Records from 2007 to 2026. Most recent: inspection, 5 May 2026.
Documentation record
Registered dimensions (L × B × D)98.8 ft × 32.0 ft × 10.2 ft
Registered tonnagegross 320 / net 96
ITC dimensions (L × B × D)98.8 ft × 32.0 ft × 10.2 ft
ITC tonnagegross 320 / net 96
BuilderNEWSOUTH MARINE CONSTRUCTION INC · GREENVILLE, MS, UNITED STATES · built 2006
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portLAKE PROVIDENCE, LA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 5 August 2026 · expires 31 August 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it320 - Convention (Subpart B), Gross Ton
96 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 35
5 May 2026
Administrative Inspection · Damage Survey
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 8367550
18 February 2026
COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 8312325
1 September 2024
Type not recorded
No type recorded · Station New Orleans · USCG Heartland District (CGD-H) · Activity 7994511
26 January 2024
TPO Audit
Administrative · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 7856107
1 February 2023
Damage Survey
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 7630140
31 January 2023
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 7630369
7 September 2022
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7553840
6 September 2022
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7588088
12 August 2021
Type not recorded
No type recorded · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 7314463
3 April 2021
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7191210
14 July 2020
Type not recorded
No type recorded · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 7014962
16 June 2020
Initial Certification
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 7067627
15 January 2020
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6891531
25 April 2019
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 6670619
1 January 2019
Type not recorded
No type recorded · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 6605007
8 March 2018
Industry Initiated Exam
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 6376667
14 June 2014
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4890192
30 March 2014
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 4826839
19 March 2014
Type not recorded
No type recorded · Station Lake Charles · USCG Heartland District (CGD-H) · Activity 4824072
14 January 2014
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 4783641
28 July 2012
Type not recorded
No type recorded · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 4395445
9 June 2012
Type not recorded
No type recorded · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 4340540
29 January 2012
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 4234402
2 August 2011
Administration · Industry Initiated Exam
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 4104017
31 July 2011
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4135349
15 June 2011
Type not recorded
No type recorded · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 4046370
23 May 2011
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 4020945
7 July 2010
Type not recorded
No type recorded · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3789235
23 June 2010
Damage Survey
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3779266
23 June 2010
Type not recorded
No type recorded · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3807217
25 May 2010
Type not recorded
No type recorded · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3763815
4 August 2009
Administrative Inspection · Damage Survey
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3555372
30 July 2009
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3556151
16 March 2008
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 3165501
12 December 2007
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 3114248
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 5 May 2026
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions.
Vessel reported a fire to the port main engine. Vessel will request a surveyor from their TPO, ITOW, to conduct a damage assessment and report on the findings and submit to the USCG for review. Vessel is required to have an assist vessel to navigate to Terrel River Service in Lettsworth, LA for repairs.
46 CFR 143.205(a)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 May 2026
Resolution: Vessel rep provided objective evidence the deficiencies have been rectified.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 5 May 2026
Resolved
All seals and gaskets must be properly maintained to prevent leaks of flammable or combustible liquid, as those terms are defined in 46 CFR subpart 30.10, into the machinery space.
Surveyor will make assessment to the surrounding piping systems and connections for system integrity.
46 CFR 143.220(a)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 May 2026
Resolution: Vessel rep provided objective evidence the deficiencies have been rectified.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 5 May 2026
Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards.
Surveyor will make assessment on surrounding electrical systems and wiring for integrity.
46 CFR 143.400(a)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 May 2026
Resolution: Vessel rep provided objective evidence the deficiencies have been rectified.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 7 September 2022
Resolved
Propulsion machinery, including main engines must be maintained to ensure proper operation. ECM battery found dead. Vessel recharged spare battery and replaced. Vessel verified satisfactory operation.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 7 September 2022
Resolution: Verified vessel had spare battery and replaced inoperable battery.