Records from 1996 to 2026. Most recent: inspection, 8 June 2026.
Documentation record
Registered dimensions (L × B × D)104.2 ft × 34.0 ft × 13.5 ft
Registered tonnagegross 192 / net 131
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderOFFSHORE SHIPBUILDING INC · PALATKA, FL, UNITED STATES · built 1986
Hull materialSteel
PropulsionDiesel
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNEW YORK, NY
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 23 July 2026 · expires 31 August 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it192 - Regulatory (Subpart C or D), Gross Ton
131 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 23
8 June 2026
Excursion Permit
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 8394861
29 April 2026
COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8326940
25 June 2025
Administrative Inspection
Administrative · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8167102
12 March 2024
Administrative Inspection
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7877608
8 June 2023
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7714239
29 June 2021
Initial Certification
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7215157
22 June 2020
Administrative Inspection
Administrative · Commandant (CG-CVC) · Activity 6984054
27 October 2017
DAPI Audit
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6297536
27 October 2017
Industry Initiated Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6343668
15 September 2014
Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 4984081
30 July 2014
DAPI Audit · Industry Initiated Exam · MTSA Verification
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 4939814
11 August 2011
MTSA Verification · Industry Initiated Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 4112123
18 December 2007
Annual Inspection
Physical examination · Station Philadelphia · USCG East District (CGD-E) · Activity 3119802
11 January 2007
Type not recorded
No type recorded · USCGC CAPSTAN (WYTL 65601) · USCG East District (CGD-E) · Activity 2973417
30 November 2006
MTSA Verification
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2832079
6 January 2006
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2564811
1 February 2005
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2285120
30 December 2003
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1973073
19 September 2000
Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 131769
24 July 1998
Excursion Permit
Administrative · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 795455
16 July 1997
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 782885
15 July 1997
MARPOL Annex V Examination · Uninspected Towing Vessel
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1115548
29 May 1996
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1371439
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 29 June 2021
Resolved
Guard rails or bulwarks shall be fitted around all exposed decks. The vessel’s aft freeboard deck (above the z-drive space) is missing bulwarks or guard rails to prevent the falling overboard of the crew. Upon expanding the inspection into the ABS survey for Load Lines (Form LL-11-D) it was found that the vessel is missing the required stanchions and chains at frame 62 required for that purpose.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 2 August 2021
Resolution: The required stanchions and chains at Frame 62 per the Survey for Load Lines LL-11-D were installed and verified satisfactorily by the
attending Surveyor.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Cargo & other hatchways
Issued 29 June 2021
Resolved
The master shall ensure that all hatches, doors and other openings designed to be water tight or weather tight function properly. Multiple violations including: 1) A 12" deck port cover located on the stbd aft of the vessel was severely deteriorated, siliconed in place and painted over. 2) The starboard-aft most deck hatch granting access to the steering had had a torn gasket incapable of creating a watertight boundary. 3) The deck house and port-side water tight doors failed to close as intended. Daylight was clearly visible around the knife edge seals. 4) The captain's port light dead covers was not closing properly, both port & starboard light dead covers were missing their securing bolts; and stbd dead cover was not installed on its place. 5) A bolted secured hatch located at port side aft, was found to have missing 3 of its securing bolts. 6) A hole was found on the top of the coaming at 12 o'clock position at the port side watertight door.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 2 July 2021
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 29 June 2021
Resolved
Each towing vessel must be maintained and operated to minimize fire hazards and ensure all bilges and void spaces are kept free from accumulation of combustible and flammable materials and liquids insofar as practicable. Excessive amounts of oily water was found in the Z-drive compartment and engine room bilge.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 2 July 2021
Resolution: ABS will keep track of this deficiency per TSMS guidance
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 29 June 2021
Resolved
Each space where crew may be quartered or normally employed must have at least two means of escape. The means of escape leading from the operating station towards the open deck behind the operating station was being blocked by a resting chair.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 2 July 2021
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 29 June 2021
Resolved
Storage areas are kept free from accumulation of combustible and flammable materials insofar as practicable. Combustible materials were found generalized in several areas of the vessel, such as: engine room, accommodation spaces, forward anchor pump room, space located above the engine room.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 July 2021
Resolved 2 July 2021
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 29 June 2021
Resolved
A vessel operation in Sea Area A1 under its Rescue 21 Distress System coverage must have a Class A VHF-DSC radio properly connected to a GPS receiver or have an integral GPS radio. VHF radio must display GPS coordinates and have the assigned MMSI number in the FCC Radio Telephony Certificate entered.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 July 2021
Resolved 2 July 2021
Resolution: ABS will keep track of this deficiency per TSMS guidance
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 29 June 2021
Resolved
Every vessel must have a detailed inspection of the radio installation by an FCC-licensed technician in accordance with 80.59 once every five years. The current certificate indicates an inspection and expiration are both August 2020 as the expiration.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 July 2021
Resolved 2 July 2021
Resolution: ABS will keep track of this deficiency per TSMS guidance
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 29 June 2021
Resolved
The master must ensure that all lifesaving equipment is properly maintained and ready for use at all times. The port side lifebuoy and grab line were found wasted and require replacement.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 July 2021
Resolved 2 July 2021
Resolution: ABS will keep track of this deficiency per TSMS guidance
Lifesaving
Issued 15 July 1997
Resolved
Provide the vessel with (1) cat.1 eprib, presently not on board the vessel._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 16 August 1997
Resolved 21 July 1997