structural Conditions › N/A - No Subsystem › Cargo tank vent system
Issued 24 November 2018
Resolved
The term flame screen means a fitted single screen of corrosion resistant wire of at least 30 by 30 mes or two fitted screens, both of corrosion resistant wire, of at least 20 by 20 mesh, spaced not less than 1/2 inch or more than 1 1/2 inches apart. Flame screens to multiple pressure/vacuum valves and wing ballast tank found with missing flame screens. (PVs 4s, 1p, and WBP1)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 November 2018
Resolution: Flame screens were replaced with new in PV valves 4s, 1p and Water Ballast tank 1p.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 24 November 2018
Resolved
Maintenance, testing and inspections of life saving appliances shall be carried out based on the guidelines developed by the organization having due regard to ensuring reliablility of such appliances. Retroreflective tape found to be weathered to conditions rendering it not detectable for visual life saving search and rescue on both lifeboats and on multiple life bouys. SOLAS 74(2014 CONS) REG 20.3 16c
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 December 2018
Resolved 26 November 2018
Resolution: New retroreflective tape was placed on both lifeboats and required life bouys.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 24 November 2018
Resolved
Fire safety measures for tankers; Doors in fire resisting divisions; The fire resistance of doors shall, as far as practicable, be equivalent to that of the division in which they are fitted. Crew laundry class C door and drying room class B door are not installed as per ships fire plan. SOLAS74(2001) Reg. 47.1 17c
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 November 2018
Resolution: Crew laundry and drying room doors were replaced with proper fire class doors as per ships fire plan.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 14 November 2017
Resolved
Carbon dioxide systems installed on or after 1 October 1994 shall have two controls located inside a release box clearly identified for the particular space. If the box containing the controls is to be locked, a key to the box shall be in a break-glass-type enclosure conspicuously located adjacent to the box. PSCO observed lock on control box for CO2 discharge to engine room is missing and must be replaced with new. 74SOLAS(01) II-2/5.2.5.2 50a/c
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 December 2017
Resolved 19 December 2017
Resolution: Survey report states: New control boxes with new locks and key for Fixed CO2 Fire Extinguishing Systems station have been verified installed into position. The lock/unlock operation ability of provided keys were tried out in order.