Inspection history · 59
15 April 2026
Deficiency Check · Administrative Inspection · COI Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 8349909
14 October 2025
Deficiency Check
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 8251818
14 October 2025
Type not recorded
No type recorded · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 8253194
26 September 2025
COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 8241698
20 August 2025
Bulk Liquid Transfer Monitor
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 8214792
13 September 2024
Damage Survey
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 8002340
13 September 2024
Type not recorded
No type recorded · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 8085310
10 August 2024
Type not recorded
No type recorded · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 7986129
3 January 2023
Administrative Inspection
Administrative · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 7615840
1 February 2022
Administrative Inspection
Administrative · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 7389130
26 April 2021
Administrative Inspection
Administrative · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 7182980
6 November 2020
Administrative Inspection
Administrative · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 7090973
16 September 2020
MTSA Verification · Initial Certification
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 7059231
27 April 2020
TPO Audit · Administrative Inspection
Administrative · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 6946101
19 April 2017
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6128573
19 September 2016
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6004097
18 September 2016
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6009551
25 February 2016
MTSA Verification · Industry Initiated Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5826512
25 August 2015
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5737968
7 October 2014
Type not recorded
No type recorded · Station Lake Charles · USCG Heartland District (CGD-H) · Activity 5003315
22 July 2014
Damage Survey
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 4930410
4 March 2014
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4887617
28 February 2013
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4541597
30 October 2012
MTSA Verification · Industry Initiated Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4476312
25 July 2012
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 4390291
14 February 2012
Damage Survey
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4245187
14 February 2012
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4251827
18 May 2011
Type not recorded
No type recorded · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 4015377
2 March 2010
Industry Initiated Exam · MTSA Verification · DAPI Audit
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3693807
26 February 2009
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3424448
23 January 2009
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3648852
9 December 2008
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3376624
8 December 2008
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3380503
24 May 2006
MTSA Verification · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2657632
9 October 2005
Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 2528782
11 May 2004
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2087465
2 March 2004
Annual Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2016469
24 December 2003
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1990866
14 April 2003
Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 1986860
12 April 2003
Security Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1772660
12 December 2002
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1717931
12 December 2002
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1718066
7 November 2001
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 127745
27 October 2000
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 146464
4 May 1999
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 428440
11 March 1999
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 94492
29 January 1999
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 134313
23 November 1998
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 422943
8 November 1998
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 65606
9 September 1997
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 141590
10 March 1997
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 57861
10 March 1997
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 151416
2 February 1995
Type not recorded
No type recorded · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 374902
19 December 1994
Type not recorded
No type recorded · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 373581
27 September 1994
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 370886
25 May 1994
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 459543
6 May 1994
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 152727
19 September 1993
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 84850
7 October 1988
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 326183
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 21 April 2026
Resolved
Means must be provided for stopping each fan in a ventilation system serving machinery spaces and for closing, in case of fire, each doorway, ventilator, and annular space around funnels and other openings into such spaces. The front side of the exhaust stack house has an opening to the engine room that does not have any means to close off the engine room space. Install a ventilation closer.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 May 2026
Resolved 23 April 2026
Resolution: The deficiency was cleared to the satisfaction of a USCG Marine Inspector.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 15 April 2026
Resolved
Any vessel of at least 5 net tons which engages in coastwise trade must have a Certificate of Documentation bearing a valid endorsement appropriate for the activity in which engaged. The vessel was purchased during the DHS government shutdown, company submitted their COD application to NVDC, the NVDC is currently closed and has not updated the vessels COD with the new owner information. Once the vessl has received its COD, provide a copy to [email withheld].
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 May 2026
Resolved 29 April 2026
Resolution: The vessel received its new COD.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 14 October 2025
Resolved
Machinery and Electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. Vessel experienced starboard main engine failure during start up. Repair main engine to operational status.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 28 October 2025
Resolved 26 November 2025
Resolution: Witnessed satisfactory operation of the starboard main engine.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 13 September 2024
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons on board under normal and emergency conditions. Vessel experienced loss of propulsion from the starboard propulsion shaft. Starboard shaft was found broken. Repair starboard propulsion shaft to the satisfaction of TPO.
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 October 2024
Resolved 27 September 2024
Resolution: Recieved Corrective Action Report from TPO
Documentation
Issued 19 December 1994
Resolved
RADIOTELEPHONE LOG NOT MAINTAINED AS REQUIRED BY 47 C.F.R. 60.405 AND 60.409(e)(f).
Condition: Unknown
Due 2 February 1995
Resolved 2 February 1995
Deck/Cargo
Issued 19 December 1994
Resolved
THERE WAS NO FUEL OIL DISCHARGE CONTAINMENT FOR OIL TRANSFER TO/FROM THE VESSEL.
Condition: Unknown
Due 2 February 1995
Resolved 2 February 1995
Documentation
Issued 19 December 1994
Resolved
NO RECORDS CONTAINING REQUIRED INFORMATION HAS BEEN KEPT.
Condition: Unknown
Due 2 February 1995
Resolved 2 February 1995
Deck/Cargo
Issued 19 December 1994
Resolved
OIL TRANSFER HOSE DOES NOT MEET REQUIREMENTS OF 33 C.F.R. 154.500.
Condition: Unknown
Due 2 February 1995
Resolved 2 February 1995
Documentation
Issued 19 December 1994
Resolved
OIL TRANSFER PROCEDURES WERE NOT AVAILABLE.
Condition: Unknown
Due 2 February 1995
Resolved 2 February 1995