DAMIAN WISE is a 2009 towing vessel. The Coast Guard has recorded 12 inspections since 2012, most recently in October 2025, along with 17 deficiencies and 4 casualty investigations between 2016 and 2023.
Records from 2012 to 2025. Most recent: inspection, 8 October 2025.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Towing Vessel class in Maury's sources begin in 1980.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
The counts in the strip above are the same counts; this table splits the inspections by
the kind of activity recorded. A blank resolution means none was recorded in this data; it
does not establish that a deficiency is outstanding. Years with a record are calendar
years in which a record exists, not years in service.
What Maury does not do.
Documentation record
Registered dimensions (L × B × D)65.0 ft × 26.0 ft × 9.5 ft
Registered tonnagegross 107 / net 86
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderGNOTS RESERVE INC · ST ROSE, LA, UNITED STATES · built 2009
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 27 March 2026 · expires 30 April 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it107 - Simplified, Gross Ton 86 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299
What it gives that this page does not: the whole record in one
dated, citable document — every line with its Coast Guard activity id, the retrieval
date on the cover, built to print to PDF with its page breaks — that a surveyor can
attach and a lender can file. The same facts as this page, complete and in one file.
Every recorded inspection, 1980 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
A request, not a checkout: leave an email and Maury replies once, with
the dated document for this hull and a Stripe invoice for $299. Nothing is charged before
the document is in your hands.
Used only to answer this request.
Not shared, not sold, and not added to a mailing list.
The Coast Guard recorded this vessel and the following in the same
inspection activity — normally a tug and the barges in its tow. A recreational or
unclassed hull in the same activity is held and not published, so it does not appear
here: these lists are a floor, not a complete manifest.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 13 August 2024Resolved
The Fuel shut off valve must be operable from a safe place outside the space where the valve is installed. MI's observed both PORT and STBD shut off valves inoperable. 46 CFR 143.260.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 13 August 2024
Resolution: Corrected prior to end of inspection.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 3 August 2023Resolved
The master must ensure that all hatches, doors, and other openings designed to be watertight or weather-tight function properly. STBD porthole in galley is cracked.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 17 August 2023
Resolution: Vessel had broken porthole replaced.
14 - Pollution Prevention › 142 - MARPOL Annex II › Tank washing equipment
Issued 3 August 2023Resolved
The instructions supplied by the manufacturer must contain directions for each of the following:(5) The type and quantity of chemicals that are required to operate the device, including instructions on the proper handling, storage and use of these chemicals. Vessel did not have spare chlorine tablets.
Action required: 10 - Deficiency Rectified
Resolved 3 August 2023
Resolution: Added spare chlorine tablets to vessel
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 3 August 2023Resolved
Emergency lighting must be provided for all internal crew working and living areas. Emergency lighting sources must provide for sufficient illumination under emergency conditions to facilitate egress from each space and must be either: (1) Automatic, battery-operated with a duration of no less than 2 hours; or (2)Non-electric, phosphorescent adhesive lighting strips that are installed along escape routes and sufficiently visible to enable egress with no power. Found vessel to have no emergency lighting or phosphorescent adhesive
lighting strips in the main deck head.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 4 August 2023
Resolution: Attached phosphorescent exit sign to the door of the head.
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 3 August 2023Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. Vessel’s emergency means of access to fuel shutoff values was missing from the vessel. Must replace emergency hammer to break glass to access the fuel shutoff valves.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 3 August 2023
Resolution: Added and attached hammer to system.
