Records from 2006 to 2026. Most recent: inspection, 25 February 2026.
Documentation record
Registered dimensions (L × B × D)297.5 ft × 54.0 ft × 12.0 ft
Registered tonnagegross 1,619 / net 1,619
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderJEFFBOAT LLC · JEFFERSONVILLE, IN, UNITED STATES · built 2006
Hull materialSteel
PropulsionNot recorded
Hull shapeBox
Hull configurationMonohull
Hailing portHOUSTON, TX
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 7 February 2026 · expires 31 March 2027
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it1619 - Simplified, Gross Ton
1619 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 37
25 February 2026
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 8322910
10 March 2025
Examination of Repairs · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8091036
30 January 2024
Periodic Inspection · Administrative Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7857832
13 May 2022
Type not recorded
No type recorded · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 7452237
22 November 2021
Drydock Exam · Administrative Inspection · Examination of Repairs · Cargo Tank Internal · MTSA Verification · Internal Structural Exam · COI Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7355668
15 September 2020
Examination of Repairs · Annual Inspection · Administrative Inspection · MTSA Verification
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7058462
12 August 2020
Administrative Inspection · Deficiency Check · Examination of Repairs
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 7030975
1 April 2020
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6933930
14 January 2020
Administrative Inspection · Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 6886518
16 November 2019
Administrative Inspection · Damage Survey
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6858224
16 November 2019
Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6859954
3 August 2019
Bulk Liquid Transfer Monitor
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6771154
29 July 2019
Deficiency Check · Examination of Repairs
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6765733
5 June 2019
Type not recorded
No type recorded · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 6704382
5 June 2019
Damage Survey · Administrative Inspection
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 6704837
24 January 2019
Periodic Inspection · MTSA Verification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6612323
9 January 2019
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6608083
27 November 2017
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6310940
17 October 2016
COI Inspection · MTSA Verification · Internal Structural Exam · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6023930
3 May 2016
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5868303
11 February 2016
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5816700
13 January 2016
Examination of Repairs · Administrative Inspection · MTSA Verification · Annual Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5796696
20 January 2015
Examination of Repairs · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5054170
17 January 2014
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4787347
15 January 2014
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4787332
10 January 2014
MTSA Verification · Periodic Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4786320
12 March 2012
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4261879
14 November 2011
Examination of Repairs · Drydock Exam · COI Inspection · Damage Survey · Internal Structural Exam · Cargo Tank Internal · Administrative Inspection
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 4188565
10 February 2011
Annual Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 3942717
12 February 2010
MTSA Verification · Periodic Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3679270
15 January 2009
Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 3412111
4 February 2008
MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3140200
7 November 2007
Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3095292
7 November 2007
Damage Survey
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3095494
14 November 2006
Internal Structural Exam · Hull Examination · Initial Certification · Cargo Tank Internal
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 2820334
25 October 2006
MTSA Verification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2808077
1 September 2006
Security Plan Amendment Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 2765771
09 - Working and Living Conditions › 092 - Working Conditions › Structural features (ship)
Issued 16 November 2019
Resolved
Scantlings, material, and workmanship shall be at least equivalent to the requirements of the American Bureau of Shipping or other recognized classification society. Vessel has a starboard aft deck button with an 18" diameter liberated from the deck. Repair/replace button to the satisfaction of attending OCMI Marine Inspectors once vessel reaches current voyage destination New Orleans, LA and prior to next voyage.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 December 2019
Resolved 12 August 2020
Resolution: Recevied objective evidence the stern button was repaired.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 5 June 2019
Resolved
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 July 2019
Resolved 1 August 2019
Resolution: Exam of repair completed and satisfactory air testing of bow rake flooring and #1 void bulkhead seams completed to Marine Inspector satisfaction.
Engineering › Fuel Oil Service System › Hose
Issued 25 October 2016
Resolved
Outer covering of diesel fuel supply and return piping for diesel pump engine torn. Covering required to maintain J1942 approval rating (46 CFR 56.60-25(b)). Hoses required to be replaced prior to off loading cargo with associated cargo pump.
Action required: 705 - Other - as specified
Due 27 October 2016
Resolved 27 October 2016
Resolution: New approved hoses installed.
Electrical › Electric Generation Source (service) › Generator Cable
Issued 11 February 2016
Resolved
John Deere enigine/wiring harness fails to meet class 1 division 1 requirements as per 46 CFR 111.105-31, equipment falls within hazardous zone.
Action required: 705 - Other - as specified
Due 11 February 2016
Resolved 3 May 2016
Resolution: Changed cargo authority for vessel to allow for carriage of Grade E cargos only.
Construction/Loadline › Markings › Vessel Name/Home Port
Issued 10 January 2014
Resolved
Barge was purchased by Genesis Marine (GM) from Florida Marine Transport (FMT) and the name of the barge was changed from the FMT 5008 to the GM 5008, however the name marked on the barge still reads FMT 5008. Rename barge with correct name (GM 5008).
Condition: Invalid
Action required: 705 - Other - as specified
Due 10 February 2014
Resolved 17 January 2014
Resolution: Received photo confirmation via email from Egan Marine showing the correct barge name stenciled on the barge. All sat.
Deck/Cargo › Holds/Tanks › Valve, Pressure Vacuum Relief
Issued 10 January 2014
Resolved
Replace or adjust cargo tank ERL 2.5" Equate P/V valves and provide proof that they open within the specified pressure range on the type approval certificate (up to 120%) IAW 46 CFR 162.017
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 February 2014
Resolved 17 January 2014
Resolution: Barge reps at Egan Marine replaced all six ERL P/Vs valves with P/V valves manufactured by Morrison Co, part # 153B and provided testing certs from Pentair Controls. All sat.
Deck/Cargo › Cargo Heating › General
Issued 10 January 2014
Resolved
Provide copy of approval letter from MSC for thermal fluid heater. Letter should include copy of the procedures submitted to MSC for testing the safeties on the thermal fluid heater.
Action required: 705 - Other - as specified
Due 10 February 2014
Resolved 15 January 2014
Resolution: Company provided copy of letter. Verified barge hull number fell within the hull number range specified on the approval letter. Verified testing instructions matched the instructions used during the tests conducted on 10 Jan 2014.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Piping
Issued 10 January 2014
Resolved
Conduct/provide proof of required annual testing of cargo piping, cargo pump relief valve and pressure gauge. Testing paper work on board listed the last test date as 1/2013. Paperwork did not specify the actual day of the test, so requiring the barge to have the piping tested by the end of the month 31 Jan 2014. Also informed barge rep that testing paper work must indicate the day of the test.
Action required: 705 - Other - as specified
Due 31 January 2014
Resolved 17 January 2014
Resolution: Company provided test certs for new installed cargo pump relief valve, installed a new gauge and provided paperwork for cargo piping pressure test. Test certs uploaded to MISLE docs, all sat.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Closure Devices
Issued 10 January 2014
Resolved
Replace/repair missing position indicators on cargo piping valves.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 10 February 2014
Resolved 15 January 2014
Resolution: Company installed new valve position indicators on two valves that were missing them. All sat.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Pump
Issued 14 November 2006
Resolved
Vessel owners are to prove that cargo pump engine units are in complete compliance with 46 CFR 111.105-31(l)
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 1 August 2007
Resolved 23 November 2011
Resolution: Pump engines were moved out of the 10 foot hazardous zone radius.