Inspection history · 75
13 March 2026
Drydock Exam · Examination of Repairs · COI Inspection · Internal Structural Exam · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8325882
28 April 2025
Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8099967
19 March 2025
Administrative Inspection · Deficiency Check · Examination of Repairs
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8096195
5 June 2024
Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7930521
13 May 2024
Annual Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7911626
18 October 2023
Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7810785
18 October 2023
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7818851
8 May 2023
Annual Inspection · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7683697
29 April 2022
Administrative Inspection · Annual Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7440536
8 April 2021
Initial Certification · MTSA Verification · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7171088
7 December 2020
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7107845
4 December 2020
In-Service Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7106126
31 May 2020
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6966510
30 January 2020
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6908085
30 January 2020
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6932489
24 May 2019
Initial Certification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6692339
21 September 2018
Type not recorded
No type recorded · Station Freeport · USCG Heartland District (CGD-H) · Activity 6545928
11 September 2018
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6607837
23 April 2018
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6398735
5 March 2018
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6367426
20 July 2017
Industry Initiated Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6211806
23 January 2016
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6092970
28 May 2014
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4877694
8 October 2013
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4734838
18 June 2013
MTSA Verification · Industry Initiated Exam · DAPI Audit
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4630237
9 July 2012
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4373076
17 February 2012
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4249874
1 December 2011
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4199136
23 August 2011
MTSA Verification · Deficiency Check · DAPI Audit · Industry Initiated Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4124970
9 January 2010
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3662748
9 November 2009
Type not recorded
No type recorded · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3630630
12 September 2009
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3610729
8 September 2009
Type not recorded
No type recorded · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3591644
6 January 2009
Type not recorded
No type recorded · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3389501
5 January 2009
Damage Survey
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3388949
5 January 2009
Administration
Administrative · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3389092
9 December 2008
Administration
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3380748
14 December 2007
Type not recorded
No type recorded · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3116816
7 August 2007
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3026677
7 January 2007
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2909670
14 April 2006
Type not recorded
No type recorded · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 2634626
16 August 2004
MTSA Verification
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2167878
4 March 2004
Administrative Inspection
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2018243
9 January 2004
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1983011
29 December 2003
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1974857
11 December 2003
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1964271
18 November 2003
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2065985
15 August 2003
Uninspected Towing Vessel
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1883989
22 May 2002
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1619400
16 April 2002
Annual Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1606789
5 April 2002
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1611633
16 March 2001
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 24192
30 December 2000
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 188340
25 September 2000
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 12640
23 July 2000
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 161038
15 April 1999
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 427890
29 March 1999
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 112495
24 March 1999
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 427815
14 June 1998
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 110425
6 June 1998
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 161688
3 May 1998
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 182731
27 January 1997
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 400034
7 June 1996
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 217645
4 May 1996
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 97761
14 April 1996
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 166522
4 March 1996
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 16966
4 March 1996
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 108844
16 January 1996
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 386976
23 October 1995
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 144964
14 March 1995
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 187894
12 August 1994
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 80204
7 June 1993
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 358768
27 March 1993
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 165482
1 February 1993
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 661712
27 January 1993
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 500838
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 28 April 2025
Resolved
At least two lifebuoys on a towing vessel greater than 26 feet must be fitted with a floating electric water light approved under approval series 161.010 or 161.110.
Marine Inspector identified a lifebuoy on the upper deck with an inoperable light.
Vessel shall replace the battery and ensure functionality of the light.
46 CFR 141.360(b)(2)
16c
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 May 2025
Resolved 13 May 2025
Resolution: MI witnessed sat functioning on board.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 28 April 2025
Resolved
Each lifebuoy on a towing vessel must be marked in block capital letters with the name of the vessel.
MI identified a lifebuoy on the port main deck with worn lettering.
Re-apply the vessel's name to the lifebuoy.
46 CFR 141.360(1)(4)
16c
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 May 2025
Resolved 13 May 2025
Resolution: MI witnessed sat lettering on board.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 28 April 2025
Resolved
Each towing vessel must be equipped with an industrial type first aid cabinet or kit, appropriate to the size of the crew and operating conditions.
MI identified an expired first aid kit.
Replace the first aid kit.
46 CFR 140.435
16c
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 May 2025
Resolved 13 May 2025
Resolution: MI witnessed sat replacement on board.
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 28 April 2025
Resolved
Each towing vessel must have a reliable means to provide notification when an emergency condition exists or an essential system develops problems that require attention. The following systems must be equipped with gauges at the machinery location: Main engine lubricating oil pressure, RPM, cooling water temp.
MI identified multiple faults on the bridge main engine alarm display as well as inoperable gauges in the engine room.