10 - Safety of Navigation › N/A - No Subsystem › Rudder angle indicator
Issued 3 August 2023Resolved
Each towing vessel must have a means to monitor and control the amount of thrust, rudder angle, and direction of thrust, at each operating station. Vessel’s rudder angle indicator was inoperable during the steering test. Vessel corrected on the spot.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 8 September 2022Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards. MI found Steering motors windings dirty and fan blade broken.46CFR143.400(a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 September 2022
Resolved 22 September 2022
Resolution: Received and reviewed documenation and photos of newly replaced and installed fan blade and cleaned steering motor windings.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 8 September 2022Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. MI found the water heater safety relief valve not aimed into bilge.46CFR143.205(a)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 September 2022
Resolved 20 September 2022
Resolution: Recieved and reviewed photos of newly installed piping of relief valve into bilge.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 8 September 2022Resolved
Propulsion machinery, including main engines, reduction gears, shafting, bearings, and electrical equipment and systems, must: Have suitable propulsion controls to provide the operator full control at each operating station. MI found. Stbd / Port MDE control air hose dry rotting. 46CFR143.205(c)(3)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 September 2022
Resolved 20 September 2022
Resolution: Vessel replaced all dry rotted air hoses. Recieved and reviewed satisfactory photos.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 8 September 2022Resolved
All seals and gaskets must be properly maintained to prevent leaks of flammable or combustible liquid, as those terms are defined in 46 CFR subpart 30.10, into the machinery space. MI found the Glass tubes missing on fuel tank level indicators on the P/S fuel tanks.46CFR143.220 (a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 September 2022
Resolved 20 September 2022
Resolution: Received and reviewed satifactory photos of capped off sight glass tubes.
The owner or managing operator must implement procedures to identify and mitigate health and safety hazards, including but not limited to:(6) Blood-borne pathogens and other biological hazards. Vessel did not have materials listed for blood-borne pathogens onboard.46CFR140.510(a)(6)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 October 2022
Resolved 20 September 2022
Resolution: Received and reviewed photos of newly installed bloodborne pathogen kit IAW vessel's health and safety plan.
Portable and semi-portable fire extinguishers must be inspected, maintained, and tested in accordance with the inspection, maintenance procedures, and hydrostatic pressure tests required by Chapters 7 and 8 of NFPA 10, with the frequency specified by NFPA 10 and as amended here: Monthly inspections required by NFPA 10 may be conducted by the owner, operator, person-in-charge, or a
designated member of the crew. Vessel did not have
records of monthly fire fighting inspections. Record monthly inspections. 46CFR142.240(a)(1)(ii)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 October 2022
Resolved 20 September 2022
Resolution: Received satisfactory records of monthly fire fighting inspections and newly formatted documents for further monthly inspections.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 8 September 2022Resolved
Essential systems or equipment must be regularly tested and examined. Tests and examinations must verify that the system or equipment functions as designed. If a component is found unsatisfactory, it must be repaired or replaced. MI found STBD Steering ram pin excessively loose.46CFR 143.245
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 October 2022
Resolved 20 September 2022
Resolution: Received and reviewed satisfactory photos of renewed dead head for STBD steering ram.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 8 September 2022Resolved
Hydraulic steering fluid pressure, if the vessel is equipped with hydraulic steering systems. MI found improper Steering pump gauges. Replace gauges to scale.46CFR143.230(c)(5)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 October 2022
Resolved 31 October 2022
Resolution: Received documentation from vessel from Custom Hydraulic Components, Inc stating that hydraulic steering system can reach up to 1350PSI therefore a 3000PSI gage is appropriate.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 8 September 2022Resolved
Piping and machinery components that exceed 220 °C (428 °F), including fittings, flanges, valves, exhaust manifolds, and turbochargers, must be insulated. Measures must be in place to prevent flammable or combustible liquid piping leaks from coming into contact with these components. MI found one section of exhaust lagging not connected with moussing wire on STBD MDE.46CFR 143.220
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 8 September 2022
Resolution: MI observed crew re-attach exhaust lagging with moussing wire on STBD MDE.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 8 September 2022Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. Port SSDG fuel leak found and rectified.46CFR143.205 (a)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 8 September 2022
Resolution: MI observed crew tighten fuel line on Port SSDG to secure fuel oil leak.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 8 September 2022Resolved
Cylinders must always be secured and, when not in use, they must be stowed in a rack in an upright position, with the valve protection cap in place. Vessel had 01 cylinder bottles of compressed gas stowed on deck and unsecured. Vessel rep secured bottle satisfactory in presence of MI.46CFR147.60(b)(1)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 8 September 2022
Resolution: MI observed compressed air bottle properly stowed and secured onboard vessel.
24 May 2016Routine · role: Transiting Vicinity of Primary Subject · serious marine incident, as classified · activity 5917591
20 February 2020Routine · role: Moored/Anchored in Vicinity of Primary Subject · serious marine incident, as classified · activity 6923074
15 August 2021Routine · role: Sighted in Area · activity 7288359
18 February 2023Routine · role: Transiting Vicinity of Primary Subject · activity 7641548
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.