Records from 2006 to 2026. Most recent: inspection, 2 July 2026.
Documentation record
Registered dimensions (L × B × D)297.5 ft × 54.0 ft × 12.0 ft
Registered tonnagegross 1,619 / net 1,619
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderJEFFBOAT LLC · JEFFERSONVILLE, IN, UNITED STATES · built 2006
Hull materialSteel
PropulsionUNSPECIFIED
Hull shapeBox
Hull configurationMonohull
Hailing portHOUSTON, TX
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 11 February 2026 · expires 31 March 2027
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it1619 - Simplified, Gross Ton
1619 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 41
2 July 2026
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8426132
2 July 2026
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8426599
30 June 2026
COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8401506
18 May 2026
Cargo Tank Internal · Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8373015
13 March 2026
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8325620
13 March 2026
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8325823
22 July 2024
MTSA Verification · Periodic Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7960383
4 August 2023
Administrative Inspection · Examination of Repairs · Deficiency Check
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7760458
30 August 2021
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7335095
28 June 2021
COI Inspection · Examination of Repairs · Administrative Inspection · MTSA Verification · Internal Structural Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7235752
11 March 2021
Deficiency Check · Examination of Repairs
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 7154188
11 May 2020
Administrative Inspection · Deficiency Check · Damage Survey
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6951196
10 May 2020
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6956520
22 July 2019
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6755172
14 August 2018
MTSA Verification · Periodic Inspection · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6511936
15 August 2017
Administrative Inspection · Annual Inspection · MTSA Verification
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6241555
12 May 2017
Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6146724
23 May 2016
Hull Examination · COI Inspection · Internal Structural Exam · Cargo Tank Internal · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5884047
18 August 2015
Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 5220255
20 June 2014
Administrative Inspection
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 4894455
17 June 2014
Periodic Inspection · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 4891135
29 May 2014
Examination of Repairs · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 4878491
2 May 2014
Administrative Inspection · Damage Survey
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 4850870
30 April 2014
Damage Survey · Administrative Inspection
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 4848020
24 March 2014
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4830798
16 July 2013
Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4655242
24 August 2012
Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4421045
6 August 2012
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4398685
16 July 2012
Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4381076
9 July 2012
Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4373342
4 July 2012
Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4403997
9 March 2012
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4260263
12 January 2010
MTSA Verification · Periodic Inspection
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 3667182
18 February 2009
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3419688
29 January 2009
Deficiency Check · Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3403833
9 October 2008
Damage Survey
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3341403
9 October 2008
Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3425468
6 March 2008
MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3158067
1 February 2007
Type not recorded
No type recorded · Marine Safety Detachment Greenville · USCG Heartland District (CGD-H) · Activity 2865966
12 December 2006
Cargo Tank Internal · Initial Certification · MTSA Verification · Hull Examination · Internal Structural Exam
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 2838666
3 November 2006
Security Plan Amendment Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 2813695
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 2 July 2026
Resolved
All tank vessels, the construction or conversion of which is started on or after July 1, 1951, shall conform to the requirements in this subpart in construction of hulls.
Sector New Orleans Duty Marine Inspector received notification of a hole in the #3P cargo tank top.
Vessel is required to submit a transit plan and affect permanent repairs once discharge of the cargo tank is completed.
46 CFR 32.60-1(a)
Action required: 705 - Other - as specified
Resolved 21 July 2026
Construction/Loadline › Hull › Bottom Plating
Issued 2 May 2014
Resolved
An inset in the #5 port wing tank bottom plating was noted. The inset is between 0-1" and is approx. 5' forward of the aft bulkhead extending forward approx 8', and beginning approx. 4' to the port of centerline and extending to port approx 3'. Two (2) bottom angles were mildly distorted. Crop and renew damaged area.
Action required: 705 - Other - as specified
Resolved 4 June 2014
Resolution: Conducted examination of all permanent repairs, see activity 4878491 for details. All repairs were made to the satisfaction of the attending Coast Guard Marine Inspector.
