MAURY USCG vessel records
← All vessels

FDH 35 1

Built
2003
Last inspected
31 October 2024
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.

Inspection record

Last inspected 31 October 2024
…with no type recorded15
Operational controls None recorded without a removal date
Years with a record 19 calendar years (2003–2024)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

652551
Flag
UNITED STATES
Maury page id
psix-652551

Documentation record

Registered dimensions (L × B × D)227.2 ft × 60.0 ft × 24.0 ft
Registered tonnagegross 2,496 / net 1,612
ITC dimensions (L × B × D)227.2 ft × 60.0 ft × 24.0 ft
ITC tonnagegross 2,496 / net 1,612
BuilderZIDELL MARINE CORPORATION · PORTLAND, OR, UNITED STATES · built 2003
Hull materialSteel
PropulsionUNSPECIFIED
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portRICHMOND, CA
Endorsements, as the file codes themcw_un, reg
DocumentationValid · issued 18 December 2025 · expires 31 January 2027
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it4999 - Dead Weight, Gross Ton
2496 - Convention (Subpart B), Gross Ton
1612 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 48 inspections, each with its date, unit and type; 30 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; 7 other vessels inspected with it; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 7

Inspection history · 48

31 October 2024 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8027638
3 August 2023 Internal Structural Exam · Drydock Exam · Cargo Tank Internal · Hull Examination · COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7791140
23 January 2023 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7631274
13 December 2021 Periodic Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7367099
5 November 2021 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7346238
24 August 2021 Internal Structural Exam · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7186321
16 November 2020 Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7096542
16 January 2020 Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6890383
26 November 2018 Deficiency Check · COI Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6588608
24 October 2018 Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6567191
20 August 2018 Damage Survey · Deficiency Check · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6518282
14 April 2018 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6406103
15 November 2017 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6322490
25 October 2016 Administrative Inspection · Annual Inspection · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6030877
9 December 2015 Periodic Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5778325
15 December 2014 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5039623
7 August 2014 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4960817
2 October 2013 Drydock Exam · Internal Structural Exam · COI Inspection · MTSA Verification
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4727947
17 October 2012 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4466407
6 June 2012 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4335797
12 April 2012 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4286076
12 January 2012 Plan Review (Other than "T")
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4227353
27 December 2011 Examination of Repairs · Damage Survey
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4214995
26 December 2011 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4253652
14 September 2011 Periodic Inspection · Internal Structural Exam · MTSA Verification
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4142932
10 December 2010 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3908498
26 October 2010 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3865339
10 February 2010 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3680510
25 January 2010 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3684688
31 October 2008 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3355199
21 October 2008 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3350066
14 October 2008 Hull Examination · COI Inspection · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3338124
29 October 2007 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3089322
6 November 2006 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2815611
12 September 2006 Internal Structural Exam · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2776245
13 May 2006 Damage Survey
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2648557
13 May 2006 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2650084
11 January 2006 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2563407
21 April 2005 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2318756
21 April 2005 MTSA Verification
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2318764
18 April 2005 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2336717
18 March 2005 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2314888
12 January 2005 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2307220
5 August 2004 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2167520
7 April 2004 Administrative Inspection
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2039540
12 January 2004 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1983259
31 October 2003 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1942133
24 October 2003 Initial Certification · Hull Examination · Internal Structural Exam
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1929009