1. Port main engine local display inoperable
2. Starboard main engine local RPM gauge inoperable
3. Reduction gear active fault
4. Main alarm panel shows multiple active main engine/reduction gear alarms
Address and rectify the alarms on the operating panel on the bridge and ensure functionality of the gauges in the engine room.
46 CFR 143.230
16c
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 May 2025
Resolved 13 May 2025
Resolution: MI witnessed sat functioning of alarm panels on bridge and in engine room.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 13 May 2024
Resolved
An existing vessel may be deemed by the OCMI, or TPO, to be in compliance with this subpart provided that either:(a) The vessel is built, equipped, and maintained to conform to the rules of a recognized classification society appropriate for the intended service and routes, but not classed.
Damage to multiple vertical frames and bent tripping brackets observed in starboard machinery space. Vessel to enact permanent repairs to damaged frames during next scheduled internal structural exam but no later than April 30, 2026 to satisfaction of the CG.
46 CFR 144.200
Action required: 705 - Other - as specified
Due 30 April 2026
Resolved 20 March 2025
Resolution: See attached plate summary.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 13 May 2024
Resolved
Decks and bulkheads designed to be watertight or weathertight must be maintained in that condition.
Multiple penetrations observed in port side battery room below pilot house. Properly repair and seal holes.
46 CFR 140.610(f)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 May 2024
Resolved 5 June 2024
Resolution: Marine inspectors attended vessel and verified all holes were sealed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 13 May 2024
Resolved
Electrical connections must be suitably installed to prevent them from coming loose through vibration or accidental contact.
Observed loose solenoid on starboard generator that was being held together by zip ties and had multiple loose wires protruding posing an electrical hazard.
46 CFR 143.400(e)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 May 2024
Resolved 5 June 2024
Resolution: Marine inspectors attended vessel and observed solenoid was properly mounted and wired.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 13 May 2024
Resolved
Each towing vessel must be equipped with a means to detect smoke in the berthing spaces and lounges that alerts individuals in those spaces. This may be accomplished by an installed detection system, or by using individual battery-operated detectors meeting UL 217.
Observed multiple smoke detectors throughout vessel that did not meet UL 217 standards or equivalent.
46 CFR 142.330(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 May 2024
Resolved 5 June 2024
Resolution: All smoke detectors were replaced with UL 217 rated equipment.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 13 May 2024
Resolved
Propulsion machinery, including main engines, reduction gears, shafting, bearings, and electrical equipment and systems, must:(1) Be maintained to ensure proper operation.
Observed broken water temperature gauge on port main engine and excessive corrosion on pipe and missing hardware.
46 CFR 143.205(c)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 May 2024
Resolved 5 June 2024
Resolution: Broken gauge was removed and hardware replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 13 May 2024
Resolved
Each lifebuoy on a towing vessel must:(4) Be marked in block capital letters with the name of the vessel.
Observed multiple lifebuoys that need to be re-stenciled with the name of the vessel to make them legible.
46 CFR 141.360(b)(4)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 May 2024
Resolved 5 June 2024
Resolution: All lifebuoys were repainted.
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 4 December 2020
Resolved
Piping and tanks exposed to the outside of the hull must be made of metal and maintained in a leak free condition. Vessel reported crack on starboard side fule tank. Repairs will be inspected to the satisfaction of a Coast Guard Inspector.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 December 2020
Resolution: Satisfactory repair attested to by yard representative, TPO in agreement
Engineering › Steering Gear System › Rudder
Issued 5 January 2009
Resolved
Lost the STBD rudder from the vessel at MM388 in the ICW going west bound.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 28 January 2009
Resolution: Received FAX of repairs conducted on vessel.
Accommodation/Occupational Safety
Issued 24 March 1999
Resolved
Vessel did not have a Waste Management Plan on board.
Condition: Unknown
Due 24 March 1999
Resolved 3 August 2017
Resolution: Part of AWO Responsible Carrier Operations Manual kept in wheelhouse and vessel personnel are instructed in its compliance.
Navigation
Issued 27 January 1997
Resolved
VSL COPY OF INLAND NAV RULES OUTDATED.
Condition: Unknown
Due 27 February 1997
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Construction/Loadline
Issued 27 January 1997
Resolved
VSL NAME AND HAILING PORT NOT ON STERN.
Condition: Unknown
Due 27 February 1997
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Navigation
Issued 27 January 1997
Resolved
VSL DID NOT HAVE CURRENT CHARTS, LIGHT LIST OR RIVER-CURRENT TABLES ON BOARD.
Condition: Unknown
Due 27 February 1997
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Documentation
Issued 27 January 1997
Resolved
LOG ENTRIES REQUIRED BY 33 CFR 164.78(b) NOT MADE.
Condition: Unknown
Due 27 February 1997
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Documentation
Issued 27 January 1997
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 27 February 1997
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past