Construction/Loadline › Hull › Bottom Plating
Issued 2 May 2014
Resolved
An inset in the #5 starboard wing tank bottom plating was noted. The inset is between is 0-1" and starts at the aft bulkhead extending forward approx 11', and beginning approx 5' to the starboard of centerline and extending to starboard approx 3'. One (1) bottom angle was mildly distorted. Crop and renew damaged area.
Action required: 705 - Other - as specified
Resolved 4 June 2014
Resolution: Conducted examination of all permanent repairs, see activity 4878491 for details. All repairs were made to the satisfaction of the attending Coast Guard Marine Inspector.
Construction/Loadline › Hull › Bottom Plating
Issued 2 May 2014
Resolved
An inset in the stern void bottom plating was noted. The inset is 0-1.5" and starts at the transverse bilge knuckle extending forward approx 7' and beginning at the port longitudinal bilge knuckle extending to starboard approx 7' 4". Three (3) bottom angles were mildly distorted. Crop and renew damaged area.
Action required: 705 - Other - as specified
Resolved 4 June 2014
Resolution: Conducted examination of all permanent repairs, see activity 4878491 for details. All repairs were made to the satisfaction of the attending Coast Guard Marine Inspector.
Construction/Loadline › Hull › Transverse Frame
Issued 2 May 2014
Resolved
In the #5 port wing tank, the first and second transverse floor frames forward of the aft bulkhead were buckled for approx 4'. Crop and renew damaged area.
Action required: 705 - Other - as specified
Resolved 4 June 2014
Resolution: Conducted examination of all permanent repairs, see activity 4878491 for details. All repairs were made to the satisfaction of the attending Coast Guard Marine Inspector.
Construction/Loadline › Hull › Transverse Frame
Issued 2 May 2014
Resolved
In the #5 starboard wing tank, the first transverse floor frame forward of the aft bulkhead was buckled for approx 4'. Crop and renew damaged area.
Action required: 705 - Other - as specified
Resolved 4 June 2014
Resolution: Conducted examination of all permanent repairs, see activity 4878491 for details. All repairs were made to the satisfaction of the attending Coast Guard Marine Inspector.
Construction/Loadline › Hull › Bottom Plating
Issued 30 April 2014
Resolved
Noted an approx 6' x 12' x 3" inset in bottom plating located in the 4S void ivo aft ladder. 6 - 4" x 3" bottom angles are bowed in this area.
Action required: 705 - Other - as specified
Resolved 2 May 2014
Resolution: Examined bottom plating in drydock. Noted slight inset (3/4" over an 8 foot section), but nothing requiring repair. No other damage noted.
Construction/Loadline › Hull › Longitudinal Frame
Issued 30 April 2014
Resolved
Noted multiple weld fractures in all voids. All fractures were located where the side longitudinals are welded to verticle framing.
Action required: 705 - Other - as specified
Resolved 4 June 2014
Resolution: Conducted examination of all permanent repairs, see activity 4878491 for details. All repairs were made to the satisfaction of the attending Coast Guard Marine Inspector.
Construction/Loadline › Structures › Scuttle
Issued 29 January 2009
Resolved
Properly install number one port hatch gasket.
Action required: 705 - Other - as specified
Due 28 February 2009
Resolved 2 February 2009
Deck/Cargo › Cargo Heating › General
Issued 29 January 2009
Resolved
Properly conduct test of high temperature alarm/shutdown of thermal fluid heater.
Action required: 705 - Other - as specified
Due 28 February 2009
Resolved 18 February 2009
Resolution: Alarm/shutdown for thurmal fluid heater tested properly.
Deck/Cargo › Cargo Stowage › General
Issued 29 January 2009
Resolved
Properly remove cargo from portside overflow containment.
Action required: 705 - Other - as specified
Due 28 February 2009
Resolved 18 February 2009
Resolution: Port overflow containment cargo pumped out.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Pump
Issued 19 December 2006
Resolved
Vessel owners are to prove that both cargo pump engine units are in complete compliance with 46 CFR 111.105-31(l).
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 1 August 2007
Resolved 23 May 2016
Resolution: Witnessed operation of approved wire harness and alternator for Class 1, Div 1 area.