Deficiency record · 30

06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 13 December 2021 Resolved
Periodic inspection. Your vessel must undergo a periodic inspection within 3 months before or after the second or third anniversary of the date of your vessel's COI. The scope of the periodic inspection is the same as that for the inspection for certification as specified in 31.10-15(b). The inspection for certification shall include an inspection of machinery and equipment. Both prime movers were not in a condition to witness operational tests and shutdowns.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 13 December 2021
Resolved 20 December 2021
Resolution: Operational tests and shutdowns of prime movers inspected satisfactorily.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 16 November 2020 Resolved
All tank vessels are subject to the regulatoins in parts 50 to 63 of Subchapter F. Exhaust manifold heat shielding missing on port and stbd cargo pump engine. 31.30-1 56.95(b)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 December 2020
Resolved 26 February 2021
Resolution: Photos submitted 18 NOV 2020.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 26 November 2018 Resolved
Cargo tanks in which Grade A, B, or C liquids are to be transported shall be fitted with either individual pessure-vacuum relief valves or shall be fitted with a venting system consisting of branch vent lines. Inboard P/V relief valve was seized on the vacuum side. Ensure proper operation of P/V relief valve.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 26 November 2018
Resolved 26 November 2018
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 26 November 2018 Resolved
Each ungrounded system must be provided with a suitably sensitive ground detection system located at the respective switchboard which provides continuous indication of circuit status to ground with a provision to momentarily remove the indicating device from the reference ground. The ground fault indicating lamps were burnt out.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 December 2018
Resolved 18 December 2018
Resolution: New bulbs were installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 26 November 2018 Resolved
There must be ground detection for each power system that is isolated from the ship's service power by transformers. Vessel does not have ground detection at the transformer.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 December 2018
Resolved 24 September 2019
Resolution: Ground detection installed.
02 - Structural Conditions › N/A - No Subsystem › Spaces in cargo areas
Issued 20 August 2018 Resolved
Conduct permanent repairs to pinhole weld leak in #4P fwd, centerline blkhd during next drydock.
Action required: 705 - Other - as specified
Due 31 October 2018
Resolved 16 January 2020
Resolution: Vessel representative provided maintenance evidence of repair completion.
Construction/Loadline › Hull › Hull Plating
Issued 27 December 2011 Resolved
Provide a repair plan for the damaged section of the portside bow rake.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 January 2012
Resolution: Received details from shipyard for repairs made.
Deck/Cargo › Holds/Tanks › Hatch
Issued 27 December 2011 Resolved
Provide access to port wing tanks as necessary to survey the damage.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 December 2011
Resolution: The port # 1 wing tank was thoroughly inspected and no other damage was apparent.
Construction/Loadline › Hull › Hull Plating
Issued 27 December 2011 Resolved
Make permanent repairs to the portside bow rake prior to cargo operations.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 January 2012
Resolution: Crop and renew hull plating IWO damage areas marked out by CG inspectors and ABS rep. Crop and renew all bottom longitudinals and deep web framing IWO of damaged areas marked out by CG inspectors and ABS rep. All repairs were made and 835 cleared.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Pump
Issued 27 December 2011 Resolved
Vessel is granted a onetime cargo operation prior to making repairs, to offload any remaining cargo onboard.
Action required: 705 - Other - as specified
Resolved 12 January 2012
Deck/Cargo › Cargo Stowage › General
Issued 14 September 2011 Resolved
Issued CG-835: Identify source of cargo leaks found in the #4 double bottom, on the fwd bulkhead, and fractured weld next to ladder on cargo tank wall, IAW 46 CFR 31.10-21(c).
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 September 2011
Resolution: ALOT of back gouging and re-welding on either side of suspected weld fractures. Pressed up wing voids (soap solution), air lance and finally dye penetrate. No leaks from any site. (ABS - class present during the whole evolution).
Deck/Cargo › Holds/Tanks › Independent Tank
Issued 14 September 2011 Resolved
Issued CG-835: Make proper repairs to leaking hydraulic line from day tank (hose clamps).
Due 14 October 2011
Resolved 17 September 2011
Resolution: Replaced hose and clamps.
