MAURY USCG vessel records
← All vessels

FDH 35 2

FDH 35 2 is a 2004 tank barge. The Coast Guard has recorded 45 inspections since 2004, most recently in February 2026, along with 30 deficiencies and 6 casualty investigations between 2004 and 2011.

Records from 2004 to 2026. Most recent: inspection, 20 February 2026.

Built
2004
Last inspected
20 February 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.

Inspection record

Last inspected 20 February 2026
…with no type recorded7
Operational controls None recorded without a removal date
Years with a record 23 calendar years (2004–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

667902
Flag
UNITED STATES
Maury page id
psix-667902

Documentation record

Registered dimensions (L × B × D)227.2 ft × 60.0 ft × 24.0 ft
Registered tonnagegross 2,496 / net 1,612
ITC dimensions (L × B × D)227.2 ft × 60.0 ft × 24.0 ft
ITC tonnagegross 2,496 / net 1,612
BuilderZIDELL MARINE CORPORATION · PORTLAND, OR, UNITED STATES · built 2004
Hull materialSteel
PropulsionUNSPECIFIED
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portRICHMOND, CA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 18 December 2025 · expires 31 January 2027
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it2496 - Convention (Subpart B), Gross Ton
1612 - Convention (Subpart B), Net Ton
4999 - Dead Weight, Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 8

Inspection history · 45

20 February 2026 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8312090
19 February 2025 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8084427
12 January 2024 Drydock Exam · Cargo Tank Internal · COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7863468
30 October 2023 Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7819034
3 February 2023 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7631257
24 February 2022 Periodic Inspection · MTSA Verification · MARPOL Annex I Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7401479
26 October 2021 Internal Structural Exam · Deficiency Check · Administrative Inspection · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7338026
8 March 2021 MARPOL Annex I Examination · MTSA Verification · Annual Inspection · MARPOL Annex VI Survey
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7139031
6 July 2020 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7000857
27 May 2020 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6962983
20 March 2020 Administrative Inspection · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6929836
20 November 2019 Administrative Inspection · Plan Review (Other than "T")
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6859488
16 January 2019 COI Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6602798
15 October 2018 Internal Structural Exam · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6561375
19 July 2018 Bulk Liquid Transfer Monitor
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6485456
20 March 2018 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6375405
15 March 2017 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6106699
18 November 2016 Internal Structural Exam · Examination of Repairs
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6045334
3 March 2016 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5826732
28 December 2015 Deficiency Check · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5819911
2 April 2015 Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5095273
10 February 2015 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5067884
30 January 2014 COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4785116
30 December 2013 Internal Structural Exam · Cargo Tank Internal · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4785080
22 March 2012 Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4270885
2 March 2012 Internal Structural Exam · MTSA Verification · Periodic Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4256649
23 February 2012 In-Service Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4256831
30 September 2011 Damage Survey
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4158433
29 September 2011 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4299581
30 August 2011 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4131860
22 April 2010 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3720825
11 March 2009 Internal Structural Exam · Drydock Exam · COI Inspection · MTSA Verification
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3426831
9 January 2009 Damage Survey
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3393092
9 January 2009 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3393962
24 March 2008 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3166069
2 November 2007 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3094240
4 April 2007 Periodic Inspection · Internal Structural Exam · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2899932
18 September 2006 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2781226
30 January 2006 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2576309
24 March 2005 MTSA Verification
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2318790
14 March 2005 Annual Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2301525
25 May 2004 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2078419
8 April 2004 Deficiency Check · In-Service Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2039262
31 March 2004 Hull Examination · Initial Certification · Internal Structural Exam
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2034965
2 February 2004 Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 2004570

