Records from 1993 to 2023. Most recent: inspection, 11 October 2023.
Inspection history · 53
11 October 2023
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7807016
13 May 2023
TPO Audit
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7739854
5 December 2022
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7604560
11 February 2022
Deficiency Check · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7394836
30 July 2020
Administrative Inspection · Deficiency Check · Initial Certification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7081500
21 April 2017
Administration · Industry Initiated Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6128191
16 November 2016
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6042528
7 September 2012
DAPI Audit · MTSA Verification · Industry Initiated Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4437568
13 July 2008
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3269918
28 August 2006
Administrative Inspection
Administrative · Marine Safety Center (MSC) · Activity 2762124
23 June 2005
Type not recorded
No type recorded · Station New Orleans · USCG Heartland District (CGD-H) · Activity 2400624
21 June 2005
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2398651
21 June 2005
Type not recorded
No type recorded · Station New Orleans · USCG Heartland District (CGD-H) · Activity 2399532
31 May 2005
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2383542
7 June 2004
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2108140
29 July 2003
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 1862039
10 November 2002
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 1703686
8 November 2002
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1707755
12 October 2002
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 1693310
29 May 2002
Type not recorded
No type recorded · Station New Orleans · USCG Heartland District (CGD-H) · Activity 1637167
5 June 2000
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 165744
4 February 1999
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 50035
4 February 1999
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 76365
11 October 1998
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 167263
6 December 1997
Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 51702
6 December 1997
Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 225516
6 December 1997
Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 410744
28 November 1997
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 34047
24 July 1997
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 34897
3 April 1997
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 36985
22 January 1997
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 167285
21 December 1996
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 121573
24 November 1996
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 155237
19 September 1996
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 25654
9 August 1996
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 394188
2 August 1996
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 109666
18 July 1996
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 83679
6 January 1996
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 110920
24 December 1995
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 156662
4 November 1995
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 82491
19 October 1995
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 3199
6 August 1995
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 111357
30 March 1995
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 752196
28 March 1995
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 196915
22 December 1994
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 79433
3 November 1994
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 677333
28 October 1994
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 115149
4 October 1994
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 54695
20 September 1994
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 214289
24 July 1994
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 68046
22 July 1994
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 31538
13 May 1994
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 157373
5 September 1993
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 134129
07 - Fire Safety › N/A - No Subsystem › Evaluation of crew performance (fire drills)
Issued 14 March 2022
Resolved
Fire drills are required to be performed onboard vessel monthly by all crew members. Crew members were not performing fire drills onboard vessel as frequently as required. Vessel operator to provide plan to correct this and a completed CAR.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 March 2022
Resolved 1 April 2022
Resolution: Provided CAR for how to conduct drills including new crew members.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 14 March 2022
Resolved
Electrical systems and equipment must function properly and system failures and fire and shock hazards. Electrical pannelboard below operating station console wouldn't close. Operator must fixed panelboard door.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 1 April 2022
Resolution: Sent a picture of the door being able to close
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 14 March 2022
Resolved
The master must ensure that all life saving equipment is properly maintained and ready for use at all times. The stbd 2nd deck and stbd 3rd deck lifebuoys had deteriated retro tape. Master must ensure the retro tape is properly replaced.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 March 2022
Resolved 1 April 2022
Resolution: Sent pictures of the replaced reflective tape
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 14 March 2022
Resolved
The master of each towing vessel maintain the required navigational safety equipment in a fully-functioning, operational condition. Master didn't know how to operate/update AIS. Master needs to demonstrate proficiency in operating the specific model of AIS equipment onboard.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 March 2022
Resolved 25 May 2022
Resolution: Sent instructions for AIS training
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 14 March 2022
Resolved
Machinery and electrical systems must be designed and maintained to provide for the safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. The pressure guage for the port side air receiver had too small of a range (guage tops out at 200psi, same MAWP as the tank and below the allowable range of the relief valve). Vessel to too install a pressure guage with a range 1.2-2x the setting of the relief valve (relief valve was set to 190psi).
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 March 2022
Resolved 1 April 2022
Resolution: Sent pitcures of the new gauge
14 - Pollution Prevention › 141 - MARPOL Annex I › Control of discharge
Issued 14 March 2022
Resolved
Each towing vessel must be operated in compliance with applicable pollution prevention laws and regulations. The stuffing boxes below both dripless shaft seals had oil in them and electric bilge pumps set to automatically pump overboard, which could create an unlawful pollution incident. Stuffing boxes should be cleaned and the automatic bilge pumps removed and the discharge piping secured.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 March 2022
Resolved 1 April 2022
Resolution: Pictures provided of clean bilge.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 14 March 2022
Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and electrical hazards. The windings & protective grates for both steering pump motors had a buildup of oily grime. Vessel owner to have the windings and protective grates cleaned.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 March 2022
Resolved 1 April 2022
Resolution: Sent pictures of clean windings
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 14 March 2022
Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and electrical hazards. The windings & protective grates for both ships service diesel generators had a buildup of oily grime. Vessel owner to have the windings and protective grates cleaned.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 March 2022
Resolved 1 April 2022
Resolution: Sent pictures of windings cleaned
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 14 March 2022
Resolved
The fire detection system and alarm panel must be tested monthly. Fire detection panel wasn't tested monthly. Vessel operator to provide plan to correct this and a completed CAR.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 March 2022
Resolved 1 April 2022
Resolution: Sent logs of monthly checks.
09 - Working and Living Conditions › 091 - Living Conditions › Water, pipes, tanks
Issued 14 March 2022
Resolved
The operator must impliment procedures to to identify and mitigate health and safety hazards onboard. The vessel's H&S manual lists the tap water onboard as not being safe for human consumption. Labels need to be put above the sinks indicating tap water isn't for human consumption as per vessel's H&S manual.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 March 2022
Resolved 25 May 2022
Resolution: Sent pictures of the labels
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 14 March 2022
Resolved
Machinery and electrical systems must be designed and maintained to provide for the safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. Flexible non-metallic grease line hose for stbd rudder arm was kinked and damaged. Operator needs to replace the damaged flexible non-metallic hose.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 March 2022
Resolved 1 April 2022
Resolution: Sent picture of the new hose
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 8 January 2021
Resolved
A towing vessel must carry a combination of day and night visual distress signals indicated in Table 141.370: Vessel did not have any flares on board.
Action required: 10 - Deficiency Rectified
Resolved 8 January 2021
Resolution: Vessel had them delievered while inspector was on board.
Engineering
Issued 6 December 1997
Resolved
PLACE SAFETY GUARDS ON FRONT OF MAIN ENGINES. (MISSING)
Condition: Unknown
Due 8 January 1998
Resolved 8 January 1998