Documentation › Certificates/Documents › Stability Letter
Issued 12 October 2010 Resolved
Provide on board the stability letter dated 11 March 2004.
Due 26 October 2010
Resolved 26 October 2010
Construction/Loadline › Hull › Double Hull
Issued 13 May 2006 Resolved
Make #5 starboard void available for inspection by a Coast Guard Marine Inspector prior to conducting cargo operations with the barge.
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 May 2006
Resolved 19 May 2006
Fire Fighting › Semiportable Chemical-Foam Fire Extinguishers › Number
Issued 11 January 2006 Resolved
Provide one B-V semi-portable extinguisher in the cargo area IAW 46 CFR Table 34.10(a). This requirement must be completed prior to transiting with persons onboard.
Due 11 February 2006
Resolved 19 May 2006
Lifesaving › Lifefloat › Quantity
Issued 11 January 2006 Resolved
Provide one six person life float IAW Title 46 Subchapter W and local policy. This requirement must be completed prior to transiting with persons onboard.
Due 11 February 2006
Resolved 19 May 2006
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Piping
Issued 21 March 2005 Resolved
Properly secure fuel piping on starboard cargo pump engine.
Due 21 April 2005
Resolved 21 April 2005
Engineering › Compressed Air System (control) › Receiver/Bottle
Issued 21 March 2005 Resolved
Properly secure air receiver in cargo pump engine shack.
Due 21 April 2005
Resolved 1 April 2005
Resolution: Removed requirement and issued a different requirement on 01APR05 that required the operator to remove the air receiver completely.
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 21 March 2005 Resolved
Properly blank off the unused circuit breaker (#6) on the main panel in cargo pump engine shack.
Due 21 April 2005
Resolved 21 April 2005
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Piping
Issued 21 March 2005 Resolved
Provide proof of annual calibration of all pressure gauges on cargo lines and pumps IAW 46CFR35.35-70.
Due 21 April 2005
Resolved 21 April 2005
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 21 March 2005 Resolved
Provide 2 Type-I lifejackets IAW 46CFR199.620. Must be completed prior to getting underway with persons onboard.
Due 21 April 2005
Resolved 21 March 2005
Resolution: Operator provide receipt and written attestation.
Deck/Cargo › Cargo Stowage › General
Issued 21 March 2005 Resolved
Properly secure drum on stern. Must be completed prior to getting underway with persons onboard.
Due 21 April 2005
Resolved 21 March 2005
Resolution: Operator provided written attestation.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Flame Screens
Issued 21 March 2005 Resolved
Clean flame screens on vent on common vapor header.
Due 21 April 2005
Resolved 21 March 2005
Resolution: Operator corrected on the spot.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 21 March 2005 Resolved
Renew batteries in waterlight.
Due 21 April 2005
Resolved 21 March 2005
Resolution: Operator corrected on the spot.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 21 March 2005 Resolved
Stencil name of vessel and port on lifebuoy.
Due 21 April 2005
Resolved 21 March 2005
Resolution: Operator corrected on the spot.
Engineering › Diesel Engine (auxiliary) › Valve
Issued 21 March 2005 Resolved
Prove proper operation of emergency fuel shut-off valve for the starboard cargo pump engine.
Due 21 April 2005
Resolved 21 March 2005
Resolution: Operator corrected on the spot.
Operations/Management › Cargo Transfer/Lightering › Making a Connection
Issued 18 March 2005 Resolved
Vessel is permitted to offload all cargo at a port within the confines of San Francisco Bay and its tributaries at the first available opportunity. Following offload, vessel is restricted from conducting any cargo operations until a satisfactory COI inspection is completed.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 April 2005
Resolution: Conducted a satisfactory COI inspection.
Engineering › Compressed Air System (control) › Receiver/Bottle
Issued 18 March 2005 Resolved
Remove the Husky 5 HP 26 gallon vertical compressor from the tank barge. The barge is restricted from operating the compressor at any time until removal from the barge. All air pressure shall be relieved from the pressure vessel and its electrical source properly disconnected. Cite: 46 CFR 54.01-5(c)(4)
Due 1 May 2005
Resolved 21 April 2005
Operations/Management › Pollution
Issued 24 October 2003 Resolved
Provide valid Vessel Response Plan and Shipboard Oil Pollution Emergency Plan. This item is to be completed prior to loading of cargo. LEGACY COMPONENT DESC: Vessel Response Plan
Condition: Unknown
Due 15 November 2003
Resolved 29 October 2003
Deck/Cargo › Holds/Tanks
Issued 24 October 2003 Resolved
Repair and demonstrate operation of High Level and Overfill alarms. This item is to be completed prior to loading of cargo LEGACY COMPONENT DESC: Tank Level Monitoring Device
Condition: Improper Installation
Due 15 November 2003
Resolved 31 October 2003
Resolution: Alarms tested sat.

Ownership record