Deficiency record · 30

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 16 January 2019 Resolved
There must be ground detection for each power system that is isolated from the ship's service power by transformers. Vessel does not have ground detection at the transformer.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 February 2019
Resolved 24 September 2019
Resolution: Ground detection installed.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Transfer Hose
Issued 28 December 2015 Resolved
Provide proof of maximum working pressure test of cargo hoses. 33CFR156.170
Due 22 January 2016
Resolved 22 January 2016
Electrical › Electrical Distribution System (service) › Metallic Enclosure/Frame
Issued 2 April 2015 Resolved
Provide proof that all cargo tank level indicator electrical connections are water tight as designed. Temp repair acceptable until 2017 ISE. 46CFR111.60-23
Due 4 May 2015
Resolved 28 May 2015
Electrical › Electrical Distribution System (service) › Metallic Enclosure/Frame
Issued 2 April 2015 Resolved
Make repairs to exterior wire runs passing into the machinery house. 46CFR111.105-5
Due 4 June 2015
Resolved 28 May 2015
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 2 April 2015 Resolved
Remove electrical housekeeping hazards from the tankerman house (hanging outlet, 3 outlet extension adapters) or provide load analysis detailing that outlets are not overloaded and that pigtail extensions are approved under 46CFR111.60-1 46CFR111.01-1(a)(3) 46CFR111.10-4
Due 4 May 2015
Resolved 28 May 2015
Electrical › Electrical Distribution System (service) › Metallic Enclosure/Frame
Issued 2 April 2015 Resolved
Repair cracked Tank Level Indicator support on the 4 stbd tank pipe. 46CFR111.105-5
Due 4 May 2015
Resolved 28 May 2015
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Communications
Issued 2 April 2015 Resolved
Hard pipe the cargo pump pressure gauges ensuring that non metallic flexible hose is limited to 30" or less and only where required for flexibility. 46CFR56.60-25(b)(4)
Due 4 May 2015
Resolved 28 May 2015
Deck/Cargo › Cargo Stowage › General
Issued 22 March 2012 Resolved
Oil found below #5starboard cargo tank, appears to be a failed weld in the #5 starboard cargo tank sump. Oil found below the #4 cargo tank, approx. centerline, unsure if it is from #3 or #4 (corrugated bulkhead). Oil leak (line of oil on bulkhead/previous repair) under #6 cargo tank. 46CFR30.01-10
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 March 2012
Resolution: Dye penetrate and air lance of the weld repair areas completed (#6starboard keel bulkhead - frame 33, prior repair. #5 starboard - cargo tank sump, leading edge, not bulkhead. #4/3 cargo tank sump -cord/backing plate).
Engineering › Fuel Oil Service System › Hose
Issued 2 March 2012 Resolved
"PROVIDE PROOF OF PROPER HOSE SPECIFICATION THAT MEETS SAE J-1942 ON GERERATOR SET, TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR AND CLASS (ABS)." 46 CFR 56.60-25(b).
Action required: 705 - Other - as specified
Due 3 May 2012
Resolved 2 May 2012
Resolution: Repairs: replaced all hoses on generator set with those meeting SAE J-1942 specifications as required by 46 CFR 56.60-25(b).
Construction/Loadline › Hull › Side Shell
Issued 30 September 2011 Resolved
Barge FDH 26-2 and barge FDH 35-2 had collided while docking. FDH 35-2 damage area was located port side, stern rake and was approx. 3'x4". No sharp insets.
Action required: 705 - Other - as specified
Resolved 30 September 2011
Resolution: Marine Chemist certified the stern rake. External and internal exam of damaged area and looked for transmitted energy, tripped brackets, broken welds, ect.
Deck/Cargo › Vapor Control Systems › Liquid Overfill Protection
Issued 22 April 2010 Resolved
Barge is restricted to loading grade D and E cargoes only due to inoperable cargo tank alarm system. An additional tankerman must be on board to monitor the deck when loading cargo.
Condition: Placed in Improper Service
Due 29 April 2010
Resolved 28 April 2010
Resolution: Repair technician from New Jersey completed repairs and conducted satisfactory demonstration of alarm system.
Construction/Loadline › Hull › Transverse Frame
Issued 11 March 2009 Resolved
Repair two fractures in #3 DB, fwd bulkhead IWO 1st longitudinals on each side of CVK at the cargo tanktop. Repair fracture in #6 DB, center vertical keel, one foot fwd of aft bulkhead at the cargo tanktop. Grind & reweld.
Due 12 March 2009
Resolved 12 March 2009
Engineering › Pressure Vessel › Relief Valve
Issued 11 March 2009 Resolved
Replace air receiver relief valve with appropriately set valve (currently a 160 PSI valve on a 150 PSI receiver).
Due 11 March 2009
Resolved 11 March 2009
Resolution: Swapped with a spare.
Engineering › Compressed Air System (control) › Receiver/Bottle
Issued 11 March 2009 Resolved
Open ship's service air receiver for internal examination.
Due 11 March 2009
Resolved 11 March 2009
Deck/Cargo › Holds/Tanks › Bulkhead
Issued 4 April 2007 Resolved
Found minor cargo leak coming from the bottom weld at the bulkhead between #4 and #5 Starboard cargo tanks in way of centerline. Repair as new.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 April 2007
