Records from 1998 to 2004. Most recent: inspection, 7 January 2004.
Inspection history · 14
7 January 2004
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1978112
2 December 2003
Annual Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1959462
5 May 2003
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1789838
7 April 2003
Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1769628
1 April 2003
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1769728
10 March 2003
Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1755343
7 September 2002
Annual Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1672972
20 August 2001
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 292987
12 July 2001
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 291780
11 June 2001
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 290927
17 May 2000
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 277994
12 November 1999
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 434690
15 March 1999
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 426549
17 October 1998
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 421698
Pollution Prevention/Response › Prevention Equipment
Issued 2 December 2003
Resolved
Prior to next US port fix/repair mechanical means of closure for all containment boxes on deck. IAW 33 CFR 155.310. LEGACY COMPONENT DESC: Fixed Containment
Condition: Improper/Lack of Maintenance
Due 3 December 2003
Resolved 7 January 2004
Resolution: PROVIDED MECHANICAL MEANS OF CLOSURE FOR ALL CONTAINMENT BOXES ON DECK.
Lifesaving › Lifebuoys
Issued 2 December 2003
Resolved
Prior to next US port replace port side main deck midships lifebuoy IAW SOLAS 60 Chapter 3 Reg 4 (c). LEGACY COMPONENT DESC: Markings (ship name/port)
Condition: Improper/Lack of Maintenance
Due 3 December 2003
Resolved 7 January 2004
Resolution: PROVIDED NEW LIFEBUOY ON PORT SIDE MAIN DECK MIDSHIP.
Construction/Loadline › Markings
Issued 10 March 2003
Resolved
Prior to next US port, repaint load line on ship's hull. LEGACY COMPONENT DESC: Load Line Mark
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Due 11 March 2003
Resolved 7 April 2003
Resolution: Load line had been repainted on ship''s hull.
Electrical › Electrical Distribution System (service)
Issued 10 March 2003
Resolved
Prior to next US port, provide cover for unction box for Dumb Waiter control panel. LEGACY COMPONENT DESC: Junction Box
Condition: Unknown
Action required: 15 - Rectify deficiencies by next port
Due 11 March 2003
Resolved 7 April 2003
Resolution: Junction box cover for dumb waiter had been replaced.
Electrical › Electrical Distribution System (service)
Issued 10 March 2003
Resolved
Prior to next US port, provide Non-conductive deck covering in front of electrical panels in main engineering control room. LEGACY COMPONENT DESC: Non-conducting Deck Covering
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 11 March 2003
Resolved 7 April 2003
Resolution: Non-conductive deck coverings had been installed around electrical panels.
Electrical › Electrical Distribution System (emergency)
Issued 10 March 2003
Resolved
Prior to next US port, provide Non-conductive deck covering in front of electrical panel in emergency generator room. LEGACY COMPONENT DESC: Non-conducting Deck Covering
Condition: Unknown
Action required: 15 - Rectify deficiencies by next port
Due 11 March 2003
Resolved 7 April 2003
Resolution: Non-conductive deck coverings had been installed around electrical panels.
Fire Fighting › Fire Hoses
Issued 10 March 2003
Resolved
Prior to next US port, replace aft fire hose. LEGACY COMPONENT DESC: Condition
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Due 11 March 2003
Resolved 7 April 2003
Resolution: Fire hose had been replaced and was tested satisfactorily.
Operations/Management › Navigation Safety
Issued 10 March 2003
Resolved
When entering US ports, conduct pre-arrival tests as per 33 CFR 164.25 LEGACY COMPONENT DESC: Arrival/Departure Tests
Condition: Unknown
Action required: 15 - Rectify deficiencies by next port
Due 11 March 2003
Resolved 7 April 2003
Resolution: Pre-arrival tests were conducted and proper log entries had been made prior to entering port.
Construction/Loadline › Structures
Issued 10 March 2003
Resolved
Make repairs to flying bridge deck as per SOLAS II-1, 19.1 and to the satisfaction of certificat issueing authority prior to 10 APR 03 LEGACY COMPONENT DESC: Deck Plating
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 April 2003
Resolved 7 April 2003
Resolution: Deck covering was removed and deck had been preped, primed, and resurfaced.
Operations/Management › Drills/Instruction › Safety Orientation
Issued 10 March 2003
Resolved
Conduct drills priot to departure as per SOLAS III, 19.3.2
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 10 March 2003
Resolved 11 March 2003
Resolution: Drills were conducted prior to ship''s departure from port.
Fire Fighting
Issued 12 July 2001
Resolved
REPAIR, REMOVE, OR MARK AS INOP THE REMOTE CO2 STATION PRIOR TO DEPARTURE._x001C_SOLAS 60 REG. 11
Condition: Unknown
Due 6 August 2001
Resolved 6 August 2001
Fire Fighting
Issued 12 July 2001
Resolved
CORRECT FIRE CONTROL PLANS TO INDICATE BULKHEAD TYPES PRIOR TO NEXT U.S. PORT._x001C_ SOLAS 74(AMD) II-2/20
Condition: Unknown
Due 20 August 2001
Resolved 20 August 2001
Navigation
Issued 12 July 2001
Resolved
PROVIDE OR CORRECT CURRENT LIST OF LIGHTS PRIOR TO DEPARTURE._x001C_ SOLAS 74(AMD) V/20.
Condition: Unknown
Due 17 July 2001
Resolved 6 August 2001
Lifesaving
Issued 11 June 2001
Resolved
PROPERLY ATTACH PORT SIDE BUOY LIGHT BRACKET TO ENSURE PROPER OPERATION. SOLAS 60 III- 21 (f). PRIOR TO NEXT U.S. PORT.
Condition: Unknown
Due 13 July 2001
Resolved 13 July 2001
Lifesaving
Issued 11 June 2001
Resolved
REMOVE AND PROPERLY STOW EXTRA GEAR AND EQUIPMENT FROM HOSPITAL SPACE AND EMERGENCY GENERATOR ROOM. ILO 147. PRIOR TO NEXT U.S. PORT.
Condition: Unknown
Due 13 July 2001
Resolved 13 July 2001
Electrical
Issued 11 June 2001
Resolved
ELECTRICAL PANEL IN EMERGENCY GENERATOR ROOM- PANEL DOOR NOT PROPERLY SECURED. SOLAS 60 II-27 (a) (ii). PRIOR TO NEXT U.S. PORT.
Condition: Unknown
Due 13 July 2001
Resolved 13 July 2001
Documentation
Issued 15 March 1999
Resolved
Provide a first engineering officer IAW the safe manning certificate prior to 16MAR99.
Condition: Unknown
Due 16 March 1999
Resolved 16 March 1999
Navigation
Issued 17 October 1998
Resolved
Add warning statement to maneuvering fact sheet._x001C_ 33 C.F.R. 164.35(g)
Condition: Unknown
Due 17 March 1999
Resolved 17 March 1999
Construction/Loadline
Issued 17 October 1998
Resolved
Effect permanent repair to 4" crack, stbd stern area near compressor room.
Condition: Unknown
Due 17 March 1999
Resolved 17 March 1999
Navigation
Issued 17 October 1998
Resolved
Repair recording device for echo depth sounder. _x001C_ 33 C.F.R. 164.34(i)
Condition: Unknown
Due 17 March 1999
Resolved 17 March 1999