Records from 1994 to 2026. Most recent: inspection, 6 August 2026.
Everything above is free. The detail below — the inspection history, the deficiency record, the tow units, the recorded names, the casualty record and the documentation record — is Professional, $39 a month. Sign in.
Inspection history · 54
6 August 2026
Annual Inspection · Vessel Attendance · MTSA Verification
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 8456765
8 August 2025
MTSA Verification · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 8205444
26 November 2024
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 8041935
23 September 2024
Deficiency Check
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 8007827
29 July 2024
COI Inspection · MTSA Verification · Examination of Repairs · Internal Structural Exam
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 7969912
31 May 2024
Internal Structural Exam · Drydock Exam · Examination of Repairs
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 7924235
18 April 2024
Construction Oversight
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 7897456
28 April 2023
Annual Inspection · MTSA Verification · Deficiency Check
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 7677430
4 April 2023
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 7720562
18 May 2022
Administrative Inspection
Administrative · Commandant (CG-CVC) · Activity 7453506
17 May 2022
Administrative Inspection
Administrative · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 7452581
9 March 2022
Administrative Inspection · Initial Certification · Deficiency Check
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 7408507
17 November 2021
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7353067
29 November 2020
Damage Survey
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 7103092
29 March 2020
Initial Certification · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6932906
5 November 2019
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6850805
30 September 2014
MTSA Verification · Industry Initiated Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4995904
22 February 2014
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 4994905
5 August 2013
Damage Survey
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 4676989
5 April 2013
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4566221
24 November 2012
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 4496194
17 July 2012
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4387818
17 July 2012
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4403593
17 July 2012
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4404930
19 June 2012
Industry Initiated Exam · MTSA Verification
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4350786
9 June 2012
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 4348011
21 April 2010
Industry Initiated Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3721650
7 April 2009
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3448225
28 November 2008
Deficiency Check
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3373636
28 November 2008
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3373701
10 September 2008
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3327377
26 December 2006
Administrative Inspection
Administrative · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 2846272
25 December 2006
Type not recorded
No type recorded · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 2847798
15 June 2006
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2695039
23 March 2005
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2317463
21 July 2004
MTSA Verification
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2140646
30 December 2003
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2000921
28 December 2003
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1973719
24 December 2003
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1990898
2 October 2003
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1929679
5 February 2003
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 1743534
4 May 2002
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1617677
7 April 2002
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 1614776
3 July 2000
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 146491
14 February 2000
Type not recorded
No type recorded · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 79389
7 June 1999
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 150374
20 May 1999
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 429006
11 April 1999
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 155586
28 November 1997
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 76204
28 January 1996
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 22886
28 November 1994
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 372943
19 September 1994
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 54294
29 April 1994
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 172843
11 February 1994
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 6654
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 29 September 2025
Resolved
A 40-B portable fire extinguisher must be located near the storage room or cabinet. Vessel did not have a 40-B fire extinguisher located near the flammable storage cabinet. Rectify with in 7 days.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 October 2025
Resolved 1 October 2025
Resolution: Vessel crew mounted a 40-B fire extinguisher near the storage locker compliant with applicable requirements.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 23 August 2024
Resolved
All installed bilge piping must have a check/foot valve in each bilge suction that prevents unintended backflooding through bilge piping. Bilge suctions in forward hold and engine room did not have check/foot valves installed in bilge piping.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 September 2024
Resolved 23 September 2024
Resolution: Check valves installed
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 23 August 2024
Resolved
Machinery must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. Piping for grid coolers (not currently in use) was found open ended, causing a flooding risk to the engine room in the event that the grid coolers would experience material failure. Permanently cap or close open ended piping.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 September 2024
Resolved 23 September 2024
Resolution: Old grid cooler openings properly blanked off
09 - Working and Living Conditions › 092 - Working Conditions › Cleanliness of engine room
Issued 28 April 2023
Resolved
All bilges and void spaces are to be kept free from accumulation of combustible and flammable materials and liquids. Remove oil from bilges near shaft seal discharge pumps.
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 May 2023
Resolved 18 May 2023
Resolution: Bilges cleaned.
09 - Working and Living Conditions › 092 - Working Conditions › Holds and tanks safety
Issued 28 April 2023
Resolved
All bilges and void spaces are to be kept free from accumulation of combustible and flammable materials and liquids. Remove diesel from bilge of forward hold and remove drain line from hose reel containment.
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 May 2023
Resolved 18 May 2023
Resolution: Diesel removed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 28 April 2023
Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards. Install blanks or breakers in open slots in starboard engine room breaker box.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 May 2023
Resolved 18 May 2023
Resolution: Blanks installed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 28 April 2023
Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards. Properly secure two dead end wires under wheelhouse console.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 May 2023
Resolved 18 May 2023
Resolution: Wiring secured.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 28 April 2023
Resolved
Each towing vessel must be equipped with a means to detect smoke in berthing spaces. 02 bunk rooms are missing smoke detectors.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 May 2023
Resolved 18 May 2023
Resolution: Detectors installed.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 28 April 2023
Resolved
Each towing vessel must have a reliable means to provide notification when an emergency condition. An alarm for high bilge levels must be provided. FWD hold bilge is not equipped with a high level alarm. Vessel will install alarm at next dry dock.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 April 2025
Resolved 23 August 2024
Resolution: Bilge alarm installed
Lifesaving
Issued 20 May 1999
Resolved
VESSEL MUST DISPLAY EMPLOYEE ASSISTANCE PROGRAM HOTLINE INFORMATION.
Condition: Unknown
Due 30 June 1999
Resolved 14 April 2020
Resolution: Deficiency is obsolete - 21 years old. 27JAN2020 ABS survey noted 00 nonconformities pertaining to this component
Lifesaving
Issued 20 May 1999
Resolved
VESSEL MUST MAINTAIN A LOG OF TESTS AND INSPECTIONS IAW 33CFR164.78(b).
Condition: Unknown
Due 20 June 1999
Resolved 14 April 2020
Resolution: Deficiency is obsolete - 21 years old. 27JAN2020 ABS survey noted 00 nonconformities pertaining to this component
Navigation
Issued 20 May 1999
Resolved
PROVE PROPER OPERATION OF NAV LIGHTS IN ACCORDANCE WITH THE NAVIGATION RULES OF THE ROAD.
Condition: Unknown
Due 20 June 1999
Resolved 14 April 2020
Resolution: Deficiency is obsolete - 21 years old. 27JAN2020 ABS survey noted 00 nonconformities pertaining to this component