Engineering › Compressed Air System (control) › Receiver/Bottle
Issued 1 April 2005 Resolved
Remove the Husky 5 HP 26 gallon vertical compressor from the tank barge. The barge is restricted from operating the compressor at any time until removal from the barge. All air pressure shall be relieved from the pressure vessel and its electrical source properly disconnected immediately. CITE: 46CFR54.01-5(c)(4).
Due 1 May 2005
Resolved 7 April 2005
Resolution: Operator removed it from the barge.
Deck/Cargo › Holds/Tanks › Liquid Level Gaging
Issued 18 March 2005 Resolved
Prove proper operation of the EMS MARCON high-level alarm indicators.
Due 18 April 2005
Resolved 7 April 2005
Resolution: As discussed in narrative, operated satisfactorily tested the #1 Starboard high level alarm.
Engineering › Compressed Air System (control) › Receiver/Bottle
Issued 14 March 2005 Resolved
Properly mount/secure air receiver in generator/cargo pump engine room.
Due 28 March 2005
Resolved 1 April 2005
Electrical › Electric Generation Source (service) › Generator
Issued 14 March 2005 Resolved
Prove proper operation of the automatic shutdown of the generator in the event of low lube oil pressure.
Due 28 March 2005
Resolved 14 March 2005
Resolution: Operator corrected on the spot.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Piping
Issued 14 March 2005 Resolved
Provide proof of annual calibration of all pressure gauges on cargo lines and pump IAW 46CFR35.35-70.
Due 28 March 2005
Resolved 7 April 2005
Resolution: Kept copies of calibration certificates and scanned into MISLE.
Documentation › Safety/Response Plans/Programs › SOPEP
Issued 14 March 2005 Resolved
Permanently update local contact numbers in the SOPEP and cargo transfer procedures. Operator has already provided corrected copy of cargo transfer procedures. Operator stated that this would take 3-4 weeks to correct since it would be completed by the head office. I extended the requirement to 14APR05.
Due 14 April 2005
Resolved 7 April 2005
Deck/Cargo › Vapor Control Systems › Fixed Vapor Collection Arms
Issued 14 March 2005 Resolved
Provide proof that the vapor control system (VCS) has been inspected and approved. Provide a copy of that letter (serial # C2-0306771) to the barge and keep onboard. Vessel restricted from using VCS until cleared.
Due 28 March 2005
Resolved 16 March 2005
Resolution: Operator provided vessel specific letter (serial # C2-0402522) via fax.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 14 March 2005 Resolved
Prove proper operation of stern light. This item shall be completed prior to operating at night.
Due 28 March 2005
Resolved 15 March 2005
Resolution: Operator called and stating that the stern light was operational. Operator followed up his phone call with a written and signed attestation that the stern navigation light was functioning properly.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Piping
Issued 14 March 2005 Resolved
Provide proof of all cargo piping and hose tests IAW 33CFR156.170.
Due 28 March 2005
Resolved 15 March 2005
Resolution: Operator provided the testing certificates from Bay Ship and Yacht Alameda.
Engineering › Compressed Air System (control) › Valve
Issued 14 March 2005 Resolved
Prove proper operation of pressure relief valve on air receiver in generator room.
Due 28 March 2005
Resolved 14 March 2005
Resolution: Operator corrected on the spot. The relief valve released at 135 psi.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 14 March 2005 Resolved
Provide required retroreflective tape for both ring buoys.
Due 28 March 2005
Resolved 14 March 2005
Lifesaving › Lifejacket/PFD (Type I) › Marking
Issued 14 March 2005 Resolved
Properly stencil the name of the vessel on both PFDs.
Due 28 March 2005
Resolved 14 March 2005
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 14 March 2005 Resolved
Provide proof of annual renewal of waterlight batteries or renew water light batteries.
Due 28 March 2005
Resolved 14 March 2005
Resolution: Operator renewed the waterlight batteries on the spot.
Electrical › Electric Generation Source (service)
Issued 31 March 2004 Resolved
Provide servicing report for generator verifying that tests of low lube oil & overspeed automatic shut-down have been conducted satisfactorily.
Due 30 April 2004
Resolved 1 April 2004
Deck/Cargo › Holds/Tanks
Issued 31 March 2004 Resolved
Prove proper operation of EMS Marcon high-level alarm indicators for all tanks so equipped. LEGACY COMPONENT DESC: Tank Level Monitoring Device
Due 30 April 2004
Resolved 8 April 2004

Casualty record · 6

25 May 2004Routine · role: Involved in a Marine Casualty · activity 2078419
2 November 2007Routine · role: Involved in a Marine Casualty · activity 3094240
30 October 2009Routine · role: Involved in a Marine Casualty · activity 3624934
30 October 2009Routine · role: Source Vessel for Cargo Transfer · activity 3624934
18 February 2011Routine · role: Involved in a Marine Investigation (non-casualty) · activity 3956947
29 September 2011Routine · role: Involved in a Marine Casualty · activity 4299581
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.